Volodymyr Kuts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Volodymyr Kuts has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Svitlana Kovtun
General Energy Institute of National Academy of Sciences of Ukraine, 172, Antonovycha St., Kyiv, 03150, Ukraine
3 shared publications - Yurii Kuts
General Energy Institute of NAS of Ukraine
3 shared publications - Mykhailo Fryz
General Energy Institute of NAS of Ukraine
2 shared publications - Volodymyr Malko
General Energy Institute of NAS of Ukraine
2 shared publications - Artem Karaban
General Energy Institute of NAS of Ukraine,172 Antonovycha St., Kyiv, 03150, Ukraine
1 shared publication - Artur Zaporozhets
General Energy Institute of National Academy of Sciences of Ukraine, Kyiv, Ukraine; International Institute for Applied Systems Analysis, Laxenburg, Austria, Ukraine
1 shared publication
Latest Publications
- Open Access
- 30 May 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2026 (2) , 52-63
RANDOM ANGLE GENERATOR IN THE ATMOSPHERIC MONITORING SYSTEM OF ENERGY FACILITIES
The complication of maintaining the power balance in the energy system under martial law conditions, ensuring the normal operating modes of power facility equipment, and maintaining the required quality of fossil energy resources used, among other factors, leads to an increase in harmful emissions into the atmosphere. Therefore, the development and improvement of environmental monitoring tools for energy facilities has become particularly relevant. In environmental monitoring systems, primary measurement information is generated by a system of sensors located around sources of pollutant emissions. One of the important tasks in the analysis of experimental data is the estimation of the distribution of pollutant concentrations in the vicinity of energy facilities using polar coordinates. To address this problem, modules for statistical analysis of circular data are included in the algorithmic and software support of monitoring systems. The task of verifying such modules requires the development of random angle generators capable of producing test samples of random angles with complex probability distributions. The article considers the methodological basis for solving problems of computer experiments with random angles, substantiates the use of multimodal probability distributions in problems of circular data analysis for atmospheric monitoring, proposes a random angle generator, and performs its verification using the example of generating a sample with a bimodal distribution. To evaluate the adequacy of the theoretical and empirical probability distributions of the random angle, the Kolmogorov criterion is used. The developed generator makes it possible to obtain samples of random angles with distributions defined analytically, by a table or graph (histogram), and can be used for testing algorithmic and software support in systems for statistical analysis of circular data. Keywords: random angle generator, computer experiment, trigonometric moments method, bimodal distributions of random angles.
- 30 May 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2026 (2) , 52-63
Open AccessRANDOM ANGLE GENERATOR IN THE ATMOSPHERIC MONITORING SYSTEM OF ENERGY FACILITIES
The complication of maintaining the power balance in the energy system under martial law conditions, ensuring the normal operating modes of power facility equipment, and maintaining the required quality of fossil energy resources used, among other factors, leads to an increase in harmful emissions into the atmosphere. Therefore, the development and improvement of environmental monitoring tools for energy facilities has become particularly relevant. In environmental monitoring systems, primary measurement information is generated by a system of sensors located around sources of pollutant emissions. One of the important tasks in the analysis of experimental data is the estimation of the distribution of pollutant concentrations in the vicinity of energy facilities using polar coordinates. To address this problem, modules for statistical analysis of circular data are included in the algorithmic and software support of monitoring systems. The task of verifying such modules requires the development of random angle generators capable of producing test samples of random angles with complex probability distributions. The article considers the methodological basis for solving problems of computer experiments with random angles, substantiates the use of multimodal probability distributions in problems of circular data analysis for atmospheric monitoring, proposes a random angle generator, and performs its verification using the example of generating a sample with a bimodal distribution. To evaluate the adequacy of the theoretical and empirical probability distributions of the random angle, the Kolmogorov criterion is used. The developed generator makes it possible to obtain samples of random angles with distributions defined analytically, by a table or graph (histogram), and can be used for testing algorithmic and software support in systems for statistical analysis of circular data. Keywords: random angle generator, computer experiment, trigonometric moments method, bimodal distributions of random angles.
- 3 July 2025
- Published by Springer Nature
- p. 25-56
Methodology for Assessment the Power Quality Characteristics of the Supply Voltage of General-Purpose Power Grids
- 3 July 2025
- Published by Springer Nature
- p. 25-56
Methodology for Assessment the Power Quality Characteristics of the Supply Voltage of General-Purpose Power Grids
- Open Access
- 5 May 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2024 (2) , 71-83
Application of hilbert transform for power quality indicators monitoring in general purpose grids
During the operation of power grids, abnormal modes occur that lead to a decrease or increase in the grid voltage beyond permissible values, the appearance of high-frequency noise components and grid signal fading’s, which fading’s the power quality and can lead to the failure of electrical equipment. This requires constant monitoring of power quality indicators. The methods of measuring power quality indicators have been examined and analyzed in the article, their advantages and limitations have been considered, and the inefficiency of using the Fourier transform for estimating of power quality indicators in time domain has been justified. The application of Hilbert transform has been suggested for monitoring the indicators of power quality in general-purpose grids, which include measuring the duration and magnitude of voltage dips, the duration of voltage fading, localization and determination of the duration of high-frequency noise interference in the power grid, determination of phase shift during voltage dip. A simulation of the process of determining the indicators of power quality in time domain and the time intervals during which these indicators exceed the established limits has been performed, which confirmed the effectiveness of using the Hilbert transform in the systems of their monitoring. Keywords: general purpose power grid, power quality indicators, Hilbert transform.
- 5 May 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in System Research in Energy
- Vol. 2024 (2) , 71-83
Open AccessApplication of hilbert transform for power quality indicators monitoring in general purpose grids
During the operation of power grids, abnormal modes occur that lead to a decrease or increase in the grid voltage beyond permissible values, the appearance of high-frequency noise components and grid signal fading’s, which fading’s the power quality and can lead to the failure of electrical equipment. This requires constant monitoring of power quality indicators. The methods of measuring power quality indicators have been examined and analyzed in the article, their advantages and limitations have been considered, and the inefficiency of using the Fourier transform for estimating of power quality indicators in time domain has been justified. The application of Hilbert transform has been suggested for monitoring the indicators of power quality in general-purpose grids, which include measuring the duration and magnitude of voltage dips, the duration of voltage fading, localization and determination of the duration of high-frequency noise interference in the power grid, determination of phase shift during voltage dip. A simulation of the process of determining the indicators of power quality in time domain and the time intervals during which these indicators exceed the established limits has been performed, which confirmed the effectiveness of using the Hilbert transform in the systems of their monitoring. Keywords: general purpose power grid, power quality indicators, Hilbert transform.