JMJorge Muñiz-Rosado

Jorge Muñiz-Rosado

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jorge Muñiz-Rosado has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of ceilometer aerosol profile retrievals using sun–sky photometer and balloon-borne in situ measurements

    by Jorge Muñiz-Rosado, Alberto Cazorla, Eric Sauvageat, Alexander Haefele, Celia Herrero del Barrio, Ramiro González, Roberto Román, Pedro Luis Molina-Molero, Arlett Díaz-Zurita, Víctor Manuel Naval-Hernández, et al.

    This study evaluates two approaches for retrieving aerosol properties from ceilometer observations, using aerosol optical depth (AOD) from AERONET and synergistic aerosol profiles obtained by combining the AERONET sun–sky photometer and ceilometer measurements through the GRASP pac algorithm. The two retrieval techniques considered for the ceilometer retrievals are the traditional Klett–Fernald backward inversion and a forward iterative method including an independent calibration procedure. Observations collected at three European stations (Granada, Spain; Payerne, Switzerland; and Lindenberg, Germany) during 2019–2020 are analyzed to assess the performance of both approaches under a wide range of aerosol conditions. The results show that the forward iterative approach generally provides better agreement with the reference datasets than the Klett–Fernald backward approach. Under high aerosol load conditions, particularly during coarse-mode-dominated events, the forward retrieval reduces AOD uncertainties by ∼50 % and achieves root-mean-square errors comparable to those reported in previous validation studies. Vertical comparisons against GRASP pac profiles indicate that the forward method maintains consistent accuracy throughout the troposphere, whereas the backward approach exhibits altitude-dependent biases, especially within dust layers. Additional evaluations using COBALD balloon-borne backscatter measurements confirm that the forward retrieval reproduces observed aerosol structures within 10 %–30 % deviation. These results demonstrate the significant performance gains achieved by operational ceilometer networks when applying forward retrievals with independent calibration made under nighttime cloud-free conditions with negligible aerosol loading at the reference altitude.

  • Open Access

    Reply on RC1

    by Jorge Muñiz Rosado

  • Open Access

    Reply on RC2

    by Jorge Muñiz Rosado

  • Open Access

    Hybrid methodology for optimised water vapour mixing ratio profiles from Raman lidar measurements

    by Arlett Díaz-Zurita, Daniel Pérez-Ramírez, David N. Whiteman, Onel Rodríguez-Navarro, Víctor M. Naval-Hernández, Jorge Muñiz-Rosado, Soledad Fernández-Carvelo, Jesús Abril-Gago, Ana del Águila, Pablo Ortiz-Amezcua, et al.

    This study presents a hybrid methodology to obtain high temporal resolution calibration constants for water vapour Raman lidar measurements, and posteriorly retrieve high-accuracy water vapour mixing ratio profiles. The hybrid method combines correlative measurements of collocated precipitable water vapour and Numerical Weather Prediction data to reconstruct the profile within the incomplete overlap region. The hybrid methodology is applied to the Raman lidar system, which operated at the EARLINET/ACTRIS station of the University of Granada, Spain, for the period 2009–2022. The system has been continuously updated to meet EARLINET/ACTRIS requirements for aerosol measurements, but the hybrid method has allowed tracking the impact of these changes on calibration constants for water vapour retrievals, and consequently to exploit water vapour mixing ratio profiles that were previously unavailable. The hybrid method was optimised for the Granada station by selecting Global Navigation Satellite System precipitable water vapour data as the most appropriate due to its better agreement with collocated and simultaneous radiosonde data (coefficient of determination of 0.95). Furthermore, the ERA5 reanalysis model was selected as the most appropriate because of its better temporal and spatial resolution and its accuracy when evaluated against radiosonde data. The advantages of the hybrid methodology were evaluated in comparison to traditional calibration methods such as those based on radiosondes or precipitable water vapour data assuming a constant water vapour mixing ratio in the incomplete overlap region. Although all methods generally provided good calibration constants, the hybrid method presented the best assessments under conditions where atmospheric layers were not well-mixed. Comparison with radiosonde data revealed excellent agreement, with a mean bias of −0.1 ± 0.3 g kg−1, a standard deviation of 1.0 ± 0.4 g kg−1 and a coefficient of determination of 0.87 across the entire period and vertical range (0–6 kma.g.l. ). The most important result of this study is the ability to continuously evaluate calibration constants in a system that its configuration has been changing over 14 years of operation. This new methodology expanded the dataset from 31 initial cases using collocated radiosondes to more than 2000 values through the hybrid methodology. The posterior application of the hybrid methodology to all Raman lidar measurements enabled the generation of a comprehensive database of water vapour mixing ratio profiles for the entire period 2009–2022. Illustrative cases under different atmospheric conditions are presented to showcase the potential of Raman lidar measurements in monitoring water vapour and to investigate its role in climate dynamics and weather prediction.

