Adriano Roberto Vieira de Sousa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Adriano Roberto Vieira de Sousa has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Eduardo Anunciação
Universidade Federal de Goiás, Escola de Agronomia, Instituto de Ciências Biológicas, Goiânia, Goiás, Brazil
2 shared publications - Elisângela de Paula Silveira-Lacerda
Center for the Study and Research of (Re)Emerging Agents, Federal University of Goiás, Goiânia, Brazil
2 shared publications - Marco Túlio Antônio Garcia-Zapata
Department of Tropical Medicine and Dermatology, Federal University of Goiás, Goiânia, Brazil
2 shared publications Carlos Eduardo Anunciação
UFG: Universidade Federal de Goias
1 shared publication- Elisangela Gomes da Silva
Univ Fed Goias, Inst Ciencias Biol, Goiania, GO, Brazil
1 shared publication Elisângela de Paula Silveira Lacerda
UFG: Universidade Federal de Goias
1 shared publication
Latest Publications
- Open Access
- 31 March 2025
- Published by Springer Nature in Research Square
Arboviruses Wastewater Surveillance in Brazil’s Midwest Region: Extending a Predictive Web Application
Arboviruses pose significant public health challenges in Brazil's Midwest, highlighting the need for effective surveillance for early outbreak detection. Although wastewater monitoring is increasingly recognized as an epidemiological tool, integration with clinical data remains limited. This study enhances a predictive web application by combining molecular wastewater surveillance with clinical epidemiological records. Monthly wastewater samples from 2023 were concentrated via polyethylene glycol precipitation and analyzed by RT-qPCR for arbovirus RNA. Results revealed arboviral RNA in 92% of samples, with detection rates of 31% for dengue (DENV), 39% for Zika (ZIKV), and 17% for chikungunya (CHIKV). Molecular findings closely matched clinical reports, supporting wastewater surveillance as a reliable arbovirus monitoring tool. The updated web application offers timely predictions and effective public health interventions, improving preparedness and response to arbovirus outbreaks.
- 31 March 2025
- Published by Springer Nature in Research Square
Open AccessArboviruses Wastewater Surveillance in Brazil’s Midwest Region: Extending a Predictive Web Application
Arboviruses pose significant public health challenges in Brazil's Midwest, highlighting the need for effective surveillance for early outbreak detection. Although wastewater monitoring is increasingly recognized as an epidemiological tool, integration with clinical data remains limited. This study enhances a predictive web application by combining molecular wastewater surveillance with clinical epidemiological records. Monthly wastewater samples from 2023 were concentrated via polyethylene glycol precipitation and analyzed by RT-qPCR for arbovirus RNA. Results revealed arboviral RNA in 92% of samples, with detection rates of 31% for dengue (DENV), 39% for Zika (ZIKV), and 17% for chikungunya (CHIKV). Molecular findings closely matched clinical reports, supporting wastewater surveillance as a reliable arbovirus monitoring tool. The updated web application offers timely predictions and effective public health interventions, improving preparedness and response to arbovirus outbreaks.
- 6 May 2024
- Published by Springer Nature in Brazilian Journal of Microbiology
- Vol. 55 (2) , 1801-1809
Diagnostic performance of the bioline dengue duo rapid test on symptomatic patients assisted at Armed Forces Hospital (Hfa) in Brasília, Brazil
Dengue necessitates accurate diagnosis. Rapid tests such as Bioline™ DENGUE DUO have gained traction, but validation in specific populations is essential. This study aimed to evaluate the performance of the Bioline™ test, alongside assessing the socio-epidemiological profile of symptomatic patients in a Brasília Military Hospital. The serum of 404 symptomatic patients was analyzed by the Bioline™ DENGUE DUO test, followed by Dengue virus detection and discrimination of the four serotypes by RT-qPCR. Accuracy was assessed using parameters including sensitivity (S), specificity (E), positive and negative predictive values (PPV and NPV), and positive (RV +) and negative (RV-) likelihood ratios. The NS1 component exhibited a sensitivity of 70.37%, a specificity of 97.30%, and an overall efficiency of 90.10% when compared to RT-qPCR as the gold standard. The IgM component demonstrated a sensitivity of 26.85%, a specificity of 89.53%, and an overall efficiency of 72.77% when compared to RT-qPCR as the gold standard. The IgG component demonstrated a sensitivity of 23.15%, a specificity of 68.92%, and an overall efficiency of 56.68% when compared to RT-qPCR as the gold standard. Several rapid tests are commercially available. However, considering variations across regions and demographic groups, it is important to question their accuracy in specific populations. Rapid tests are important screening tools, but they can have limitations for the certainty of diagnosis. Bioline™ DENGUE DUO displayed good specificity, but sensitivity was slightly below optimal levels. While helpful for confirming dengue, improvements are needed to effectively rule out the disease.
