Zhongqiang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhongqiang Li has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Jian Xu
Louisiana State University
7 shared publications Alexandra Ramos
Department of Comparative Biomedical Science, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA
5 shared publications- Shaomian Yao
Department of Comparative Biomedical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA
5 shared publications Yanping Li
School of Environment and Sustainability, University of Saskatchewan, Saskatoon, SK S7N 5C9, Canada
5 shared publicationsZheng Li
Division of Electrical and Computer Engineering, College of Engineering, Louisiana State University, Baton Rouge, LA 70803, USA
4 shared publications- Ji Yi
Johns Hopkins University
3 shared publications
Latest Publications
- Open Access
Enhancing volumetric microscopy with blind computational correction of spatially variant aberrations using neural field representation
Studying biological processes across multi-millimeter scales requires imaging systems that combine high spatial resolution with a large field of view (FOV). However, optical aberrations degrade image quality, particularly in large-FOV systems where distortions gradually worsen toward the periphery. Existing methods for correcting field-dependent aberrations are limited and often impractical. Hardware-based solutions such as adaptive optics demand additional components and sample manipulation, increasing system complexity and experimental burden. Computational approaches, while promising, typically rely on exhaustive point spread function (PSF) calibration or large training datasets, restricting their applicability. We introduce a self-supervised algorithm that simultaneously estimates spatially varying aberrations and reconstructs 3D sample structure from a single blurred image—without PSF calibration or training data. Our method was implemented on optically cleared mouse hippocampal neurons and cortical vasculature imaged with oblique plane microscopy (OPM), as well as in vivo mouse retinal vasculature captured with adaptive optics scanning laser ophthalmoscopy (AOSLO), where PSF calibration is infeasible. The algorithm predicts and corrects aberrations across multi-millimeter FOVs, enhances contrast in low signal-to-noise regions, and reveals critical structural details in neuronal and vascular systems that are obscured in raw images. This approach enables high-resolution, large-scale imaging without hardware modifications, expanding the accessibility of advanced microscopy techniques.
Open AccessEnhancing volumetric microscopy with blind computational correction of spatially variant aberrations using neural field representation
Studying biological processes across multi-millimeter scales requires imaging systems that combine high spatial resolution with a large field of view (FOV). However, optical aberrations degrade image quality, particularly in large-FOV systems where distortions gradually worsen toward the periphery. Existing methods for correcting field-dependent aberrations are limited and often impractical. Hardware-based solutions such as adaptive optics demand additional components and sample manipulation, increasing system complexity and experimental burden. Computational approaches, while promising, typically rely on exhaustive point spread function (PSF) calibration or large training datasets, restricting their applicability. We introduce a self-supervised algorithm that simultaneously estimates spatially varying aberrations and reconstructs 3D sample structure from a single blurred image—without PSF calibration or training data. Our method was implemented on optically cleared mouse hippocampal neurons and cortical vasculature imaged with oblique plane microscopy (OPM), as well as in vivo mouse retinal vasculature captured with adaptive optics scanning laser ophthalmoscopy (AOSLO), where PSF calibration is infeasible. The algorithm predicts and corrects aberrations across multi-millimeter FOVs, enhances contrast in low signal-to-noise regions, and reveals critical structural details in neuronal and vascular systems that are obscured in raw images. This approach enables high-resolution, large-scale imaging without hardware modifications, expanding the accessibility of advanced microscopy techniques.
- Open Access
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (03) , 1-16
Multimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye
SignificanceOxygen metabolism is important to retinal disease development, but current imaging methods face challenges in resolution, throughput, and depth sectioning to spatially map microvascular oxygen.AimWe aim to develop a multimodal system capable of simultaneous phosphorescence lifetime imaging scanning laser ophthalmoscopy (PLIM-SLO) and visible light optical coherence tomography (VIS-OCT) to capture capillary-level oxygen partial pressure (pO2) and structural volumes in rodents.ApproachC57BL/6 mice were imaged by VIS-OCT with high-definition (10 kHz raster) and Doppler (100 kHz circular) protocols. Phosphorescent probe Oxyphor 2P was retro-orbitally injected to enable intravascular PLIM-SLO imaging (200 μs pixel dwell time), and a tunable lens was used to adjust the focal depth. The extracted phosphorescence lifetimes were used for pO2 calculation. Simultaneous imaging utilized a shared imaging path and synchronized data collection.ResultsVIS-OCT images revealed detailed anatomy and Doppler shifts, and PLIM-SLO provided capillary pO2 at multiple depths. A hemoglobin oxygen dissociation curve related retinal arterial pO2 to systemic oxygen saturation as inhaled oxygen was varied. Registered simultaneous images were captured, and pO2 was empirically adjusted for the combined excitation.ConclusionDetailed anatomical structures and capillary pO2 levels can be simultaneously imaged, providing a useful tool to study oxygen metabolism in rodent disease models.