  • Open Access

    Comment on egusphere-2026-990

    by Jorge Muñiz-Rosado, Alberto Cazorla, Eric Sauvageat, Alexander Haefele, Celia Herrero del Barrio, Ramiro González, Roberto Román, Pedro Luis Molina-Molero, Arlett Díaz-Zurita, Victor Manuel Naval-Hernández, et al.

    This study evaluates two approaches for retrieving aerosol properties from ceilometer observations, using aerosol optical depth (AOD) from AERONET and synergistic aerosol profiles obtained by combining AERONET sun–sky photometer and ceilometer measurements through the GRASPpac algorithm as reference. The two retrieval techniques considered for the ceilometer retrievals are the traditional Klett-Fernald backward inversion and a forward iterative method including an independent calibration procedure. Observations collected at three European stations (Granada, Spain; Payerne, Switzerland; and Lindenberg, Germany) during 2019–2020 are analyzed to assess the performance of both approaches under a wide range of aerosol conditions. The results show that the forward iterative method systematically outperforms the Klett-Fernald backward approach. Under high aerosol load conditions, particularly during coarse-mode-dominated events, the forward retrieval reduces AOD uncertainties by ~50 % and achieves root-mean-square errors comparable to those reported in previous validation studies. Vertical comparisons against GRASPpac profiles indicate that the forward method maintains consistent accuracy throughout the troposphere, whereas the backward approach exhibits altitude-dependent biases, especially within dust layers. Additional evaluations using COBALD balloon-borne backscatter measurements confirm that the forward retrieval reproduces observed aerosol structures within 10–30~\% deviation. These results demonstrate the significant performance gains achieved by operational ceilometer networks when applying forward retrievals with independent calibration under favorable atmospheric conditions.

  • Open Access

    Comment on egusphere-2026-990

    by Jorge Muñiz-Rosado, Alberto Cazorla, Eric Sauvageat, Alexander Haefele, Celia Herrero del Barrio, Ramiro González, Roberto Román, Pedro Luis Molina-Molero, Arlett Díaz-Zurita, Victor Manuel Naval-Hernández, et al.

    This study evaluates two approaches for retrieving aerosol properties from ceilometer observations, using aerosol optical depth (AOD) from AERONET and synergistic aerosol profiles obtained by combining AERONET sun–sky photometer and ceilometer measurements through the GRASPpac algorithm as reference. The two retrieval techniques considered for the ceilometer retrievals are the traditional Klett-Fernald backward inversion and a forward iterative method including an independent calibration procedure. Observations collected at three European stations (Granada, Spain; Payerne, Switzerland; and Lindenberg, Germany) during 2019–2020 are analyzed to assess the performance of both approaches under a wide range of aerosol conditions. The results show that the forward iterative method systematically outperforms the Klett-Fernald backward approach. Under high aerosol load conditions, particularly during coarse-mode-dominated events, the forward retrieval reduces AOD uncertainties by ~50 % and achieves root-mean-square errors comparable to those reported in previous validation studies. Vertical comparisons against GRASPpac profiles indicate that the forward method maintains consistent accuracy throughout the troposphere, whereas the backward approach exhibits altitude-dependent biases, especially within dust layers. Additional evaluations using COBALD balloon-borne backscatter measurements confirm that the forward retrieval reproduces observed aerosol structures within 10–30~\% deviation. These results demonstrate the significant performance gains achieved by operational ceilometer networks when applying forward retrievals with independent calibration under favorable atmospheric conditions.

