Chris Ehring
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chris Ehring has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Liebert
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
3 shared publications - Dominique Hadler
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
3 shared publications - Frederik Bernd Laun
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
3 shared publications - Hannes Schreiter
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
3 shared publications - Lorenz A. Kapsner
Medical Informatics, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91058 Erlangen, Germany
3 shared publications - Luise Brock
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
3 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by MDPI AG in Tomography
- Vol. 12 (7) , 105
Can AI Detect What Is Not Injected? Evaluation of Lesion Detection in Virtual Contrast-Enhanced Breast MRI Using a Large-Scale AI Model Trained on GBCA-Enhanced Data
Background/Objectives: Artificial intelligence (AI) can support lesion detection in gadolinium-based contrast agent-enhanced (GBCA-enhanced) breast MRI. However, its effectiveness on virtual contrast-enhanced (vCE) images remains unclear. This feasibility study evaluated the publicly available MAMA-MIA nnU-Net model trained on GBCA-enhanced data using an independent cohort of both GBCA-enhanced and vCE breast MRI. Methods: This IRB-approved retrospective study included the publicly available nnU-Net model trained on n = 1506 MAMA-MIA breast MRI scans and a cohort of n = 2126 in-house 3T breast MRI scans. A generative adversarial network (Pix2Pix-GAN) was developed on n = 1870 of the in-house scans and used to generate vCE data on the remaining independent n = 256 in-house cases. The MAMA-MIA nnU-net was applied to both GBCA-enhanced (GBCA) and corresponding vCE images. Ground-truth segmentations of malignant lesions served to calculate the Dice score, Hausdorff distance, and lesion dimension differences. Results: The final test set comprised n = 250 cases (n = 69 malignant, n = 181 benign). Lesion detection rates were 91% (n = 63/n = 69; 95% confidence interval (CI): 82.3–96.0%) for GBCA and 84% (n = 58/n = 69; 95% CI: 73.7–90.9%) for vCE. Two lesions missed in GBCA were identified by vCE. The Hausdorff distances were similar (GBCA: 6.4 (IQR: 3.2–9.3; 95% CI: 5.2–7.8) mm; vCE: 6.7 (IQR: 3.9–9.7; 95% CI: 5.3–8.0) mm, p = 0.564). The Dice scores showed minor differences (GBCA: 0.829 (IQR: 0.723–0.900; 95% CI: 0.786–0.865) vs. vCE: 0.826 (IQR: 0.720–0.857; 95% CI: 0.770–0.836); p < 0.001). vCE images had slightly higher non-target tissue segmentation (median 6072 mm3 vs. 5754 mm3). Conclusions: A GBCA-trained algorithm demonstrated some cross-domain transferability to vCE images, albeit with a reduced case-level sensitivity of 84% (95% CI: 73.7–90.9%) vs. 91% (95% CI: 82.3–96.0%). Based on these preliminary results, further research, including larger cohorts and more diverse datasets, is warranted.
- 16 July 2026
- Published by MDPI AG in Tomography
- Vol. 12 (7) , 105
Open AccessCan AI Detect What Is Not Injected? Evaluation of Lesion Detection in Virtual Contrast-Enhanced Breast MRI Using a Large-Scale AI Model Trained on GBCA-Enhanced Data
Background/Objectives: Artificial intelligence (AI) can support lesion detection in gadolinium-based contrast agent-enhanced (GBCA-enhanced) breast MRI. However, its effectiveness on virtual contrast-enhanced (vCE) images remains unclear. This feasibility study evaluated the publicly available MAMA-MIA nnU-Net model trained on GBCA-enhanced data using an independent cohort of both GBCA-enhanced and vCE breast MRI. Methods: This IRB-approved retrospective study included the publicly available nnU-Net model trained on n = 1506 MAMA-MIA breast MRI scans and a cohort of n = 2126 in-house 3T breast MRI scans. A generative adversarial network (Pix2Pix-GAN) was developed on n = 1870 of the in-house scans and used to generate vCE data on the remaining independent n = 256 in-house cases. The MAMA-MIA nnU-net was applied to both GBCA-enhanced (GBCA) and corresponding vCE images. Ground-truth segmentations of malignant lesions served to calculate the Dice score, Hausdorff distance, and lesion dimension differences. Results: The final test set comprised n = 250 cases (n = 69 malignant, n = 181 benign). Lesion detection rates were 91% (n = 63/n = 69; 95% confidence interval (CI): 82.3–96.0%) for GBCA and 84% (n = 58/n = 69; 95% CI: 73.7–90.9%) for vCE. Two lesions missed in GBCA were identified by vCE. The Hausdorff distances were similar (GBCA: 6.4 (IQR: 3.2–9.3; 95% CI: 5.2–7.8) mm; vCE: 6.7 (IQR: 3.9–9.7; 95% CI: 5.3–8.0) mm, p = 0.564). The Dice scores showed minor differences (GBCA: 0.829 (IQR: 0.723–0.900; 95% CI: 0.786–0.865) vs. vCE: 0.826 (IQR: 0.720–0.857; 95% CI: 0.770–0.836); p < 0.001). vCE images had slightly higher non-target tissue segmentation (median 6072 mm3 vs. 5754 mm3). Conclusions: A GBCA-trained algorithm demonstrated some cross-domain transferability to vCE images, albeit with a reduced case-level sensitivity of 84% (95% CI: 73.7–90.9%) vs. 91% (95% CI: 82.3–96.0%). Based on these preliminary results, further research, including larger cohorts and more diverse datasets, is warranted.
