SSSuguru Sato

Suguru Sato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Suguru Sato has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Flexible Ultrasound Imaging Probe With Sub-Millimeter Element Pitch on Glass Fabric Using Xurography

    by Naoto Tomita, Suguru Sato, Takumi Noda, Michitaka Yamamoto, Takashi Azuma, Naoki Tomii, Ichiro Sakuma, Toshihiro Itoh, Seiichi Takamatsu

    Wearable ultrasound probes that enable non-invasive, continuous monitoring of internal body tissues have attracted increasing attention. Among various approaches, fabric-based probes are particularly promising due to their inherent flexibility, durability, and potential for seamless integration into garments. However, implementing high-density ultrasound arrays on fabric remains technically challenging, primarily due to the difficulty in forming reduced-pitch electrical wiring, which degrades imaging quality. In this study, we propose a novel fabrication approach using xurography, a wiring formation technique, to create tightly pitched electrical wiring on fabric. Furthermore, choosing glass fabric as the substrate—owing to its high mechanical and thermal resilience—enhanced the durability of the wiring; the fabricated wiring maintained stable resistance over 1,000 bending cycles. Using this method, we developed a 16-element flexible ultrasound probe with a 600 μm element pitch on a glass fabric. In imaging experiments with tissue-mimicking phantoms, the probe clearly visualized string targets and simulated blood vessels. The signal-to-noise ration of string targets improved by up to 6.3 dB, and the contrast-to-noise ratio for the vessel improved by 5.3 dB compared to previous design. These results demonstrate that the proposed approach overcomes the limitations of previous fabric-based probes and has potential for wearable healthcare applications.


  • Polyurethane Foam Embedded Pressure Sensor Array With 3-D Printed Structure and Thin MEMS Strain Gauge for Car Seat

    by Suguru Sato, Junya Nakagawa, Michitaka Yamamoto, Seiichi Takamatsu, Takeshi Kobayashi, Toshihiro Itoh

    We have developed a car seat with a pressure sensor array embedded under polyurethane (PU) foam to monitor the posture and driving behavior of the drivers. Each pressure sensor consists of a 5-μm-thick piezoresistive micro-electro-mechanical systems (MEMS) strain gauge wired on a 3D printed parallel-plate cantilever. A cover is attached on top of the cantilever pressure sensor to concentrate the pressure applied through the PU foam, and it is surrounded by a plastic frame of the same height to prevent geometric nonlinear pressure sensor characteristics. To monitor drivers, the proposed 4 × 4 pressure sensor array is embedded under the PU foam of a car seat. The pressure sensor has a sensitivity range of 0–20 kPa and a determination coefficient of the sensor’s regression line of 0.99, which exhibits high linearity. Our evaluation using the prototype sensor array and a driving simulator demonstrated that driver posture changes and braking behavior could be detected. The sensor array is expected to be applied to smart car seats for automated vehicles in the future.


  • Open Access

    Wearable EMG Measurement Device Using Polyurethane Foam for Motion Artifact Suppression

    by Takuma Takagi, Naoto Tomita, Suguru Sato, Michitaka Yamamoto, Seiichi Takamatsu, Toshihiro Itoh

    We propose the use of a specially designed polyurethane foam with a plateau region in its mechanical characteristics—where stress remains nearly constant during deformation—between the electromyography (EMG) electrode and clothing to suppress motion artifacts in EMG measurement. Wearable EMG devices are receiving attention for monitoring muscle weakening due to aging. However, daily EMG measurement has been challenging due to motion artifacts caused by changes in the contact pressure between the bioelectrode and the skin. Therefore, this study aims to measure EMG signals in daily movement environments by controlling the contact pressure using polyurethane foam between the bioelectrode on the clothing and the skin. Through mechanical calculations and finite element method simulations of the polyurethane foam’s effect, we clarified that the characteristics of the polyurethane foam significantly influence contact pressure control and that the contact pressure is adjustable through the polyurethane foam thickness. The optimization of the design successfully controlled the contact pressure between the bioelectrode and skin from 1.0 kPa to 2.0 kPa, effectively suppressing the motion artifact in EMG measurement.