  • Open Access

    Reply on RC2

    by Arlett Díaz-Zurita, Daniel Pérez-Ramírez, David N. Whiteman, Onel Rodríguez-Navarro, Víctor Manuel Naval-Hernández, Jorge Andrés Muñiz-Rosado, María Soledad Fernández-Carvelo, Jesús Abril-Gago, Ana del Águila, Pablo Ortiz-Amezcua, et al.

    This study presents a hybrid methodology to obtain high temporal resolution calibration constants for water vapour Raman lidar measurements, and posteriorly retrieve high accuracy water vapour mixing ratio profiles. The hybrid method combines correlative measurements of collocated precipitable water vapour and Numerical Weather Prediction data to reconstruct the profile within the incomplete overlap region. The hybrid methodology is applied to the MULHACEN Raman lidar system, which operated at the EARLINET/ACTRIS station of the University of Granada, Spain for the period 2009–2022. The system has been continuously updated to meet EARLINET/ACTRIS requirements for aerosol measurements, but the hybrid method has allowed tracking the impact of these changes on calibration constants for water vapour retrievals, and consequently to exploit water vapour mixing ratio profiles that were previously unavailable. The hybrid method was optimised for the Granada station by selecting Global Navigation Satellite System precipitable water vapour data as the most appropriate due to its better agreement with collocated and simultaneous radiosonde data (coefficient of determination of 0.95). Furthermore, the ERA5 reanalysis model was selected as the most appropriate because of its better temporal and spatial resolution and its accuracy when evaluated against radiosonde data. The advantages of the hybrid methodology were evaluated in comparison to traditional calibration methods such as those based on radiosondes or precipitable water vapour data assuming a constant water vapour mixing ratio in the incomplete overlap region. Although all methods generally provided good calibration constants, the hybrid method presented the best assessments under conditions where atmospheric layers were not well-mixed. Comparison with radiosonde data revealed excellent agreement, with a mean bias of -0.1 ± 0.3 g/kg, a standard deviation of 1.0 ± 0.4 g/kg and a coefficient of determination of 0.87 across the entire period and vertical range (0–6 km agl). The most important result of this study is the ability to continuously evaluate calibration constants in a system that has been changing its configuration over 14 years of operation. This new methodology expanded the dataset from 31 initial cases using collocated radiosondes to more than 2000 values through the hybrid methodology. The posterior application of the hybrid methodology to all MULHACEN measurements enabled the generation of a comprehensive database of water vapour mixing ratio profiles for the entire period 2009–2022. Illustrative cases under different atmospheric conditions are presented to showcase the potential of MULHACEN measurements in monitoring water vapour and to investigate its role in climate dynamics and weather prediction.

  • Open Access

    Comment on egusphere-2025-5035

    by Arlett Díaz-Zurita, Daniel Pérez-Ramírez, David N. Whiteman, Onel Rodríguez-Navarro, Víctor Manuel Naval-Hernández, Jorge Andrés Muñiz-Rosado, María Soledad Fernández-Carvelo, Jesús Abril-Gago, Ana del Águila, Pablo Ortiz-Amezcua, et al.

