Prajwal P. Ravinder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Prajwal P. Ravinder has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ali Talyshinskii
Saint Petersburg State University
1 shared publication - Belthangady Monu Zeeshan Hameed
Department of Urology, Father Muller Medical College, Mangalore, India
1 shared publication - Bhaskar Kumar Somani
University Hospital Southampton NHS Trust, UK
1 shared publication - Bhavan Prasad Rai
Department of Urology, Freeman Hospital, The Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
1 shared publication - Milap Shah
TRUE (International Training and Research in Uro-Oncology and Endourology) Group, Manipal 576104, Karnataka, India
1 shared publication - Nithesh Naik
Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India
1 shared publication
Latest Publications
- Open Access
Catalyzing Precision Medicine: Artificial Intelligence Advancements in Prostate Cancer Diagnosis and Management
Background: The aim was to analyze the current state of deep learning (DL)-based prostate cancer (PCa) diagnosis with a focus on magnetic resonance (MR) prostate reconstruction; PCa detection/stratification/reconstruction; positron emission tomography/computed tomography (PET/CT); androgen deprivation therapy (ADT); prostate biopsy; associated challenges and their clinical implications. Methods: A search of the PubMed database was conducted based on the inclusion and exclusion criteria for the use of DL methods within the abovementioned areas. Results: A total of 784 articles were found, of which, 64 were included. Reconstruction of the prostate, the detection and stratification of prostate cancer, the reconstruction of prostate cancer, and diagnosis on PET/CT, ADT, and biopsy were analyzed in 21, 22, 6, 7, 2, and 6 studies, respectively. Among studies describing DL use for MR-based purposes, datasets with magnetic field power of 3 T, 1.5 T, and 3/1.5 T were used in 18/19/5, 0/1/0, and 3/2/1 studies, respectively, of 6/7 studies analyzing DL for PET/CT diagnosis which used data from a single institution. Among the radiotracers, [68Ga]Ga-PSMA-11, [18F]DCFPyl, and [18F]PSMA-1007 were used in 5, 1, and 1 study, respectively. Only two studies that analyzed DL in the context of DT met the inclusion criteria. Both were performed with a single-institution dataset with only manual labeling of training data. Three studies, each analyzing DL for prostate biopsy, were performed with single- and multi-institutional datasets. TeUS, TRUS, and MRI were used as input modalities in two, three, and one study, respectively. Conclusion: DL models in prostate cancer diagnosis show promise but are not yet ready for clinical use due to variability in methods, labels, and evaluation criteria. Conducting additional research while acknowledging all the limitations outlined is crucial for reinforcing the utility and effectiveness of DL-based models in clinical settings.
Open AccessCatalyzing Precision Medicine: Artificial Intelligence Advancements in Prostate Cancer Diagnosis and Management
Background: The aim was to analyze the current state of deep learning (DL)-based prostate cancer (PCa) diagnosis with a focus on magnetic resonance (MR) prostate reconstruction; PCa detection/stratification/reconstruction; positron emission tomography/computed tomography (PET/CT); androgen deprivation therapy (ADT); prostate biopsy; associated challenges and their clinical implications. Methods: A search of the PubMed database was conducted based on the inclusion and exclusion criteria for the use of DL methods within the abovementioned areas. Results: A total of 784 articles were found, of which, 64 were included. Reconstruction of the prostate, the detection and stratification of prostate cancer, the reconstruction of prostate cancer, and diagnosis on PET/CT, ADT, and biopsy were analyzed in 21, 22, 6, 7, 2, and 6 studies, respectively. Among studies describing DL use for MR-based purposes, datasets with magnetic field power of 3 T, 1.5 T, and 3/1.5 T were used in 18/19/5, 0/1/0, and 3/2/1 studies, respectively, of 6/7 studies analyzing DL for PET/CT diagnosis which used data from a single institution. Among the radiotracers, [68Ga]Ga-PSMA-11, [18F]DCFPyl, and [18F]PSMA-1007 were used in 5, 1, and 1 study, respectively. Only two studies that analyzed DL in the context of DT met the inclusion criteria. Both were performed with a single-institution dataset with only manual labeling of training data. Three studies, each analyzing DL for prostate biopsy, were performed with single- and multi-institutional datasets. TeUS, TRUS, and MRI were used as input modalities in two, three, and one study, respectively. Conclusion: DL models in prostate cancer diagnosis show promise but are not yet ready for clinical use due to variability in methods, labels, and evaluation criteria. Conducting additional research while acknowledging all the limitations outlined is crucial for reinforcing the utility and effectiveness of DL-based models in clinical settings.