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (03) , 1-16
Open AccessMultimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye
SignificanceOxygen metabolism is important to retinal disease development, but current imaging methods face challenges in resolution, throughput, and depth sectioning to spatially map microvascular oxygen.AimWe aim to develop a multimodal system capable of simultaneous phosphorescence lifetime imaging scanning laser ophthalmoscopy (PLIM-SLO) and visible light optical coherence tomography (VIS-OCT) to capture capillary-level oxygen partial pressure (pO2) and structural volumes in rodents.ApproachC57BL/6 mice were imaged by VIS-OCT with high-definition (10 kHz raster) and Doppler (100 kHz circular) protocols. Phosphorescent probe Oxyphor 2P was retro-orbitally injected to enable intravascular PLIM-SLO imaging (200 μs pixel dwell time), and a tunable lens was used to adjust the focal depth. The extracted phosphorescence lifetimes were used for pO2 calculation. Simultaneous imaging utilized a shared imaging path and synchronized data collection.ResultsVIS-OCT images revealed detailed anatomy and Doppler shifts, and PLIM-SLO provided capillary pO2 at multiple depths. A hemoglobin oxygen dissociation curve related retinal arterial pO2 to systemic oxygen saturation as inhaled oxygen was varied. Registered simultaneous images were captured, and pO2 was empirically adjusted for the combined excitation.ConclusionDetailed anatomical structures and capillary pO2 levels can be simultaneously imaged, providing a useful tool to study oxygen metabolism in rodent disease models.
- Open Access
Multimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye
Significance: Oxygen metabolism is important to retinal disease development, but current imaging methods face challenges in resolution, throughput, and depth sectioning to spatially map microvascular oxygen. Aim: To develop a multimodal system capable of simultaneous phosphorescence lifetime imaging scanning laser ophthalmoscopy (PLIM-SLO) and visible light optical coherence tomography (VIS-OCT) to capture capillary-level oxygen partial pressure (pO 2 ) and structural volumes in rodents. Approach: C57BL/6 mice were imaged by VIS-OCT with high-definition (10 kHz raster) and Doppler (100 kHz circular) protocols. Phosphorescent probe Oxyphor 2P was retro-orbitally injected to enable intravascular PLIM-SLO imaging (200 µs pixel dwell time), while a tunable lens was used to adjust the focal depth. The extracted phosphorescence lifetimes were used for pO 2 calculation. Simultaneous imaging utilized a shared imaging path and synchronized data collection. Results: VIS-OCT images revealed detailed anatomy and Doppler shifts, while PLIM-SLO provided capillary pO 2 at multiple depths. A hemoglobin oxygen dissociation curve related retinal arterial pO 2 to systemic oxygen saturation as inhaled oxygen was varied. Registered simultaneous images were captured and pO 2 was empirically adjusted for the combined excitation. Conclusions: Detailed anatomical structures and capillary pO 2 levels can be simultaneously imaged, providing a useful tool to study oxygen metabolism in rodent disease models.
Open AccessMultimodal retinal imaging by visible light optical coherence tomography and phosphorescence lifetime ophthalmoscopy in the mouse eye
Significance: Oxygen metabolism is important to retinal disease development, but current imaging methods face challenges in resolution, throughput, and depth sectioning to spatially map microvascular oxygen. Aim: To develop a multimodal system capable of simultaneous phosphorescence lifetime imaging scanning laser ophthalmoscopy (PLIM-SLO) and visible light optical coherence tomography (VIS-OCT) to capture capillary-level oxygen partial pressure (pO 2 ) and structural volumes in rodents. Approach: C57BL/6 mice were imaged by VIS-OCT with high-definition (10 kHz raster) and Doppler (100 kHz circular) protocols. Phosphorescent probe Oxyphor 2P was retro-orbitally injected to enable intravascular PLIM-SLO imaging (200 µs pixel dwell time), while a tunable lens was used to adjust the focal depth. The extracted phosphorescence lifetimes were used for pO 2 calculation. Simultaneous imaging utilized a shared imaging path and synchronized data collection. Results: VIS-OCT images revealed detailed anatomy and Doppler shifts, while PLIM-SLO provided capillary pO 2 at multiple depths. A hemoglobin oxygen dissociation curve related retinal arterial pO 2 to systemic oxygen saturation as inhaled oxygen was varied. Registered simultaneous images were captured and pO 2 was empirically adjusted for the combined excitation. Conclusions: Detailed anatomical structures and capillary pO 2 levels can be simultaneously imaged, providing a useful tool to study oxygen metabolism in rodent disease models.
