JEJessica Eberle

Jessica Eberle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jessica Eberle has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Finite sample size errors in the context of multiple error sources in quantitative medical imaging: An evaluation for breast magnetic resonance diffusion-weighted imaging

    by Jessica V. Eberle, Sebastian Bickelhaupt, Lorenz A. Kapsner, Sabine Ohlmeyer, Evelyn Wenkel, Michael Uder, Dominika Skwierawska, Katharina Tkotz, Dominique Hadler, Tristan A. Kuder, et al.

    Background: Selecting appropriate sample sizes in magnetic resonance imaging studies is a complex process that requires to balance statistical rigor with the practical challenges of measuring a large patient population. In this Institutional Review Board approved study, we evaluate the dominant error types (“finite N” errors versus precision errors) for apparent diffusion coefficient (ADC)-based lesion characterization in diffusion-weighted magnetic resonance imaging (DWI) of the female breast in a local dataset and compare our results with current literature. Methods: First, in a literature review including 24 published breast DWI studies, the standard error of the area under the receiver operating characteristic curve as a measure of sample size-related errors (finite N errors) was estimated for the reported ADC values and compared to the values, derived from expert readings of a university hospital’s cohort of 171 patients with suspicious breast lesions. Second, precision errors were assessed based on published analyses of the coefficient of variation of ADC values, measured in breast DWI exams. Results: Finite N errors were dominant in the in-house study and most of the 24 reviewed studies. The median sample size at which finite N errors and precision errors were equal was determined to be n = 932. Discussion: This analysis of dominant error types shows that the required sample sizes for the considered use case are not unreasonably large and that reducing sample sizes may not be justified based on the merits of the conducted analysis. Nonetheless, incorporating dominant error type assessments into future studies may provide valuable insights for optimizing study design and improving methodological rigor.

  • Open Access

    Risk-adjusted training and evaluation for breast cancer detection

    by Dimitrios Bounias, Michael Baumgartner, Peter Neher, Balint Kovacs, Ralf Floca, Lorenz A. Kapsner, Jessica Eberle, Dominique Hadler, Frederik Laun, Sabine Ohlmeyer, et al.


  • Open Access

    AI-Based screening for thoracic aortic aneurysms in routine breast MRI

    by Dimitrios Bounias, Tobit Führes, Luise Brock, Johanna Graber, Lorenz A. Kapsner, Andrzej Liebert, Hannes Schreiter, Jessica Eberle, Dominique Hadler, Dominika Skwierawska, et al.

    Prognosis for thoracic aortic aneurysms is significantly worse for women than men, with a higher mortality rate observed among female patients. The increasing use of magnetic resonance breast imaging (MRI) offers a unique opportunity for simultaneous detection of both breast cancer and thoracic aortic aneurysms. We retrospectively validate a fully-automated artificial neural network (ANN) pipeline on 5057 breast MRI examinations from public (Duke University Hospital/EA1141 trial) and in-house (Erlangen University Hospital) data. The ANN, benchmarked against 3D-ground-truth segmentations, clinical reports, and a multireader panel, demonstrates high technical robustness (dice/clDice 0.88-0.91/0.97-0.99) across different vendors and field strengths. The ANN improves aneurysm detection rates by 3.5-fold compared with routine clinical readings, highlighting its potential to improve early diagnosis and patient outcomes. Notably, a higher odds ratio (OR = 2.29, CI: [0.55,9.61]) for thoracic aortic aneurysms is observed in women with breast cancer or breast cancer history, suggesting potential further benefits from integrated simultaneous assessment for cancer and aortic aneurysms.


  • Open Access

    Feasibility to virtually generate T2 fat-saturated breast MRI by convolutional neural networks

    by Andrzej Liebert, Dominique Hadler, Chris Ehring, Hannes Schreiter, Luise Brock, Lorenz A. Kapsner, Jessica Eberle, Ramona Erber, Julius Emons, Frederik B. Laun, et al.

