  • Helical 3D DSA for Whole-Head-and-Neck Vascular Imaging: Technical Development and First-in-Human Application

    by Yingkun He, Mengqi Li, Yaping Wu, Yao Tang, Weilong Mao, Baolin Mao, Qingfang Wang, Huikai Liu, Yang Yang, Ranran Ban, et al.

    A helical scanning trajectory extended the longitudinal coverage of three-dimensional (3D) digital subtraction angiography, enabling 3D angiography from the aortic arch to the cranial vertex using a robotic C-arm system.


  • Multistage Dual-Domain Networks With Informative Prior and Self-Augmentation for Dual-Energy Limited-Angle CT Reconstruction

    by Guojun Zhu, Yikun Zhang, Weilong Mao, Shiyu Zhu, Yan Xi, Guotao Quan, Gouenou Coatrieux, Xu Ji, Shipeng Xie, Yang Chen

    Dual-energy computed tomography (DECT) plays a crucial role in clinical practice due to its capabilities in material identification and quantification. However, complete DECT scans expose patients to additional radiation. To mitigate such a problem, one method is to reduce the CT scan angular range, which may cause limited-angle artifacts. This work utilized Multi-stage dual-domain networks (MsDu-Nets) for dual-energy limited-angle reconstruction that only requires a 180-degree scan. MsDu-Nets consists of multiple stages, where data processing is performed in both the sinogram domain and image domain within each stage. A filtered back projection (FBP) module is used to connect these two domains. MsDu-Nets leveraged the informative prior obtained by directly concatenating the dual-energy projection data, and directly reconstructing it after applying Parker Weights, which helps the network focus more on anatomical information. Self-augmentation is also employed to mitigate the streak artifacts introduced by the informative prior and enables the transmission of original information across stages. Comparison experiments and material decomposition experiments demonstrate that the proposed method is capable of obtaining high-quality dual-energy reconstructed images. The ablation experiments also validate the roles of different modules or components of the method.


  • Coarse-to-Fine Learning for Planning CT-Enhanced Limited-Angle CBCT Reconstruction

    by Shizhe Zang, Yikun Zhang, Dianlin Hu, Weilong Mao, Xuanjia Fei, Xu Ji, Yi Yao, Chunfeng Yang, Gouenou Coatrieux, Yang Chen

    In image-guided radiation therapy, the on-board cone-beam computed tomography (CBCT) is usually used for volumetric imaging and the limited-angle scanning protocol is often adopted to avoid the possible collisions of the moving gantry with patients and devices. However, images directly reconstructed using incomplete projection data may suffer from severe artifacts, which cannot provide precise guidance for the following therapeutic procedures. Compared with CBCT, the planning CT (pCT) acquired for the treatment plan can provide high-quality images of the same patient, showing the potential to improve the limited-angle CBCT. In this context, we propose a Multi-dimensional Joint Cascaded Network (MJCNet) which can exploit the prior information from pCT. MJCNet improves the imaging quality of limited-angle CBCT through a coarse-to-fine strategy. In the coarse restoration stage, a 2D network with two encoders that could extract and exploit the information of pCT is used to remove limited-angle artifacts slice-by-slice. In the fine-tuning stage, a 3D network with dense attention mechanism is employed to further improve the image details and remove the inter-slice artifacts. The real data from different parts of human bodies are collected to evaluate the proposed method. Experimental results demonstrate the promising performance of MJCNet in reducing wedge artifacts, restoring image structures and correcting HU numbers.


  • Prior Image-Constrained Iterative Reconstruction With Adaptive Step Size for Limited-Angle CBCT

    by Yiyuan Tao, Zhizhou Zhang, Dianlin Hu, Zhan Wu, Weilong Mao, Guojun Zhu, Xuanjia Fei, Xu Ji, Yikun Zhang, Shipeng Xie, et al.

    Cone-beam computed tomography (CBCT) has been widely used in image-guided radiotherapy (IGRT). In order to avoid the possible collisions of the moving gantry with patients and devices, the limited-angle scanning protocol is often adopted for CBCT. However, the missing views of projection data will induce severe wedge artifacts to the reconstructed images, having a negative influence on the following therapeutic procedures. Compared to limited-angle CBCT images, the planning CT images (pCT) acquired earlier for the same patient are artifact-free, which has the potential to improve the quality of limited-angle CBCT. In this context, this article proposes the prior image-constrained adaptive step size iterative reconstruction (PICAS) method. PICAS builds on prior image-constrained compressed sensing (PICCS) but is improved after taking into account the characteristics of IGRT. In PICAS, the high-quality pCT images are regarded as prior images to enhance the performance in artifact removal. To address the mismatch between pCT images and CBCT images, the pCT images are reprojected and reconstructed using the same imaging geometry as CBCT. Then, a transformation matrix between the pseudo-limited-angle pCT images and limited-angle images is obtained and it is further applied to the high-quality pCT images to generate the artifact-free prior images. In addition, an adaptive gradient descent (GD) optimization based on convex set projection and Lipschitz constant is adopted to accelerate the convergence of the algorithm. The proposed PICAS algorithm has been evaluated on the real data from different parts (head, lung, and abdomen) and under the limited-angle configurations with different scanning ranges (80°, 100°, and 120°). Qualitative and quantitative results demonstrate that PICAS has the potential to quickly reconstruct high-quality CBCT images in limited-angle scanning scenes, and thereby improve the accuracy of radiotherapy and shorten the time of surgery.