    This study presents a hybrid methodology to obtain high temporal resolution calibration constants for water vapour Raman lidar measurements, and posteriorly retrieve high accuracy water vapour mixing ratio profiles. The hybrid method combines correlative measurements of collocated precipitable water vapour and Numerical Weather Prediction data to reconstruct the profile within the incomplete overlap region. The hybrid methodology is applied to the MULHACEN Raman lidar system, which operated at the EARLINET/ACTRIS station of the University of Granada, Spain for the period 2009–2022. The system has been continuously updated to meet EARLINET/ACTRIS requirements for aerosol measurements, but the hybrid method has allowed tracking the impact of these changes on calibration constants for water vapour retrievals, and consequently to exploit water vapour mixing ratio profiles that were previously unavailable. The hybrid method was optimised for the Granada station by selecting Global Navigation Satellite System precipitable water vapour data as the most appropriate due to its better agreement with collocated and simultaneous radiosonde data (coefficient of determination of 0.95). Furthermore, the ERA5 reanalysis model was selected as the most appropriate because of its better temporal and spatial resolution and its accuracy when evaluated against radiosonde data. The advantages of the hybrid methodology were evaluated in comparison to traditional calibration methods such as those based on radiosondes or precipitable water vapour data assuming a constant water vapour mixing ratio in the incomplete overlap region. Although all methods generally provided good calibration constants, the hybrid method presented the best assessments under conditions where atmospheric layers were not well-mixed. Comparison with radiosonde data revealed excellent agreement, with a mean bias of -0.1 ± 0.3 g/kg, a standard deviation of 1.0 ± 0.4 g/kg and a coefficient of determination of 0.87 across the entire period and vertical range (0–6 km agl). The most important result of this study is the ability to continuously evaluate calibration constants in a system that has been changing its configuration over 14 years of operation. This new methodology expanded the dataset from 31 initial cases using collocated radiosondes to more than 2000 values through the hybrid methodology. The posterior application of the hybrid methodology to all MULHACEN measurements enabled the generation of a comprehensive database of water vapour mixing ratio profiles for the entire period 2009–2022. Illustrative cases under different atmospheric conditions are presented to showcase the potential of MULHACEN measurements in monitoring water vapour and to investigate its role in climate dynamics and weather prediction.

  • Open Access

    Validation of EarthCARE-Derived Planetary Boundary Layer Height Using the E-Profile Ceilometer Network and Radiosondes

    by Onel Rodríguez-Navarro, Jorge Muñiz-Rosado, Alexander Haefele, Eric Sauvageat, Arlett Díaz-Zurita, Víctor Manuel Naval-Hernández, Alberto Cazorla, Daniel Pérez-Ramírez, Lucas Alados-Arboledas, Francisco Navas-Guzmán

    The Earth Clouds, Aerosol and Radiation Explorer (EarthCARE), launched in May 2024 as a joint ESA–JAXA mission, provides vertically resolved observations of aerosols and clouds with unprecedented sensitivity from space. In this study, we exploit measurements from the Atmospheric Lidar (ATLID), a high-spectral-resolution lidar operating at 355 nm, whose enhanced signal-to-noise ratio and capability to separate molecular and particulate backscatter enable detailed characterization of the lower troposphere (Wehr et al., 2023). These features make ATLID particularly suitable for deriving the planetary boundary layer height (PBLH) at the global scale.The PBL is the atmospheric layer most strongly influenced by surface forcing through turbulent exchanges of heat, moisture and momentum. Accurate estimates of PBLH are therefore essential for weather forecasting, climate modelling and air quality studies. Previous spaceborne lidar missions, notably CALIPSO, demonstrated the feasibility of PBLH retrievals from aerosol backscatter profiles, although with limitations related to signal attenuation, cloud contamination and retrieval robustness (McGrath-Spangler and Denning, 2012). EarthCARE’s ATLID offers enhanced capabilities to address these challenges.We validate ATLID-derived PBLH using independent ground-based observations from the E-Profile network, comprising over 400 ceilometers across Europe, along with collocated radiosonde measurements from the University of Wyoming Upper Air Soundings database. A continental-scale reference dataset was generated by applying the STRATfinder algorithm to ceilometer aerosol backscatter profiles. Planetary boundary layer heights from radiosondes were independently estimated using several thermodynamic and dynamical approaches, including the bulk Richardson number, the parcel method, and gradient-based criteria applied to temperature and humidity profiles. Only radiosonde launches collocated with E-Profile stations were considered, ensuring spatial consistency among the reference datasets. The analysis includes 580 collocated cases, defined as EarthCARE overpasses within 20 km of a ground-based station, from which 25 correspond to radiosonde observation, covering the period from August 2024 to August 2025.Two complementary approaches were assessed to retrieve PBLH from ATLID Level-2 BA baseline products. The first approach used the operational A-ALD product, which includes PBLH as a retrieved variable. The product showed limitations, with misidentification of cloud layers as the PBL and a lack of retrievals under favourable conditions. These results underline current shortcomings of A-ALD for PBL detection, while indicating potential for future algorithm improvements.The second approach applied combined variance–gradient methods to attenuated backscatter profiles from the A-EBD product, supported by cloud screening using the A-FM product. This strategy allowed more robust and physically consistent PBLH estimates. The comparison with ground-based ceilometer references resulted in a standard deviation of 343 m and a mean bias of 101 m. The nearly symmetric uncertainty distribution highlights the reliability of this approach. Radiosonde-based results showed a clear dependence on the retrieval method, with the best performance obtained for gradient-based approaches, although their statistical representativeness is limited by the small number of available cases.These findings highlight the capability of EarthCARE’s ATLID to capture the PBL from space for climatological and modeling applications. The validation also emphasizes the importance of networks such as E-Profile, which provide the necessary reference data to evaluate satellite-derived boundary layer products on a continental scale.