- Open Access
- 4 October 2022
- Published by JMIR Publications Inc. in JMIR Bioinformatics and Biotechnology
- Vol. 3 (1) , e36660
Multiple-Inputs Convolutional Neural Network for COVID-19 Classification and Critical Region Screening From Chest X-ray Radiographs: Model Development and Performance Evaluation
Background: The COVID-19 pandemic is becoming one of the largest, unprecedented health crises, and chest X-ray radiography (CXR) plays a vital role in diagnosing COVID-19. However, extracting and finding useful image features from CXRs demand a heavy workload for radiologists. Objective: The aim of this study was to design a novel multiple-inputs (MI) convolutional neural network (CNN) for the classification of COVID-19 and extraction of critical regions from CXRs. We also investigated the effect of the number of inputs on the performance of our new MI-CNN model. Methods: A total of 6205 CXR images (including 3021 COVID-19 CXRs and 3184 normal CXRs) were used to test our MI-CNN models. CXRs could be evenly segmented into different numbers (2, 4, and 16) of individual regions. Each region could individually serve as one of the MI-CNN inputs. The CNN features of these MI-CNN inputs would then be fused for COVID-19 classification. More importantly, the contributions of each CXR region could be evaluated through assessing the number of images that were accurately classified by their corresponding regions in the testing data sets. Results: In both the whole-image and left- and right-lung region of interest (LR-ROI) data sets, MI-CNNs demonstrated good efficiency for COVID-19 classification. In particular, MI-CNNs with more inputs (2-, 4-, and 16-input MI-CNNs) had better efficiency in recognizing COVID-19 CXRs than the 1-input CNN. Compared to the whole-image data sets, the efficiency of LR-ROI data sets showed approximately 4% lower accuracy, sensitivity, specificity, and precision (over 91%). In considering the contributions of each region, one of the possible reasons for this reduced performance was that nonlung regions (eg, region 16) provided false-positive contributions to COVID-19 classification. The MI-CNN with the LR-ROI data set could provide a more accurate evaluation of the contribution of each region and COVID-19 classification. Additionally, the right-lung regions had higher contributions to the classification of COVID-19 CXRs, whereas the left-lung regions had higher contributions to identifying normal CXRs. Conclusions: Overall, MI-CNNs could achieve higher accuracy with an increasing number of inputs (eg, 16-input MI-CNN). This approach could assist radiologists in identifying COVID-19 CXRs and in screening the critical regions related to COVID-19 classifications.