- 6 May 2024
- Published by Springer Nature in Brazilian Journal of Microbiology
- Vol. 55 (2) , 1801-1809
Diagnostic performance of the bioline dengue duo rapid test on symptomatic patients assisted at Armed Forces Hospital (Hfa) in Brasília, Brazil
Dengue necessitates accurate diagnosis. Rapid tests such as Bioline™ DENGUE DUO have gained traction, but validation in specific populations is essential. This study aimed to evaluate the performance of the Bioline™ test, alongside assessing the socio-epidemiological profile of symptomatic patients in a Brasília Military Hospital. The serum of 404 symptomatic patients was analyzed by the Bioline™ DENGUE DUO test, followed by Dengue virus detection and discrimination of the four serotypes by RT-qPCR. Accuracy was assessed using parameters including sensitivity (S), specificity (E), positive and negative predictive values (PPV and NPV), and positive (RV +) and negative (RV-) likelihood ratios. The NS1 component exhibited a sensitivity of 70.37%, a specificity of 97.30%, and an overall efficiency of 90.10% when compared to RT-qPCR as the gold standard. The IgM component demonstrated a sensitivity of 26.85%, a specificity of 89.53%, and an overall efficiency of 72.77% when compared to RT-qPCR as the gold standard. The IgG component demonstrated a sensitivity of 23.15%, a specificity of 68.92%, and an overall efficiency of 56.68% when compared to RT-qPCR as the gold standard. Several rapid tests are commercially available. However, considering variations across regions and demographic groups, it is important to question their accuracy in specific populations. Rapid tests are important screening tools, but they can have limitations for the certainty of diagnosis. Bioline™ DENGUE DUO displayed good specificity, but sensitivity was slightly below optimal levels. While helpful for confirming dengue, improvements are needed to effectively rule out the disease.
- Open Access
- 1 January 2024
- Vol. 57, e007112024
Molecular detection of multiple arboviruses in the city of Goiania-Goias-Brazil
Background: Healthcare systems are currently ill-equipped to diagnose arboviruses rapidly and efficiently or to differentiate between various viruses. Methods: Utilizing molecular techniques, this study examined arbovirus infections in 459 patients from a public health unit in Goi & acirc;nia-Goi & aacute;s, Brazil, a region where arbovirus infection poses a significant public health challenge. Results: Nearly 60% of the analyzed samples tested positive for at least one arbovirus, and over 10% of the patients were co-infected with more than one virus. Conclusions: Fast and accurate diagnostic tools are essential for informing public health policy and enhancing epidemiological surveillance.
- 1 January 2024
- Vol. 57, e007112024
Open AccessMolecular detection of multiple arboviruses in the city of Goiania-Goias-Brazil
Background: Healthcare systems are currently ill-equipped to diagnose arboviruses rapidly and efficiently or to differentiate between various viruses. Methods: Utilizing molecular techniques, this study examined arbovirus infections in 459 patients from a public health unit in Goi & acirc;nia-Goi & aacute;s, Brazil, a region where arbovirus infection poses a significant public health challenge. Results: Nearly 60% of the analyzed samples tested positive for at least one arbovirus, and over 10% of the patients were co-infected with more than one virus. Conclusions: Fast and accurate diagnostic tools are essential for informing public health policy and enhancing epidemiological surveillance.