  • Open Access

    Integrated Water Vapour (IWV) trend analysis from GNSS and NWP reanalyses: a homogenised long-term analysis over Granada

    by Victor Manuel Naval Hernández, Arlett Díaz Zurita, Onel Rodríguez Navarro, Jorge Muñiz Rosado, Daniel Pérez Ramírez, David Neil Whiteman, Lucas Alados Arboledas, Francisco Navas Guzmán

    In a context of climate change and global warming, the characterisation and operational monitoring of greenhouse gases is of uppermost importance for implementing mitigation strategies that could help to reduce the impact of the current climatic emergency in the surrounding ecosystems and society. Among these gases, water vapour can contribute to almost a 60% of the total greenhouse effect. Moreover, its interaction with solar and infrared radiation or its main role in cloud formation, make water vapour a key driver of most atmospheric thermodynamic processes and a crucial component of the Earth's radiative budget. Nevertheless, the large spatial and temporal variability of water vapour hinders the acquisition of reliable operational measurements. Remote sensing techniques such as the Global Navigation Satellite System (GNSS) have been proven to be an accurate and trustworthy alternative for integrated water vapour (IWV) retrievals, providing a valuable platform for continuous operational monitoring and thus enabling long-term characterisation. To further address this challenge, reanalysis data from Numerical Weather Prediction (NWP) models can significantly increase the temporal and spatial coverage of atmospheric variables datasets. In particular, ERA5 (fifth generation of European Centre for Medium-Range Weather Forecasts reanalysis) and MERRA-2 (Modern-Era Retrospective Analysis for Research and Applications, version 2) provide validated data for the city of Granada, in southeastern Spain, since 1980.The current study presents a comprehensive analysis of IWV trends retrieved from a 15-year GNSS database and an extended 45-year reanalysis dataset. Special attention is paid to time-series quality control and homogenisation. Small jumps or discontinuities due to GPS receiver updates or changes in the data assimilation strategies of NWP models, can introduce artificial artifacts in the time series and consequently lead to biased or misleading trend esimates. A modified Mann-Kendall test proposed by Coen et al. (2020) that applies a Variance-Corrected Trend-Free Pre-Whitening approach is evaluated against a General Least Square method with a full custom covariance matrix accounting for residual heteroscedasticity and autocorrelation. While both methodologies agree on the sign and uncertainties of the retrieved trends, some discrepancies are found in the magnitudes, reflecting the different nature of both algorithms and highlighting the sensibility of trend detection techniques. Positive increasing IWV trends of a 3% per decade on average were obtained from both datasets and algorithms, being significant to a 95% level when analysing the 45-year time series. Nonetheless, relevant behaviour differences are found between the 1980-2000 and 2000-2024 periods, unveiling the pronounced increasing in IWV experimented during the last 25 years. The results obtained are consistent with previous studies, both regarding the trend magnitude and the uncertainty range, reinforcing the capability of the GNSS technique and NWP models as robust tools for environmental and atmospheric monitoring of complex variables such as water vapour (Parracho et al., 2018; Yuan et al., 2023). However, they also unveil trend discrepancies which are inherent to the chosen retrieval methodologies and that must always be assessed.