    Background Breast magnetic resonance imaging (MRI) protocols often include T2-weighted fat-saturated (T2w-FS) sequences, which are vital for tissue characterization but significantly increase scan time. Purpose This study aims to evaluate whether a 2D-U-Net neural network can generate virtual T2w-FS images from routine multiparametric breast MRI sequences. Materials and Methods This IRB approved, retrospective study included n=914 breast MRI examinations performed between January 2017 and June 2020. The dataset was divided into training (n=665), validation (n=74), and test sets (n=175). The U-Net was trained on T1-weighted (T1w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) sequences to generate virtual T2w-FS images (VirtuT2). Quantitative metrics and a qualitative multi-reader assessment by two radiologists were used to evaluate the VirtuT2 images. Results VirtuT2 images demonstrated high structural similarity (SSIM=0.87) and peak signal-to-noise ratio (PSNR=24.90) compared to original T2w-FS images. High level of the frequency error norm (HFNE=0.87) indicates strong blurring presence in the VirtuT2 images, which was also confirmed in qualitative reading. Radiologists correctly identified VirtuT2 images with 92.3% and 94.2% accuracy, respectively. No significant difference in diagnostic image quality (DIQ) was noted for one reader (p=0.21), while the other reported significantly lower DIQ for VirtuT2 (p<=0.001). Moderate inter-reader agreement was observed for edema detection on T2w-FS images (ƙ=0.43), decreasing to fair on VirtuT2 images (ƙ=0.36). Conclusion The 2D-U-Net can technically generate virtual T2w-FS images with high similarity to real T2w-FS images, though blurring remains a limitation. Further investigation of other architectures and using larger datasets are needed to improve clinical applicability. Summary Statement Virtual T2-weighted fat-saturated images can be generated from routine breast MRI sequences using convolutional neural networks, showing high structural similarity but with notable blurring, necessitating further refinement for clinical use. Key Results Images with T2w-FS characteristics can be virtually generated from T1w and DWI images using deep learning Image blurring occurring in the VirtuT2 image limit clinical use for the current moment Further investigation of different architectures and with larger datasets are necessary in the future to improve the VirtuT2 performance.


  • Open Access

    Impact of Non-Contrast Enhanced Imaging Input Sequences on the Generation of Virtual Contrast-Enhanced Breast MRI Scans using Neural Networks

    by Andrzej Liebert, Hannes Schreiter, Lorenz A Kapsner, Jessica Eberle, Chris Ehring, Dominique Hadler, Luise Brock, Ramona Erber, Julius Emons, Frederik B. Laun, et al.

    Background: Virtual contrast-enhanced (vCE) imaging techniques are an emerging topic of research in breast MRI. Purpose: To investigate how different combinations of T1-weighted (T1w), T2-weighted (T2w), and diffusion-weighted imaging (DWI) impact the performance of vCE breast MRI. Materials and Methods: The IRB-approved, retrospective study included 1064 multiparametric breast MRI scans (age:52±12 years) obtained from 2017-2020 (single site, two 3T MRI). Eleven independent neural networks were trained to derive vCE images from varying input combinations of T1w, T2w, and multi-b-value DWI sequences (b-value=50–1500s/mm 2 ). Three readers evaluated the vCE images with regards to qualitative scores of diagnostic image quality, image sharpness, satisfaction with contrast/signal-to-noise-ratio, and lesion/non-mass enhancement conspicuity. Quantitative metrics (SSIM, PSNR, NRMSE, and median symmetrical accuracy) were analyzed and statistically compared between the input combinations for the full breast volume and both enhancing and non-enhancing target findings. Results: The independent test set consisted of 187 cases. The quantitative metrics significantly improved in target findings when multi-b-value DWI sequences were included during vCE training (p<.05). Non-significant effects (p>.05) were observed for the quantitative metrics on the full breast volume when comparing input combinations including T1w. Using T1w and DWI acquisitions during vCE training is necessary to achieve high satisfaction with contrast/SNR and good conspicuity of the enhancing findings. The input combination of T1w, T2w, and DWI sequences with three b-values showed the best qualitative performance. Conclusion: vCE breast MRI performance is significantly influenced by input sequences. Quantitative metrics and visual quality of vCE images significantly benefit when a multi b-value DWI is added to morphologic T1w-/T2w-sequences as input for model training. Key Results: The inclusion of diffusion-weighted imaging significantly improves the conspicuity of lesions/non-mass enhancements and satisfaction with the image contrast in virtual contrast-enhanced breast MRI. The quality of virtual contrast-enhanced breast MRI scans benefits from the inclusion of high-resolution morphologic T1-weighted image acquisitions. Quantitative metrics such as the structural similarity index and peak signal-to-noise ratio calculated over the entire breast volume insufficiently reflect variations in lesion/non-mass enhancement’s individual characteristics.