Seonghyeon Won
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Seonghyeon Won has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Daehie Hong
Department of Mechanical Engineering, Korea University, Seoul, South Korea
6 shared publications - Chanwoo Kim
Korea University, Seoul, South Korea
4 shared publications - Junho Hong
Korea University, Seoul, South Korea
3 shared publications Chanwoo Kim
Department of Mechanical Engineering Korea University Seoul Republic of Korea
2 shared publications- Yeonho Ko
Department of Mechanical Engineering, Korea University, Seoul, South Korea
2 shared publications - Bora Keum
Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, Seoul, Korea
1 shared publication
Latest Publications
- 4 August 2026
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 22 (4) , e70218
Design and Evaluation of a Teleoperated Robotic System for ERCP Cannulation
Background: Endoscopic retrograde cholangiopancreatography (ERCP) cannulation requires precise manipulation under fluoroscopic guidance. This study proposes a teleoperated robotic system for ERCP cannulation and evaluates its simulator‐based performance. Methods: A teleoperated robotic system incorporating a Chebyshev‐based mechanism and a ring‐type master interface was developed. Manipulation performance was assessed using Fitts' law‐based insertion experiments, catheter‐tip trajectory analysis, and a simulator‐based cannulation task. Results: Robotic manipulation showed a Fitts' law relationship comparable to conventional manual operation. Trajectory analysis showed higher path efficiency and lower jerk in the robotic condition, indicating improved trajectory‐related motion quality. In the simulator‐based cannulation task, the robotic condition showed slightly longer initial task completion times, whereas both robotic and conventional conditions showed comparable changes in task completion time across repeated trials. Conclusions: This study demonstrates the feasibility of a teleoperated robotic system for simulator‐based ERCP cannulation tasks. Further validation with expert endoscopists and more realistic ERCP environments is required.
- 4 August 2026
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 22 (4) , e70218
Design and Evaluation of a Teleoperated Robotic System for ERCP Cannulation
Background: Endoscopic retrograde cholangiopancreatography (ERCP) cannulation requires precise manipulation under fluoroscopic guidance. This study proposes a teleoperated robotic system for ERCP cannulation and evaluates its simulator‐based performance. Methods: A teleoperated robotic system incorporating a Chebyshev‐based mechanism and a ring‐type master interface was developed. Manipulation performance was assessed using Fitts' law‐based insertion experiments, catheter‐tip trajectory analysis, and a simulator‐based cannulation task. Results: Robotic manipulation showed a Fitts' law relationship comparable to conventional manual operation. Trajectory analysis showed higher path efficiency and lower jerk in the robotic condition, indicating improved trajectory‐related motion quality. In the simulator‐based cannulation task, the robotic condition showed slightly longer initial task completion times, whereas both robotic and conventional conditions showed comparable changes in task completion time across repeated trials. Conclusions: This study demonstrates the feasibility of a teleoperated robotic system for simulator‐based ERCP cannulation tasks. Further validation with expert endoscopists and more realistic ERCP environments is required.
- Open Access
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 26381-26390
Shape-Locking Mechanism Using Double Pawl–Ratchet System for Endoscopic Surgery
Flexible endoscopic instruments must achieve a balance between high maneuverability and sufficient stability to withstand external forces. However, conventional variable stiffness methods, such as thermal actuation, and particle jamming are limited by response time, achievable stiffness, and compactness of integration. To address these challenges in surgical environments, we introduce a double pawl–ratchet mechanism for shape locking. Unlike single-direction ratchets, the double pawl configuration restricts motion in both bending directions, enabling stable configurations once engaged. The proposed design accommodates passage through a 20 mm natural orifice and provides an angulation range comparable to that of a conventional endoscope. With an outer diameter of 19.8 mm and a bending capacity of ±90° per section, the system shows a stiffness of approximately 0.88 N/mm. These results validate that the double pawl–ratchet mechanism can maintain structural stability under lateral loading while preserving compactness. Overall, the findings confirm that the mechanism provides both locking capability and dexterity consistent with conventional endoscopic standards.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 26381-26390
Open AccessShape-Locking Mechanism Using Double Pawl–Ratchet System for Endoscopic Surgery
Flexible endoscopic instruments must achieve a balance between high maneuverability and sufficient stability to withstand external forces. However, conventional variable stiffness methods, such as thermal actuation, and particle jamming are limited by response time, achievable stiffness, and compactness of integration. To address these challenges in surgical environments, we introduce a double pawl–ratchet mechanism for shape locking. Unlike single-direction ratchets, the double pawl configuration restricts motion in both bending directions, enabling stable configurations once engaged. The proposed design accommodates passage through a 20 mm natural orifice and provides an angulation range comparable to that of a conventional endoscope. With an outer diameter of 19.8 mm and a bending capacity of ±90° per section, the system shows a stiffness of approximately 0.88 N/mm. These results validate that the double pawl–ratchet mechanism can maintain structural stability under lateral loading while preserving compactness. Overall, the findings confirm that the mechanism provides both locking capability and dexterity consistent with conventional endoscopic standards.
