GPGeiland Porrovecchio

Geiland Porrovecchio

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Geiland Porrovecchio has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Realization of a primary irradiance scale for solar irradiance measurements based on a predictable quantum efficient detector and a quasi-monochromatic portable tunable source

    by Geiland Porrovecchio, Julian Gröbner, Marek Smid

    Long-term solar ultraviolet (UV) monitoring for climate modeling and ozone trend assessment demands exceptionally low measurement uncertainties. Traditional lamp-based radiometric calibrations using standard FEL lamps suffer from high intrinsic uncertainties in the UV region and are highly susceptible to drift over time. To address this gap, this work presents a primary, detector-based irradiance scale for solar UV measurements covering the 350 nm to 550 nm spectral range of the QASUME reference solar spectroradiometer. The proposed scale relies on a predictable quantum efficient detector (PQED) built with self-induced silicon photodiodes in a trap configuration. While PQEDs naturally exhibit near-unitary internal quantum efficiency between 450 nm and 850 nm, their extension into the UV requires accounting for impact ionization via an enhanced Quantum Yield effect. By implementing a validated quantum Yield model experimentally verified against the cryogenic radiometer primary standard at the Czech Metrology Institute (CMI), the scale achieves an estimated primary irradiance standard uncertainty of 0.28% in the near-UV range (350–425 nm) and 0.20% at wavelengths longer than 425 nm, which is a factor of 2 improvement compared to the current source-based scale. The realization of the detector-based scale is based on a transportable tunable light source (TuPS) alongside an automated comparison facility comprising a PQED as the primary irradiance reference, establishing an in-situ, highly accurate traceability chain for the QASUME reference spectroradiometer.

  • Open Access

    Quantum yield of silicon in the spectral range from ultraviolet to visible

    by Toomas Kübarsepp, Meelis-Mait Sildoja, Jaanus Vahi, Aarre Kilpeläinen, Farshid Manoocheri, Peter Meindl, Tobias Pohl, Lutz Werner, Marek Šmid, Geiland Porrovecchio, et al.

    The essential steps for simulating the quantum yield of silicon have been thoroughly studied in the wavelength range from ultraviolet to visible. We have separately estimated excess quantum yield contributions arising from primary carriers created after photon absorption using the Quantum Espresso software. This is acheived by calculating the distribution functions of charge carriers over the available energy range and the probabilities of charge carriers generating secondary carriers. The resulting quantum yield values are compared to those obtained using high-accuracy measurement data from different types of silicon-based predictable quantum efficient detectors (PQEDs), indicating better than ±2.5% relative agreement within the spectral interval 200 nm—480 nm.


  • Open Access

    Survey of bidirectional transmittance distribution function measurement facilities by multilateral scale comparisons

    by Jinglin Fu, Alejandro Ferrero, Tatjana Quast, Michael Esslinger, Pablo Santafé-Gabarda, Néstor Tejedor, Joaquín Campos, Lou Gevaux, Gaël Obein, Robin Aschan, et al.

    In recent years, a growing demand for the capability of performing accurate measurements of the bidirectional transmittance distribution function (BTDF) has been observed in industry, research and development, and aerospace applications. However, there exists no calibration and measurement capabilities-entry for BTDF in the database of the Bureau International des Poids et Mesures and to date no BTDF comparison has been conducted between different national metrology institutes (NMIs) or designated institutes (DIs). As a first step to a possible future key comparison and to test the existing capabilities of determining this measurand, two interlaboratory comparisons were performed. In comparison one, five samples of three different types of optical transmissive diffusers were measured by five NMIs and one DI. By specific sample choice, the focus for this study lay more on orientation-dependent scatter properties. In comparison two, where one NMI, one DI, one university, and three industrial partners investigated their measurement capabilities, the dependence on the orientation was not assessed, but two additional samples of the same material and different thickness were measured. Results of the two comparisons are presented, giving a good overview of existing experimental solutions, and showing specific sample-related problems to be solved for improved future BTDF measurements.


  • Development of a switched integrator amplifier for high-accuracy optical measurements

    by John Mountford, Geiland Porrovecchio, Marek Smid, Radislav Smid

    In the field of low flux optical measurements, the development and use of large area silicon detectors is becoming more frequent. The current/voltage conversion of their photocurrent presents a set of problems for traditional transimpedance amplifiers. The switched integration principle overcomes these limitations. We describe the development of a fully characterized current-voltage amplifier using the switched integrator technique. Two distinct systems have been developed in parallel at the United Kingdom’s National Physical Laboratory (NPL) and Czech Metrology Institute (CMI) laboratories. We present the circuit theory and best practice in the design and construction of switched integrators. In conclusion the results achieved and future developments are discussed.


  • Radiation-induced effects on the XAA1.2 ASIC chip for space application

    by Ettore Del Monte, Luigi Pacciani, Geiland Porrovecchio, Paolo Soffitta, Enrico Costa, Giuseppe Di Persio, Marco Feroci, Marcello Mastropietro, Ennio Morelli, Massimo Rapisarda, et al.