Horace R. Gillins
Research Subjects
Horace R. Gillins has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Charles R. Bridges
CorVista Health
2 shared publications - Farhad Fathieh
Analytics for Life, Toronto, ON M5X 1C9, Canada
2 shared publications - Ian P. Shadforth
CorVista Health, Bethesda, USA
2 shared publications - Navid Nemati
Analytics for Life, Toronto, ON M5X 1C9, Canada
2 shared publications - Shyam Ramchandani
Analytics for Life, Toronto, ON M5X 1C9, Canada
2 shared publications - Timothy Burton
Analytics for Life, Toronto, Canada
2 shared publications
Latest Publications
- Open Access
- 17 March 2025
- Published by Springer Nature in Discover Medicine
- Vol. 2 (1) , 1-11
Efficacy of a US-developed machine-learned coronary artery disease algorithm in China
Background: Cardiac computed tomography angiography (CCTA), the premier coronary artery disease (CAD) rule-out test, is less available in rural areas (vs urban) in the US. To address this gap, we previously developed a test using non-invasive signals and a machine-learned algorithm, usable anywhere with internet. We trained the algorithm using US populations: (1) subjects enrolled before CCTA for specificity and (2) subjects undergoing invasive coronary angiography (ICA), for both sensitivity and specificity. US validation used separate, identically constructed, blinded populations (N = 1816). In US validation, sensitivity was 88% (95% CI 85–91%) and specificity was 51% (48–55%). Although China is urbanizing rapidly, 510 million (36% of the population) still reside in rural areas. Thus, China might benefit from the test, but given the demographic differences, the efficacy of the test in the Chinese population is unknown. The aim of the present study was to assess test performance within a cohort of Chinese ICA subjects. Methods: Subjects were enrolled at Zhongshan Hospital, Fudan University (China), using the same inclusion and exclusion criteria as in the US study. The same device as in the US captured signals pre-ICA. We applied the unchanged algorithm from US validation to the signals, then matched with the ICA results. Results: 558 subjects had both ICA results and a signal, 458 passed signal quality and outlier checks, and 348 had significant CAD. Compared to the US sensitivity cohort, the Chinese cohort was significantly younger, had a lower BMI, a higher proportion of males, and lower rates of tobacco use, hypertension, and diabetes. Race was Asian only in China, while the US was primarily White/Caucasian. Chinese cohort sensitivity was 89% (86–93%), p = 0.46 vs the US. Discussion: Our study was limited by the lack of a Chinese CCTA specificity cohort. However, sensitivity was high, and thus robust to the significant demographic shifts. Therefore, we anticipate similar behavior in specificity; to explore that, we combined the Chinese ICA negatives (N = 110) with the US CCTA negatives from the previous work, in the same proportion as used in US validation, which models the population of patients under assessment for cardiac symptoms. The resultant specificity was 51% (48–55%). With the Chinese ICA positives, the area under the receiver operator characteristic curve was 0.79 (0.77–0.81). These results suggest the test’s potential effectiveness in the Chinese population. Trial registration: NCT04034537.
- 17 March 2025
- Published by Springer Nature in Discover Medicine
- Vol. 2 (1) , 1-11
Open AccessEfficacy of a US-developed machine-learned coronary artery disease algorithm in China
Background: Cardiac computed tomography angiography (CCTA), the premier coronary artery disease (CAD) rule-out test, is less available in rural areas (vs urban) in the US. To address this gap, we previously developed a test using non-invasive signals and a machine-learned algorithm, usable anywhere with internet. We trained the algorithm using US populations: (1) subjects enrolled before CCTA for specificity and (2) subjects undergoing invasive coronary angiography (ICA), for both sensitivity and specificity. US validation used separate, identically constructed, blinded populations (N = 1816). In US validation, sensitivity was 88% (95% CI 85–91%) and specificity was 51% (48–55%). Although China is urbanizing rapidly, 510 million (36% of the population) still reside in rural areas. Thus, China might benefit from the test, but given the demographic differences, the efficacy of the test in the Chinese population is unknown. The aim of the present study was to assess test performance within a cohort of Chinese ICA subjects. Methods: Subjects were enrolled at Zhongshan Hospital, Fudan University (China), using the same inclusion and exclusion criteria as in the US study. The same device as in the US captured signals pre-ICA. We applied the unchanged algorithm from US validation to the signals, then matched with the ICA results. Results: 558 subjects had both ICA results and a signal, 458 passed signal quality and outlier checks, and 348 had significant CAD. Compared to the US sensitivity cohort, the Chinese cohort was significantly younger, had a lower BMI, a higher proportion of males, and lower rates of tobacco use, hypertension, and diabetes. Race was Asian only in China, while the US was primarily White/Caucasian. Chinese cohort sensitivity was 89% (86–93%), p = 0.46 vs the US. Discussion: Our study was limited by the lack of a Chinese CCTA specificity cohort. However, sensitivity was high, and thus robust to the significant demographic shifts. Therefore, we anticipate similar behavior in specificity; to explore that, we combined the Chinese ICA negatives (N = 110) with the US CCTA negatives from the previous work, in the same proportion as used in US validation, which models the population of patients under assessment for cardiac symptoms. The resultant specificity was 51% (48–55%). With the Chinese ICA positives, the area under the receiver operator characteristic curve was 0.79 (0.77–0.81). These results suggest the test’s potential effectiveness in the Chinese population. Trial registration: NCT04034537.
