Haibin Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haibin Lin has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Feng Zheng
Putian Univ, Affiliated Hosp, Dept Orthoped, 999 Dongzhen Dong Rd, Licheng Dist, Putian, Peoples R China
1 shared publication- Feng Zheng
Department of Electrical Engineering, School of Electrical and Mechanical Engineering, Xidian University, Xian, China
1 shared publication Guodong Zhang
Putian Univ, Affiliated Hosp, Dept Orthoped, 999 Dongzhen Dong Rd, Licheng Dist, Putian, Peoples R China
1 shared publication- Guodong Zhang
State Grid Fujian Electric Power Co., Ltd.,Changle District Power Supply Company,Fuzhou City,China
1 shared publication - Wenhua Huang
Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, Guangdong Provincial Key Laboratory of Medical Biomechanics, National Key Discipline of Human Anatomy, School of Basic Medical Sciences, Southern Medical University, Guangzhou, China
1 shared publication - Wenhua Huang
Southern Med Univ, Sch Basic Med Sci, Natl Key Discipline Human Anat, 1838 Guangzhou Rd North, Guangzhou, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 1 November 2020
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 8 (22) , 1512
An experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
Background: In this experimental study, we evaluated the use of digital 3D navigation printing in minimizing complications arising from sacroiliac screw misplacement. Methods: A total of 13 adult pelvic specimens were studied using 3D navigation printing. Mimics software was used for preoperative planning and for obtaining sacrum median sagittal resection and long axis resection of the S1 pedicle center by 3D segmentation. The ideal screw path had its origin at the post-median part of the auricular surface of the sacroiliac joint, the midpoint at the mid-position of the lateral recess and outlet of the anterior sacral foramina; and the endpoint at the S1 sagittal resection. A sacroiliac screw fixed the pelvic specimens with the assistance of the navigation module. The distance between the start point (ilium surface) and endpoint (sacral median sagittal resection) of the screw path was measured after the pre- and postoperative 3D pelvis module was 3D-registered according to the standard precision range. The origin/endpoint qualified rates of the postoperative (n/26) and preoperative (26/26) screw paths were analyzed by the chi-square test. Results: No screw misplacement occurred in the screw paths of any of the 13 pelvic specimens. The mean distance between the preoperative and postoperative origin of the screw path was 1.5415±0.6806 mm, and the mean distance between the preoperative and postoperative endpoint was 2.2809±0.4855 mm. The qualified rate of origin was 23/26 when the precision grade was 2.4 mm (P>0.05, χ2=1.41), while the qualified rate of endpoint was 21/26 when the precision grade was 2.7 mm (P>0.05, χ2=3.54). Conclusions: In this experimental study, using a 3D printing navigation module helped attain an accurate and safe sacroiliac screw implantation.
- 1 November 2020
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 8 (22) , 1512
Open AccessAn experimental study on the safe placement of sacroiliac screws using a 3D printing navigation module
Background: In this experimental study, we evaluated the use of digital 3D navigation printing in minimizing complications arising from sacroiliac screw misplacement. Methods: A total of 13 adult pelvic specimens were studied using 3D navigation printing. Mimics software was used for preoperative planning and for obtaining sacrum median sagittal resection and long axis resection of the S1 pedicle center by 3D segmentation. The ideal screw path had its origin at the post-median part of the auricular surface of the sacroiliac joint, the midpoint at the mid-position of the lateral recess and outlet of the anterior sacral foramina; and the endpoint at the S1 sagittal resection. A sacroiliac screw fixed the pelvic specimens with the assistance of the navigation module. The distance between the start point (ilium surface) and endpoint (sacral median sagittal resection) of the screw path was measured after the pre- and postoperative 3D pelvis module was 3D-registered according to the standard precision range. The origin/endpoint qualified rates of the postoperative (n/26) and preoperative (26/26) screw paths were analyzed by the chi-square test. Results: No screw misplacement occurred in the screw paths of any of the 13 pelvic specimens. The mean distance between the preoperative and postoperative origin of the screw path was 1.5415±0.6806 mm, and the mean distance between the preoperative and postoperative endpoint was 2.2809±0.4855 mm. The qualified rate of origin was 23/26 when the precision grade was 2.4 mm (P>0.05, χ2=1.41), while the qualified rate of endpoint was 21/26 when the precision grade was 2.7 mm (P>0.05, χ2=3.54). Conclusions: In this experimental study, using a 3D printing navigation module helped attain an accurate and safe sacroiliac screw implantation.
- Open Access
- 1 August 2020
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 8 (16) , 1012
Design, application, and evaluation of a novel method for determining optimal trajectory of thoracic pedicle screws
Background: This is an experimental study performed on 15 adult cadavers. In this cadaveric study, we designed and evaluated a novel methodology for determining the optimal trajectory for the placement of thoracic pedicle screws. The accuracy of thoracic pedicle screw placement is critical to the spinal surgery. The concept, implement method, and significance of the optimal thoracic pedicle trajectory have not been reported. Methods: The experimental study was performed on 15 adult cadavers. The Mimics software was used to design optimal trajectory through the pedicle central axis. Using three-dimensional (3D) printing, a navigation module with a locating facet and a stabilizing facet was developed. The thoracic pedicle screws were inserted with the help of the navigation module. The three-dimensional coordinates for the entry and the exit points of the screws were compared between the planned trajectories and the postoperative trajectories. The differences in coordinates were analyzed to evaluate the precision of the screw placement. Results: The trajectories through the pedicle central axis showed an excellent symmetry between the single segments and for all thoracic vertebrae. Out of a total of 358 screws that were inserted, 15 (4.2%) screws breached the pedicle cortex with a breach distance of 0.05). Conclusions: The optimal trajectory was obtained through the pedicle central axis, which significantly reduced the risk of cortex breach. A high degree of precision was obtained for the entry and the exit points of the screws when the postoperative trajectory was compared with the designed trajectory.
- 1 August 2020
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 8 (16) , 1012
Open AccessDesign, application, and evaluation of a novel method for determining optimal trajectory of thoracic pedicle screws
Background: This is an experimental study performed on 15 adult cadavers. In this cadaveric study, we designed and evaluated a novel methodology for determining the optimal trajectory for the placement of thoracic pedicle screws. The accuracy of thoracic pedicle screw placement is critical to the spinal surgery. The concept, implement method, and significance of the optimal thoracic pedicle trajectory have not been reported. Methods: The experimental study was performed on 15 adult cadavers. The Mimics software was used to design optimal trajectory through the pedicle central axis. Using three-dimensional (3D) printing, a navigation module with a locating facet and a stabilizing facet was developed. The thoracic pedicle screws were inserted with the help of the navigation module. The three-dimensional coordinates for the entry and the exit points of the screws were compared between the planned trajectories and the postoperative trajectories. The differences in coordinates were analyzed to evaluate the precision of the screw placement. Results: The trajectories through the pedicle central axis showed an excellent symmetry between the single segments and for all thoracic vertebrae. Out of a total of 358 screws that were inserted, 15 (4.2%) screws breached the pedicle cortex with a breach distance of 0.05). Conclusions: The optimal trajectory was obtained through the pedicle central axis, which significantly reduced the risk of cortex breach. A high degree of precision was obtained for the entry and the exit points of the screws when the postoperative trajectory was compared with the designed trajectory.