  • SeNAS-Net: Self-Supervised Noise and Artifact Suppression Network for Material Decomposition in Spectral CT

    by Xu Ji, Yuchen Lu, Yikun Zhang, Xu Zhuo, Shengqi Kan, Weilong Mao, Gouenou Coatrieux, Jean-Louis Coatrieux, Guotao Quan, Yan Xi, et al.

    For material decomposition in spectral computed tomography, the x-ray attenuation coefficient of an unknown material can be decomposed as a combination of a group of basis materials, in order to analyze its material properties. Material decomposition generally leads to amplification of image noise and artifacts. Meanwhile, it is often difficult to acquire the ground truth values of the material basis images, preventing the application of supervised learning-based noise reduction methods. To resolve such problem, we proposed a self-supervised noise and artifact suppression network for spectral computed tomography. The proposed method consists of a projection-domain self-supervised denoising network along with physics-driven constraints to mitigate the secondary artifacts, including a noise modulation item to incorporate the anisotropic noise amplitudes in the projection domain, a sinogram mask image to suppress streaky artifacts and a data fidelity loss item to further mitigate noise and to improve signal accuracy. The performance of the proposed method was evaluated based on both numerical experiment tests and laboratory experiment tests. Results demonstrated that the proposed method has promising performance in noise and artifact suppression for material decomposition in spectral computed tomography. Comprehensive ablation studies were performed to demonstrate the function of each physical constraint.


  • Image Domain Multi-Material Decomposition Noise Suppression Through Basis Transformation and Selective Filtering

    by Xu Ji, Xu Zhuo, Yuchen Lu, Weilong Mao, Shiyu Zhu, Guotao Quan, Yan Xi, Tianling Lyu, Yang Chen

    Spectral CT can provide material characterization ability to offer more precise material information for diagnosis purposes. However, the material decomposition process generally leads to amplification of noise which significantly limits the utility of the material basis images. To mitigate such problem, an image domain noise suppression method was proposed in this work. The method performs basis transformation of the material basis images based on a singular value decomposition. The noise variances of the original spectral CT images were incorporated in the matrix to be decomposed to ensure that the transformed basis images are statistically uncorrelated. Due to the difference in noise amplitudes in the transformed basis images, a selective filtering method was proposed with the low-noise transformed basis image as guidance. The method was evaluated using both numerical simulation and real clinical dual-energy CT data. Results demonstrated that compared with existing methods, the proposed method performs better in preserving the spatial resolution and the soft tissue contrast while suppressing the image noise. The proposed method is also computationally efficient and can realize real-time noise suppression for clinical spectral CT images.


  • Data-consistent Unsupervised Diffusion Model for Metal Artifact Reduction

    by Zhan Tong, Zhan Wu, Yang Yang, Weilong Mao, Shijie Wang, Yinsheng Li, Yang Chen

    Computed Tomography (CT) is an imaging technique widely used in clinical diagnosis. However, high-attenuation metallic implants result in the obstruction of low-energy Xrays and further lead to metal artifacts in the reconstructed CT images. Deep supervised model-based metal artifact reduction(MAR) approaches are limited in clinical applications due to the difficulty in obtaining paired artifact-affected and artifactfree data. Furthermore, these model-based methods lack the consideration of data consistency in the sinogram-domain to perform exact metal trace inpainting. To address these challenges, we propose a Data-consistent unsupErVised diffusiOn model for meTal artifact rEDuction, called DEVOTED-Net. First, DEVOTED-Net leverages prior knowledge to guide the conditional diffusion model for fine-grained metal trace inpainting. Second, an unsupervised MAR framework is designed in the reverse process for the unknown metal traces restoration in the sinogram domain. Third, to further enhance the sinogram-domain data consistency, physics-based consistency constraint loss including conjugateray consistency loss and accumulation-ray consistency loss is designed. Extensive experiments are carried out to verify the performance of our algorithm on the publicly available dataset and clinical experimental dataset. This efficient, accurate, and reliable MAR approach holds great potential in clinics.