- Open Access
Feasibility to virtually generate T2 fat-saturated breast MRI by convolutional neural networks
Background Breast magnetic resonance imaging (MRI) protocols often include T2-weighted fat-saturated (T2w-FS) sequences, which are vital for tissue characterization but significantly increase scan time. Purpose This study aims to evaluate whether a 2D-U-Net neural network can generate virtual T2w-FS images from routine multiparametric breast MRI sequences. Materials and Methods This IRB approved, retrospective study included n=914 breast MRI examinations performed between January 2017 and June 2020. The dataset was divided into training (n=665), validation (n=74), and test sets (n=175). The U-Net was trained on T1-weighted (T1w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) sequences to generate virtual T2w-FS images (VirtuT2). Quantitative metrics and a qualitative multi-reader assessment by two radiologists were used to evaluate the VirtuT2 images. Results VirtuT2 images demonstrated high structural similarity (SSIM=0.87) and peak signal-to-noise ratio (PSNR=24.90) compared to original T2w-FS images. High level of the frequency error norm (HFNE=0.87) indicates strong blurring presence in the VirtuT2 images, which was also confirmed in qualitative reading. Radiologists correctly identified VirtuT2 images with 92.3% and 94.2% accuracy, respectively. No significant difference in diagnostic image quality (DIQ) was noted for one reader (p=0.21), while the other reported significantly lower DIQ for VirtuT2 (p<=0.001). Moderate inter-reader agreement was observed for edema detection on T2w-FS images (ƙ=0.43), decreasing to fair on VirtuT2 images (ƙ=0.36). Conclusion The 2D-U-Net can technically generate virtual T2w-FS images with high similarity to real T2w-FS images, though blurring remains a limitation. Further investigation of other architectures and using larger datasets are needed to improve clinical applicability. Summary Statement Virtual T2-weighted fat-saturated images can be generated from routine breast MRI sequences using convolutional neural networks, showing high structural similarity but with notable blurring, necessitating further refinement for clinical use. Key Results Images with T2w-FS characteristics can be virtually generated from T1w and DWI images using deep learning Image blurring occurring in the VirtuT2 image limit clinical use for the current moment Further investigation of different architectures and with larger datasets are necessary in the future to improve the VirtuT2 performance.
Open AccessFeasibility to virtually generate T2 fat-saturated breast MRI by convolutional neural networks
Background Breast magnetic resonance imaging (MRI) protocols often include T2-weighted fat-saturated (T2w-FS) sequences, which are vital for tissue characterization but significantly increase scan time. Purpose This study aims to evaluate whether a 2D-U-Net neural network can generate virtual T2w-FS images from routine multiparametric breast MRI sequences. Materials and Methods This IRB approved, retrospective study included n=914 breast MRI examinations performed between January 2017 and June 2020. The dataset was divided into training (n=665), validation (n=74), and test sets (n=175). The U-Net was trained on T1-weighted (T1w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) sequences to generate virtual T2w-FS images (VirtuT2). Quantitative metrics and a qualitative multi-reader assessment by two radiologists were used to evaluate the VirtuT2 images. Results VirtuT2 images demonstrated high structural similarity (SSIM=0.87) and peak signal-to-noise ratio (PSNR=24.90) compared to original T2w-FS images. High level of the frequency error norm (HFNE=0.87) indicates strong blurring presence in the VirtuT2 images, which was also confirmed in qualitative reading. Radiologists correctly identified VirtuT2 images with 92.3% and 94.2% accuracy, respectively. No significant difference in diagnostic image quality (DIQ) was noted for one reader (p=0.21), while the other reported significantly lower DIQ for VirtuT2 (p<=0.001). Moderate inter-reader agreement was observed for edema detection on T2w-FS images (ƙ=0.43), decreasing to fair on VirtuT2 images (ƙ=0.36). Conclusion The 2D-U-Net can technically generate virtual T2w-FS images with high similarity to real T2w-FS images, though blurring remains a limitation. Further investigation of other architectures and using larger datasets are needed to improve clinical applicability. Summary Statement Virtual T2-weighted fat-saturated images can be generated from routine breast MRI sequences using convolutional neural networks, showing high structural similarity but with notable blurring, necessitating further refinement for clinical use. Key Results Images with T2w-FS characteristics can be virtually generated from T1w and DWI images using deep learning Image blurring occurring in the VirtuT2 image limit clinical use for the current moment Further investigation of different architectures and with larger datasets are necessary in the future to improve the VirtuT2 performance.