- 4 October 2022
- Published by JMIR Publications Inc. in JMIR Bioinformatics and Biotechnology
- Vol. 3 (1) , e36660
Open AccessMultiple-Inputs Convolutional Neural Network for COVID-19 Classification and Critical Region Screening From Chest X-ray Radiographs: Model Development and Performance Evaluation
Background: The COVID-19 pandemic is becoming one of the largest, unprecedented health crises, and chest X-ray radiography (CXR) plays a vital role in diagnosing COVID-19. However, extracting and finding useful image features from CXRs demand a heavy workload for radiologists. Objective: The aim of this study was to design a novel multiple-inputs (MI) convolutional neural network (CNN) for the classification of COVID-19 and extraction of critical regions from CXRs. We also investigated the effect of the number of inputs on the performance of our new MI-CNN model. Methods: A total of 6205 CXR images (including 3021 COVID-19 CXRs and 3184 normal CXRs) were used to test our MI-CNN models. CXRs could be evenly segmented into different numbers (2, 4, and 16) of individual regions. Each region could individually serve as one of the MI-CNN inputs. The CNN features of these MI-CNN inputs would then be fused for COVID-19 classification. More importantly, the contributions of each CXR region could be evaluated through assessing the number of images that were accurately classified by their corresponding regions in the testing data sets. Results: In both the whole-image and left- and right-lung region of interest (LR-ROI) data sets, MI-CNNs demonstrated good efficiency for COVID-19 classification. In particular, MI-CNNs with more inputs (2-, 4-, and 16-input MI-CNNs) had better efficiency in recognizing COVID-19 CXRs than the 1-input CNN. Compared to the whole-image data sets, the efficiency of LR-ROI data sets showed approximately 4% lower accuracy, sensitivity, specificity, and precision (over 91%). In considering the contributions of each region, one of the possible reasons for this reduced performance was that nonlung regions (eg, region 16) provided false-positive contributions to COVID-19 classification. The MI-CNN with the LR-ROI data set could provide a more accurate evaluation of the contribution of each region and COVID-19 classification. Additionally, the right-lung regions had higher contributions to the classification of COVID-19 CXRs, whereas the left-lung regions had higher contributions to identifying normal CXRs. Conclusions: Overall, MI-CNNs could achieve higher accuracy with an increasing number of inputs (eg, 16-input MI-CNN). This approach could assist radiologists in identifying COVID-19 CXRs and in screening the critical regions related to COVID-19 classifications.
- Open Access
- 10 June 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (06) , 066001-15
Mouthwash as a non-invasive method of indocyanine green delivery for near-infrared fluorescence dental imaging
Significance: X-ray imaging serves as the mainstream imaging in dentistry, but it involves risk of ionizing radiation. Aim: This study presents the feasibility of indocyanine green-assisted near-infrared fluorescence (ICG-NIRF) dental imaging with 785-nm NIR laser in the first (ICG-NIRF-I: 700 to 1000 nm) and second (ICG-NIRF-II: 1000 to 1700 nm) NIR wavelengths. Approach: Sprague Dawley rats with different postnatal days were used as animal models. ICG, as a fluorescence agent, was delivered to dental structures by subcutaneous injection (SC) and oral administration (OA). Results: For SC method, erupted and unerupted molars could be observed from ICG-NIRF images at a short imaging time (<1 min). ICG-NIRF-II could achieve a better image contrast in unerupted molars at 24 h after ICG injection. The OA could serve as a non-invasive method for ICG delivery; it could also cause the glow-in-dark effect in unerupted molars. For erupted molars, OA can be considered as mouthwash and exhibits outstanding performance for delivery of ICG dye; erupted molar structures could be observed at a short imaging time (<1 min) and low ICG dose (0.05 mg / kg). Conclusions: Overall, ICG-NIRF with mouthwash could perform in-vivo dental imaging in two NIR wavelengths at a short time and low ICG dose.
- 10 June 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (06) , 066001-15
Open AccessMouthwash as a non-invasive method of indocyanine green delivery for near-infrared fluorescence dental imaging
Significance: X-ray imaging serves as the mainstream imaging in dentistry, but it involves risk of ionizing radiation. Aim: This study presents the feasibility of indocyanine green-assisted near-infrared fluorescence (ICG-NIRF) dental imaging with 785-nm NIR laser in the first (ICG-NIRF-I: 700 to 1000 nm) and second (ICG-NIRF-II: 1000 to 1700 nm) NIR wavelengths. Approach: Sprague Dawley rats with different postnatal days were used as animal models. ICG, as a fluorescence agent, was delivered to dental structures by subcutaneous injection (SC) and oral administration (OA). Results: For SC method, erupted and unerupted molars could be observed from ICG-NIRF images at a short imaging time (<1 min). ICG-NIRF-II could achieve a better image contrast in unerupted molars at 24 h after ICG injection. The OA could serve as a non-invasive method for ICG delivery; it could also cause the glow-in-dark effect in unerupted molars. For erupted molars, OA can be considered as mouthwash and exhibits outstanding performance for delivery of ICG dye; erupted molar structures could be observed at a short imaging time (<1 min) and low ICG dose (0.05 mg / kg). Conclusions: Overall, ICG-NIRF with mouthwash could perform in-vivo dental imaging in two NIR wavelengths at a short time and low ICG dose.