- Open Access
- 8 May 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (10) , 987
Clinical Validation of a Machine-Learned, Point-of-Care System to IDENTIFY Functionally Significant Coronary Artery Disease
Many clinical studies have shown wide performance variation in tests to identify coronary artery disease (CAD). Coronary computed tomography angiography (CCTA) has been identified as an effective rule-out test but is not widely available in the USA, particularly so in rural areas. Patients in rural areas are underserved in the healthcare system as compared to urban areas, rendering it a priority population to target with highly accessible diagnostics. We previously developed a machine-learned algorithm to identify the presence of CAD (defined by functional significance) in patients with symptoms without the use of radiation or stress. The algorithm requires 215 s temporally synchronized photoplethysmographic and orthogonal voltage gradient signals acquired at rest. The purpose of the present work is to validate the performance of the algorithm in a frozen state (i.e., no retraining) in a large, blinded dataset from the IDENTIFY trial. IDENTIFY is a multicenter, selectively blinded, non-randomized, prospective, repository study to acquire signals with paired metadata from subjects with symptoms indicative of CAD within seven days prior to either left heart catheterization or CCTA. The algorithm’s sensitivity and specificity were validated using a set of unseen patient signals (n = 1816). Pre-specified endpoints were chosen to demonstrate a rule-out performance comparable to CCTA. The ROC-AUC in the validation set was 0.80 (95% CI: 0.78–0.82). This performance was maintained in both male and female subgroups. At the pre-specified cut point, the sensitivity was 0.85 (95% CI: 0.82–0.88), and the specificity was 0.58 (95% CI: 0.54–0.62), passing the pre-specified endpoints. Assuming a 4% disease prevalence, the NPV was 0.99. Algorithm performance is comparable to tertiary center testing using CCTA. Selection of a suitable cut-point results in the same sensitivity and specificity performance in females as in males. Therefore, a medical device embedding this algorithm may address an unmet need for a non-invasive, front-line point-of-care test for CAD (without any radiation or stress), thus offering significant benefits to the patient, physician, and healthcare system.
- 8 May 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (10) , 987
Open AccessClinical Validation of a Machine-Learned, Point-of-Care System to IDENTIFY Functionally Significant Coronary Artery Disease
Many clinical studies have shown wide performance variation in tests to identify coronary artery disease (CAD). Coronary computed tomography angiography (CCTA) has been identified as an effective rule-out test but is not widely available in the USA, particularly so in rural areas. Patients in rural areas are underserved in the healthcare system as compared to urban areas, rendering it a priority population to target with highly accessible diagnostics. We previously developed a machine-learned algorithm to identify the presence of CAD (defined by functional significance) in patients with symptoms without the use of radiation or stress. The algorithm requires 215 s temporally synchronized photoplethysmographic and orthogonal voltage gradient signals acquired at rest. The purpose of the present work is to validate the performance of the algorithm in a frozen state (i.e., no retraining) in a large, blinded dataset from the IDENTIFY trial. IDENTIFY is a multicenter, selectively blinded, non-randomized, prospective, repository study to acquire signals with paired metadata from subjects with symptoms indicative of CAD within seven days prior to either left heart catheterization or CCTA. The algorithm’s sensitivity and specificity were validated using a set of unseen patient signals (n = 1816). Pre-specified endpoints were chosen to demonstrate a rule-out performance comparable to CCTA. The ROC-AUC in the validation set was 0.80 (95% CI: 0.78–0.82). This performance was maintained in both male and female subgroups. At the pre-specified cut point, the sensitivity was 0.85 (95% CI: 0.82–0.88), and the specificity was 0.58 (95% CI: 0.54–0.62), passing the pre-specified endpoints. Assuming a 4% disease prevalence, the NPV was 0.99. Algorithm performance is comparable to tertiary center testing using CCTA. Selection of a suitable cut-point results in the same sensitivity and specificity performance in females as in males. Therefore, a medical device embedding this algorithm may address an unmet need for a non-invasive, front-line point-of-care test for CAD (without any radiation or stress), thus offering significant benefits to the patient, physician, and healthcare system.