- Open Access
Impact of Non-Contrast Enhanced Imaging Input Sequences on the Generation of Virtual Contrast-Enhanced Breast MRI Scans using Neural Networks
Background: Virtual contrast-enhanced (vCE) imaging techniques are an emerging topic of research in breast MRI. Purpose: To investigate how different combinations of T1-weighted (T1w), T2-weighted (T2w), and diffusion-weighted imaging (DWI) impact the performance of vCE breast MRI. Materials and Methods: The IRB-approved, retrospective study included 1064 multiparametric breast MRI scans (age:52±12 years) obtained from 2017-2020 (single site, two 3T MRI). Eleven independent neural networks were trained to derive vCE images from varying input combinations of T1w, T2w, and multi-b-value DWI sequences (b-value=50–1500s/mm 2 ). Three readers evaluated the vCE images with regards to qualitative scores of diagnostic image quality, image sharpness, satisfaction with contrast/signal-to-noise-ratio, and lesion/non-mass enhancement conspicuity. Quantitative metrics (SSIM, PSNR, NRMSE, and median symmetrical accuracy) were analyzed and statistically compared between the input combinations for the full breast volume and both enhancing and non-enhancing target findings. Results: The independent test set consisted of 187 cases. The quantitative metrics significantly improved in target findings when multi-b-value DWI sequences were included during vCE training (p<.05). Non-significant effects (p>.05) were observed for the quantitative metrics on the full breast volume when comparing input combinations including T1w. Using T1w and DWI acquisitions during vCE training is necessary to achieve high satisfaction with contrast/SNR and good conspicuity of the enhancing findings. The input combination of T1w, T2w, and DWI sequences with three b-values showed the best qualitative performance. Conclusion: vCE breast MRI performance is significantly influenced by input sequences. Quantitative metrics and visual quality of vCE images significantly benefit when a multi b-value DWI is added to morphologic T1w-/T2w-sequences as input for model training. Key Results: The inclusion of diffusion-weighted imaging significantly improves the conspicuity of lesions/non-mass enhancements and satisfaction with the image contrast in virtual contrast-enhanced breast MRI. The quality of virtual contrast-enhanced breast MRI scans benefits from the inclusion of high-resolution morphologic T1-weighted image acquisitions. Quantitative metrics such as the structural similarity index and peak signal-to-noise ratio calculated over the entire breast volume insufficiently reflect variations in lesion/non-mass enhancement’s individual characteristics.
Open AccessImpact of Non-Contrast Enhanced Imaging Input Sequences on the Generation of Virtual Contrast-Enhanced Breast MRI Scans using Neural Networks
Background: Virtual contrast-enhanced (vCE) imaging techniques are an emerging topic of research in breast MRI. Purpose: To investigate how different combinations of T1-weighted (T1w), T2-weighted (T2w), and diffusion-weighted imaging (DWI) impact the performance of vCE breast MRI. Materials and Methods: The IRB-approved, retrospective study included 1064 multiparametric breast MRI scans (age:52±12 years) obtained from 2017-2020 (single site, two 3T MRI). Eleven independent neural networks were trained to derive vCE images from varying input combinations of T1w, T2w, and multi-b-value DWI sequences (b-value=50–1500s/mm 2 ). Three readers evaluated the vCE images with regards to qualitative scores of diagnostic image quality, image sharpness, satisfaction with contrast/signal-to-noise-ratio, and lesion/non-mass enhancement conspicuity. Quantitative metrics (SSIM, PSNR, NRMSE, and median symmetrical accuracy) were analyzed and statistically compared between the input combinations for the full breast volume and both enhancing and non-enhancing target findings. Results: The independent test set consisted of 187 cases. The quantitative metrics significantly improved in target findings when multi-b-value DWI sequences were included during vCE training (p<.05). Non-significant effects (p>.05) were observed for the quantitative metrics on the full breast volume when comparing input combinations including T1w. Using T1w and DWI acquisitions during vCE training is necessary to achieve high satisfaction with contrast/SNR and good conspicuity of the enhancing findings. The input combination of T1w, T2w, and DWI sequences with three b-values showed the best qualitative performance. Conclusion: vCE breast MRI performance is significantly influenced by input sequences. Quantitative metrics and visual quality of vCE images significantly benefit when a multi b-value DWI is added to morphologic T1w-/T2w-sequences as input for model training. Key Results: The inclusion of diffusion-weighted imaging significantly improves the conspicuity of lesions/non-mass enhancements and satisfaction with the image contrast in virtual contrast-enhanced breast MRI. The quality of virtual contrast-enhanced breast MRI scans benefits from the inclusion of high-resolution morphologic T1-weighted image acquisitions. Quantitative metrics such as the structural similarity index and peak signal-to-noise ratio calculated over the entire breast volume insufficiently reflect variations in lesion/non-mass enhancement’s individual characteristics.