- Open Access
- 17 January 2022
- Published by Springer Nature in BMC Pediatrics
- Vol. 22 (1) , 1-4
Paediatric lung injury due to accidental ingestion of meperfluthrin: a case report
Background: It is common for children to accidentally ingest chemical drugs with different degrees of toxicity. Meperfluthrin is a highly effective and easy-to-use pyrethroid pesticide with low toxicity. It is widely used in electric mosquito coils. This type of electric mosquito coil is used in daily life, which increases the chance of exposure among children and, consequently, may lead to accidental ingestion. There are only few reports of meperfluthrin poisoning causing lung injury in children. We report a rare clinical case of lung injury wherein a child ingested meperfluthrin orally. Case presentation: We report the case of a 1-year-old boy who accidentally swallowed an electric mosquito coil containing meperfluthrin and developed cough and fever. The patient’s parents observed him swallowing the electric mosquito coil (Qiangshou®). Although he was stopped, the child had already swallowed approximately 10 ml of the liquid. According to the instructions, it contained 9 mg/ml of meperfluthrin, thus, it was assumed that he ingested meperfluthrin at a dose of approximately 90 mg. Computed tomography (CT) of his lungs showed uneven brightness in both lungs with multiple spots, scaly shadows, and mesh. Density of the shadows indicated lung parenchymal and interstitial lung disease. Lung tidal function tests indicated obstructive ventilation dysfunction. After evaluation and treatment, his cough drastically reduced, his fever disappeared, and his lung CT findings showed improvement. Therefore, accidental ingestion of meperfluthrin led to acute lung injury in a paediatric patient. Because of prompt treatment, his lung lesions recovered well. Conclusions: Meperfluthrin causes airway mucosal damage and hypersensitivity. Lung CT and lung tidal function measurements can be used to monitor changes in the condition. Presently, there is a lack of specific detoxification drugs for meperfluthrin poisoning. Thus, the focus of treatment is to protect the airway mucosa and reduce inflammatory reactions.
- 17 January 2022
- Published by Springer Nature in BMC Pediatrics
- Vol. 22 (1) , 1-4
Open AccessPaediatric lung injury due to accidental ingestion of meperfluthrin: a case report
Background: It is common for children to accidentally ingest chemical drugs with different degrees of toxicity. Meperfluthrin is a highly effective and easy-to-use pyrethroid pesticide with low toxicity. It is widely used in electric mosquito coils. This type of electric mosquito coil is used in daily life, which increases the chance of exposure among children and, consequently, may lead to accidental ingestion. There are only few reports of meperfluthrin poisoning causing lung injury in children. We report a rare clinical case of lung injury wherein a child ingested meperfluthrin orally. Case presentation: We report the case of a 1-year-old boy who accidentally swallowed an electric mosquito coil containing meperfluthrin and developed cough and fever. The patient’s parents observed him swallowing the electric mosquito coil (Qiangshou®). Although he was stopped, the child had already swallowed approximately 10 ml of the liquid. According to the instructions, it contained 9 mg/ml of meperfluthrin, thus, it was assumed that he ingested meperfluthrin at a dose of approximately 90 mg. Computed tomography (CT) of his lungs showed uneven brightness in both lungs with multiple spots, scaly shadows, and mesh. Density of the shadows indicated lung parenchymal and interstitial lung disease. Lung tidal function tests indicated obstructive ventilation dysfunction. After evaluation and treatment, his cough drastically reduced, his fever disappeared, and his lung CT findings showed improvement. Therefore, accidental ingestion of meperfluthrin led to acute lung injury in a paediatric patient. Because of prompt treatment, his lung lesions recovered well. Conclusions: Meperfluthrin causes airway mucosal damage and hypersensitivity. Lung CT and lung tidal function measurements can be used to monitor changes in the condition. Presently, there is a lack of specific detoxification drugs for meperfluthrin poisoning. Thus, the focus of treatment is to protect the airway mucosa and reduce inflammatory reactions.
- 1 December 2021
- Published by Elsevier in Neural Networks
- Vol. 144, 455-464
Detection of pancreatic cancer by convolutional-neural-network-assisted spontaneous Raman spectroscopy with critical feature visualization
- 1 December 2021
- Published by Elsevier in Neural Networks
- Vol. 144, 455-464
Detection of pancreatic cancer by convolutional-neural-network-assisted spontaneous Raman spectroscopy with critical feature visualization
- Open Access
- 17 November 2021
- Published by American Association for the Advancement of Science (AAAS) in Cancer Communications
- Vol. 41 (12) , 1431-1434
Detection of pancreatic cancer by indocyanine green‐assisted fluorescence imaging in the first and second near‐infrared windows
Click on the article title to read more.
