DBDevasish Bose

Devasish Bose

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Devasish Bose has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Use of Micellar Liquid Chromatography to Determine Mebendazole in Dairy Products and Breeding Waste from Bovine Animals

    by Rajendra Prasad Pawar, Pooja Mishra, Abhilasha Durgbanshi, Devasish Bose, Jaume Albiol-Chiva, Juan Peris-Vicente, Daniel García-Ferrer, Josep Esteve-Romero

    Mebendazole is an anthelmintic drug used in cattle production. However, residues may occur in produced food and in excretions, jeopardizing population health. A method based on micellar liquid chromatography (MLC) was developed to determine mebendazole in dairy products (milk, cheese, butter, and curd) and nitrogenous waste (urine and dung) from bovine animals. Sample treatment was expedited to simple dilution or solid-to-liquid extraction, followed by filtration and direct injection of the obtained solution. The analyte was resolved from matrix compounds in less than 8 min, using a C18 column and a mobile phase made up of 0.15 M sodium dodecyl sulfate (SDS)–6% 1-pentanol phosphate buffered at pH 7, and running at 1 mL/min under isocratic mode. Detection was performed by absorbance at 292 nm. The procedure was validated according to the guidelines of the EU Commission Decision 2002/657/EC in terms of: specificity, method calibration range (from the limit of quantification to 25–50 ppm), sensitivity (limit of detection 0.1–0.2 ppm; limit of quantification, 0.3–0.6 ppm), trueness (92.5–102.3%), precision (<7.5%, expressed at RSD), robustness, and stability. The method is reliable, sensitive, easy-to-handle, eco-friendly, safe, inexpensive, and provides a high sample-throughput. Therefore, it is useful for routine analysis as a screening or quantification method in a laboratory for drug-residue control.


  • Open Access

    Procedure for the Screening of Eggs and Egg Products to Detect Oxolonic Acid, Ciprofloxacin, Enrofloxacin, and Sarafloxacin Using Micellar Liquid Chromatography

    by Juan Peris-Vicente, Daniel García-Ferrer, Pooja Mishra, Jaume Albiol-Chiva, Abhilasha Durgbanshi, Samuel Carda-Broch, Devasish Bose, Josep Esteve-Romero

    A method based on micellar liquid chromatography was developed to determine oxolinic acid, ciprofloxacin, enrofloxacin, and sarafloxacin in eggs and egg products. The antimicrobial drugs were obtained in a micellar solution which was directly injected. The analytes were resolved using a C18 column and a mobile phase of 0.05 M sodium dodecyl sulfate—7.5% 1-propanol—0.5% triethylamine, buffered at pH 3 with phosphate salt, running under the isocratic mode. The signal was monitored by fluorescence. Validation was successfully performed according to the EU Commission Decision 2002/657/EC in terms of specificity, calibration range (LOQ to 1 mg/kg), linearity (R2 > 0.9991), limit of detection and decision limit (0.01–0.05 mg/kg), limit of quantification (0.025–0.150 mg/kg), detection capability (<0.4 times decision limit), trueness (−14.2% to +9.8%), precision (<14.0%), robustness, and stability. The procedure was environmentally friendly, safe, easy-to-conduct, inexpensive, and had a high sample throughput, thus it is useful for routine analysis as a screening method in a laboratory for food residue control.


  • Open Access

    Optimization and Validation of a Chromatographic Method for the Quantification of Isoniazid in Urine of Tuberculosis Patients According to the European Medicines Agency Guideline

    by Pooja Mishra, Jaume Albiol-Chiva, Devasish Bose, Abhilasha Durgbanshi, Juan Peris-Vicente, Samuel Carda-Broch, Josep Esteve-Romero

    Isoniazid is a drug that is widely used against tuberculosis. However, it shows high interpatient variability in metabolism kinetics and clinical effect, which complicates the prescription of the medication and jeopardizes the success of the therapy. Therefore, in a specific patient, the pharmacokinetics of the drug must be elucidated to decide the proper dosage and intake frequency to make the drug suitable for therapeutic drug monitoring. This can be performed by the quantification of the drug in urine as this process is non-invasive and allows the effects of long-time exposure to be inferred. The paper describes the development of a micellar liquid chromatographic method to quantify isoniazid in urine samples. Extraction steps were avoided, making the procedure easy to handle and reducing the waste of toxic organic solvents. Isoniazid was eluted in less than 5 min without interference from other compounds of the urine using a mobile phase containing 0.15 SDS–12.5% 1-propanol (v/v)–Na2HPO4 0.01 M buffered at pH 7, running at 1 mL/min under isocratic mode through a C18 column with the detection wavelength at 265 nm. The method was validated by following the requirements of the Guidelines on Bioanalytical Method Validation issued by the European Medicines Agency (EMA) in terms of selectivity, calibration curve (r2 = 0.9998 in the calibration range (0.03–10.0 μg/mL), limit of detection and quantification (10 and 30 ng/mL respectively), precision (<16.0%), accuracy (−0.9 to +8.5%), carry-over, matrix effect, and robustness. The developed method was applied to quantify isoniazid in urine samples of patients of an Indian hospital with good results. The method was found to be useful for routine analysis to check the amount of isoniazid in these patients and could be used in its therapeutic monitoring.