- Open Access
- 25 July 2025
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 21 (4) , e70095
Novel Design of a Surgical Tool Insertion Robot Using a Chebyshev Lambda Mechanism
Background: Endoscopic Retrograde Cholangiopancreatography (ERCP) and Percutaneous Coronary Intervention (PCI) are minimally invasive procedures that treat diseases with minimal scarring and rapid recovery. However, catheterisation under fluoroscopy exposes medical staff to radiation, and navigating flexible guidewires through complex anatomical pathways requires precise control.Methods: To address these challenges, we propose a novel insertion robot based on a Chebyshev lambda mechanism that makes a linear grasp path and an arc‐shaped quick return path using a single motor. An integrated roll module enables continuous insertion and rotation, yielding a robot with two degrees of freedom.Results: Experiments show robots can make sufficient insertion force for real procedures, with robot's maximum mean translational and rotational errors of 0.11 mm and 1.47°, respectively. Phantom model tests show its applicability to human anatomy.Conclusions: The proposed robotic system demonstrated sufficient precision and force for real surgical applications, indicating its potential for clinical use in minimally invasive procedures.
- 25 July 2025
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 21 (4) , e70095
Open AccessNovel Design of a Surgical Tool Insertion Robot Using a Chebyshev Lambda Mechanism
Background: Endoscopic Retrograde Cholangiopancreatography (ERCP) and Percutaneous Coronary Intervention (PCI) are minimally invasive procedures that treat diseases with minimal scarring and rapid recovery. However, catheterisation under fluoroscopy exposes medical staff to radiation, and navigating flexible guidewires through complex anatomical pathways requires precise control.Methods: To address these challenges, we propose a novel insertion robot based on a Chebyshev lambda mechanism that makes a linear grasp path and an arc‐shaped quick return path using a single motor. An integrated roll module enables continuous insertion and rotation, yielding a robot with two degrees of freedom.Results: Experiments show robots can make sufficient insertion force for real procedures, with robot's maximum mean translational and rotational errors of 0.11 mm and 1.47°, respectively. Phantom model tests show its applicability to human anatomy.Conclusions: The proposed robotic system demonstrated sufficient precision and force for real surgical applications, indicating its potential for clinical use in minimally invasive procedures.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (7) , 7015-7022
Adaptive Hybrid Control for Backlash-Like Hysteresis and Marker-Based Pose Estimation in Endoscopic Robots
Nonlinear backlash-like hysteresis in tendon-sheath mechanism based endoscopic surgical robots introduces significant motion errors, limiting precision in surgical tasks. Existing methods struggle to compensate for these errors in real time, particularly without relying on distal-end sensors. To address this challenge, we introduce novel hybrid control strategy integrating adaptive feedforward and feedback control, enabling real-time deadband compensation and disturbance rejection. Unlike conventional approaches, our method does not require distal sensors and incorporates a vision-based tracking technique inspired by medical dye techniques. Two blue markers, attached to the robot arm, are tracked in HSV color space, allowing accurate angle estimation via polynomial regression, eliminating the need for high-clarity imaging as required in conventional laparoscopic tracking methods. Not only does our method guarantee ultimate boundedness from a control-theoretic perspective, but experimental validation under simulated surgical conditions also demonstrates a 98.6% reduction in RMSE, achieving 0.025 mm tracking error, compared to no control (1.815 mm), P-control (0.374 mm), and adaptive feedforward control (0.152 mm). The system adapts rapidly to abrupt tension changes, ensuring stable and precise control. By improving control accuracy and eliminating the need for distal sensors, our method enhances the reliability of endoscopic robotic systems, contributing to safer and more precise minimally invasive surgical procedures.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (7) , 7015-7022
Adaptive Hybrid Control for Backlash-Like Hysteresis and Marker-Based Pose Estimation in Endoscopic Robots