- 17 November 2021
- Published by American Association for the Advancement of Science (AAAS) in Cancer Communications
- Vol. 41 (12) , 1431-1434
Open AccessDetection of pancreatic cancer by indocyanine green‐assisted fluorescence imaging in the first and second near‐infrared windows
Click on the article title to read more.
- 1 February 2021
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 64
An optimized JPEG-XT-based algorithm for the lossy and lossless compression of 16-bit depth medical image
- 1 February 2021
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 64
An optimized JPEG-XT-based algorithm for the lossy and lossless compression of 16-bit depth medical image
- 13 May 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (4) , 045009
Improvement of cell deposition by self-absorbent capability of freeze-dried 3D-bioprinted scaffolds derived from cellulose material-alginate hydrogels
Cell-laden printing is the most commonly used approach in 3D bioprinting. One of the major drawbacks of cell-laden printing is that cell viability is highly affected by the extrusion pressure and shear force in the printing process. We present a new cell-deposition method by using the superabsorbent capability of 3D printed scaffolds with four ink formations: 20:10 nanocrystal/alginate (NCA 20/10), 20:10 nanofiber/alginate (NFA 20/10), 20:02 nanocrystal/alginate (NCA 20/02) and 20:02 nanofiber/alginate (NFA 20/02). Limited pores were observed from the surface of inherent NCA and NFA scaffolds, which may limit the numbers of cells to enter into the scaffolds. Therefore, we designed a dual-porous (DP) structure to connect the inherent pores (IPs) to the scaffold surface. Due to these porous structures, NCA and NFA scaffolds exhibit an excellent capability to absorb cell suspension, which may be used for depositing cells to 3D-printed scaffolds, namely self-absorbent (SA) deposition. Compared to the conventional top-loading (TL) method, the SA method had more uniform cell distributions in the entire 3D-printed scaffolds and higher efficiency of cell deposition. For the TL method, DP scaffold exhibited a more uniform cell distribution, which may provide a better microenvironment for the cells in comparison to the IP scaffold. For both cell loading methods, a rapid increase of cell number was observed in the first 4 days of culture in the 3D-printed NCA and NFA structures. NFA 20/02 exhibits the best cell viability compared to the other three inks. In conclusion, the SA method may serve as a new approach for loading cells in cell-free 3D-bioprinting, and DP design could improve the efficiency of the cell deposition.
- 13 May 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (4) , 045009
Improvement of cell deposition by self-absorbent capability of freeze-dried 3D-bioprinted scaffolds derived from cellulose material-alginate hydrogels
Cell-laden printing is the most commonly used approach in 3D bioprinting. One of the major drawbacks of cell-laden printing is that cell viability is highly affected by the extrusion pressure and shear force in the printing process. We present a new cell-deposition method by using the superabsorbent capability of 3D printed scaffolds with four ink formations: 20:10 nanocrystal/alginate (NCA 20/10), 20:10 nanofiber/alginate (NFA 20/10), 20:02 nanocrystal/alginate (NCA 20/02) and 20:02 nanofiber/alginate (NFA 20/02). Limited pores were observed from the surface of inherent NCA and NFA scaffolds, which may limit the numbers of cells to enter into the scaffolds. Therefore, we designed a dual-porous (DP) structure to connect the inherent pores (IPs) to the scaffold surface. Due to these porous structures, NCA and NFA scaffolds exhibit an excellent capability to absorb cell suspension, which may be used for depositing cells to 3D-printed scaffolds, namely self-absorbent (SA) deposition. Compared to the conventional top-loading (TL) method, the SA method had more uniform cell distributions in the entire 3D-printed scaffolds and higher efficiency of cell deposition. For the TL method, DP scaffold exhibited a more uniform cell distribution, which may provide a better microenvironment for the cells in comparison to the IP scaffold. For both cell loading methods, a rapid increase of cell number was observed in the first 4 days of culture in the 3D-printed NCA and NFA structures. NFA 20/02 exhibits the best cell viability compared to the other three inks. In conclusion, the SA method may serve as a new approach for loading cells in cell-free 3D-bioprinting, and DP design could improve the efficiency of the cell deposition.