Nonlinear backlash-like hysteresis in tendon-sheath mechanism based endoscopic surgical robots introduces significant motion errors, limiting precision in surgical tasks. Existing methods struggle to compensate for these errors in real time, particularly without relying on distal-end sensors. To address this challenge, we introduce novel hybrid control strategy integrating adaptive feedforward and feedback control, enabling real-time deadband compensation and disturbance rejection. Unlike conventional approaches, our method does not require distal sensors and incorporates a vision-based tracking technique inspired by medical dye techniques. Two blue markers, attached to the robot arm, are tracked in HSV color space, allowing accurate angle estimation via polynomial regression, eliminating the need for high-clarity imaging as required in conventional laparoscopic tracking methods. Not only does our method guarantee ultimate boundedness from a control-theoretic perspective, but experimental validation under simulated surgical conditions also demonstrates a 98.6% reduction in RMSE, achieving 0.025 mm tracking error, compared to no control (1.815 mm), P-control (0.374 mm), and adaptive feedforward control (0.152 mm). The system adapts rapidly to abrupt tension changes, ensuring stable and precise control. By improving control accuracy and eliminating the need for distal sensors, our method enhances the reliability of endoscopic robotic systems, contributing to safer and more precise minimally invasive surgical procedures.
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (6) , 5201-5208
On-line Shape Estimation for Hysteresis Compensation in Tendon-Sheath Mechanisms Using Endoscopic Camera
The tendon-sheath mechanism (TSM) has significantly advanced both robotic systems and minimally invasive surgery (MIS) by enabling flexible and precise movement through narrow and tortuous paths. However, the inherent flexibility of TSM introduces nonlinear behaviors which depend on its geometrical shape and applied forces, making accurate control challenging. Furthermore, the shape dependency becomes critical in endoscopic robots, where the geometrical shape varies and is not directly visible, limiting the applicability of existing distal sensorless compensation methods. To address the geometry identification problem of TSM, this paper proposes an approach that utilizes real-time visual input from an endoscopic camera for on-line calibration of the TSM's physical model. By introducing the concept of the ‘Equivalent Circle,’ complex shapes of TSMs are simplified, enabling the estimation of their equivalent geometry without direct observation or measurement. Simulation results validate the equivalent circle model, demonstrating minimal deadband percentage errors despite larger discrepancies in equivalent radii across varied configurations. On-line calibration experiments achieved a percent error of 1.38% (±2.92%) for accumulated curve angles and 2.32% (±3.08%) for equivalent radii, demonstrating the method's reliability in shape estimation across varying conditions. In prediction and feedforward experiments, leveraging the equivalent circle to compensate for deadband in arbitrarily shaped TSMs resulted in a maximum trajectory error of 0.25 mm and an RMSE of 0.09 mm. This approach advances distal sensorless control, improving the operational accuracy and feasibility of endoscopic surgical robots under varying geometrical and force conditions.
- 2 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (6) , 5201-5208
On-line Shape Estimation for Hysteresis Compensation in Tendon-Sheath Mechanisms Using Endoscopic Camera
The tendon-sheath mechanism (TSM) has significantly advanced both robotic systems and minimally invasive surgery (MIS) by enabling flexible and precise movement through narrow and tortuous paths. However, the inherent flexibility of TSM introduces nonlinear behaviors which depend on its geometrical shape and applied forces, making accurate control challenging. Furthermore, the shape dependency becomes critical in endoscopic robots, where the geometrical shape varies and is not directly visible, limiting the applicability of existing distal sensorless compensation methods. To address the geometry identification problem of TSM, this paper proposes an approach that utilizes real-time visual input from an endoscopic camera for on-line calibration of the TSM's physical model. By introducing the concept of the ‘Equivalent Circle,’ complex shapes of TSMs are simplified, enabling the estimation of their equivalent geometry without direct observation or measurement. Simulation results validate the equivalent circle model, demonstrating minimal deadband percentage errors despite larger discrepancies in equivalent radii across varied configurations. On-line calibration experiments achieved a percent error of 1.38% (±2.92%) for accumulated curve angles and 2.32% (±3.08%) for equivalent radii, demonstrating the method's reliability in shape estimation across varying conditions. In prediction and feedforward experiments, leveraging the equivalent circle to compensate for deadband in arbitrarily shaped TSMs resulted in a maximum trajectory error of 0.25 mm and an RMSE of 0.09 mm. This approach advances distal sensorless control, improving the operational accuracy and feasibility of endoscopic surgical robots under varying geometrical and force conditions.
- Open Access
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 153952-153964
Wearable Extra Robotic Limb System With a Constant-Orientation Mechanism for the Handling of Construction Material
A wearable extra robotic limb (XRL) system is a wearable robotic system that directly assists in handling materials and tools, differentiating it from exoskeleton robots, which tend to directly support the joints. XRL systems thus hold promise for the prevention of work-related musculoskeletal disorders (WMSDs) among construction workers. However, there is a lack of specific designs for construction tasks. Therefore, this paper analyzes a workpiece handling task to derive operating mechanisms and design parameters for an XRL system that can provide sufficient assistance. The proposed design aims to provide the worker with constant orientation for intuitive tasks, thus eliminating unnecessary elements and reducing the burden on the wearer. A finite state machine algorithm is also employed to convey the worker’s intent when handling a workpiece, enabling intuitive collaboration. To validate the proposed design, two experiments are conducted, with the results demonstrating that the use of the robotic system effectively assists the wearer with tasks and reduces musculoskeletal strain, thus reducing the risk of WMSDs.
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 153952-153964
Open AccessWearable Extra Robotic Limb System With a Constant-Orientation Mechanism for the Handling of Construction Material
A wearable extra robotic limb (XRL) system is a wearable robotic system that directly assists in handling materials and tools, differentiating it from exoskeleton robots, which tend to directly support the joints. XRL systems thus hold promise for the prevention of work-related musculoskeletal disorders (WMSDs) among construction workers. However, there is a lack of specific designs for construction tasks. Therefore, this paper analyzes a workpiece handling task to derive operating mechanisms and design parameters for an XRL system that can provide sufficient assistance. The proposed design aims to provide the worker with constant orientation for intuitive tasks, thus eliminating unnecessary elements and reducing the burden on the wearer. A finite state machine algorithm is also employed to convey the worker’s intent when handling a workpiece, enabling intuitive collaboration. To validate the proposed design, two experiments are conducted, with the results demonstrating that the use of the robotic system effectively assists the wearer with tasks and reduces musculoskeletal strain, thus reducing the risk of WMSDs.
- Open Access
- 7 May 2024
- Published by The Editorial Office of Gut and Liver in Gut and Liver
- Vol. 18 (4) , 677-685
A Novel Retractable Robotic Device for Colorectal Endoscopic Submucosal Dissection
Sang Hyun Kim, Chanwoo Kim, Bora Keum, Junghyun Im, Seonghyeon Won, Byung Gon Kim, Kyungnam Kim, Taebin Kwon, Daehie Hong, Han Jo Jeon, Hyuk Soon Choi, Eun Sun Kim, Yoon Tae Jeen, Hoon Jai Chun, Joo Ha Hwang. Gut and Liver 2024;18:677-85. https://doi.org/10.5009/gnl230280
- 7 May 2024
- Published by The Editorial Office of Gut and Liver in Gut and Liver
- Vol. 18 (4) , 677-685
Open AccessA Novel Retractable Robotic Device for Colorectal Endoscopic Submucosal Dissection
Sang Hyun Kim, Chanwoo Kim, Bora Keum, Junghyun Im, Seonghyeon Won, Byung Gon Kim, Kyungnam Kim, Taebin Kwon, Daehie Hong, Han Jo Jeon, Hyuk Soon Choi, Eun Sun Kim, Yoon Tae Jeen, Hoon Jai Chun, Joo Ha Hwang. Gut and Liver 2024;18:677-85. https://doi.org/10.5009/gnl230280