Chunyu Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chunyu Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bo Ma
Single-Cell Center, Key Laboratory of Photoelectric Conversion and Utilization of Solar Energy, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao, Shandong, China; Shandong Energy Institute, Qingdao, Shandong, China; Qingdao New Energy Shandong Laboratory, Qingdao, Shandong, China; University of Chinese Academy of Sciences, Beijing, China
4 shared publications Jian Xu
Single‐Cell Center CAS Key Laboratory of Biofuels and Shandong Key Laboratory of Energy Genetics Qingdao Institute of Bioenergy and Bioprocess Technology Chinese Academy of Sciences Qingdao Shandong 266071 China
3 shared publicationsXixian Wang
Single‐Cell Center CAS Key Laboratory of Biofuels and Shandong Key Laboratory of Energy Genetics Qingdao Institute of Bioenergy and Bioprocess Technology Chinese Academy of Sciences Qingdao Shandong 266071 China
2 shared publicationsYanhai Gong
Chinese Acad Sci, Single Cell Ctr, CAS Key Lab Biofuels, Qingdao, Shandong, Peoples R China
2 shared publicationsFei Wu
Chinese Acad Sci, Single Cell Ctr, CAS Key Lab Biofuels, Qingdao, Shandong, Peoples R China
1 shared publication- Jian Xu
Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Science
1 shared publication
Latest Publications
- 29 January 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 406
A microfluidics-free centrifugally-driven nano-liquid pipetting system (CNPS) for single-cell whole genome amplification
- 29 January 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 406
A microfluidics-free centrifugally-driven nano-liquid pipetting system (CNPS) for single-cell whole genome amplification
Integrated Addressable Dynamic Droplet Array (aDDA) as Sub‐Nanoliter Reactors for High‐Coverage Genome Sequencing of Single Yeast Cells
An addressable dynamic droplet array (aDDA) is presented that combines the advantages of static droplet arrays and continuous‐flow droplet platforms. Modular fabrication is employed to create a self‐contained integrated aDDA. All the sample preparation steps, including single‐cell isolation, cell lysis, amplification, and product retrieval, are performed in sequence within a sub‐nanoliter (≈300 pL) droplet. Sequencing‐based validation suggests that aDDA reduces the amplification bias of multiple displacement amplification (MDA) and elevates the percentage of one‐yeast‐cell genome recovery to 91%, as compared to the average of 26% using conventional, 20 µL volume MDA reactions. Thus, aDDA is a valuable addition to the toolbox for high‐genome‐coverage sequencing of single microbial cells.
Integrated Addressable Dynamic Droplet Array (aDDA) as Sub‐Nanoliter Reactors for High‐Coverage Genome Sequencing of Single Yeast Cells
An addressable dynamic droplet array (aDDA) is presented that combines the advantages of static droplet arrays and continuous‐flow droplet platforms. Modular fabrication is employed to create a self‐contained integrated aDDA. All the sample preparation steps, including single‐cell isolation, cell lysis, amplification, and product retrieval, are performed in sequence within a sub‐nanoliter (≈300 pL) droplet. Sequencing‐based validation suggests that aDDA reduces the amplification bias of multiple displacement amplification (MDA) and elevates the percentage of one‐yeast‐cell genome recovery to 91%, as compared to the average of 26% using conventional, 20 µL volume MDA reactions. Thus, aDDA is a valuable addition to the toolbox for high‐genome‐coverage sequencing of single microbial cells.
- 28 August 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (21) , 6813-6820
One-step liquid molding based modular microfluidic circuits
Modular concepts open a new way to create customized integrated microfluidic devices for the changing needs of users. However, easy-to-follow modular construction at the micro-scale remains a crucial challenge. Here, we present a one-step liquid molding based modular method. Liquid molding was coupled with standard SU-8 lithography to fabricate the connection adapters and the intricate micro-flow networks of modules. The connection adapter in each of the modules with three-dimensional topographic structures bridges the gap between the macroscopic world and the microfluidic network. Analogous to electronic circuits, individual functional components were assembled together via the standard fused silica capillary tubing in series or parallel, forming a leak-free integrated whole. The modular microfluidic circuits were further applied to pathogenic bacteria detection and parallel droplet generation. Via these applications, we demonstrated that modular circuits can be easily assembled and disassembled, thus enabling easy reconfiguration. Additionally, the ability to incorporate components made from different materials was exhibited.
- 28 August 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (21) , 6813-6820
One-step liquid molding based modular microfluidic circuits
Modular concepts open a new way to create customized integrated microfluidic devices for the changing needs of users. However, easy-to-follow modular construction at the micro-scale remains a crucial challenge. Here, we present a one-step liquid molding based modular method. Liquid molding was coupled with standard SU-8 lithography to fabricate the connection adapters and the intricate micro-flow networks of modules. The connection adapter in each of the modules with three-dimensional topographic structures bridges the gap between the macroscopic world and the microfluidic network. Analogous to electronic circuits, individual functional components were assembled together via the standard fused silica capillary tubing in series or parallel, forming a leak-free integrated whole. The modular microfluidic circuits were further applied to pathogenic bacteria detection and parallel droplet generation. Via these applications, we demonstrated that modular circuits can be easily assembled and disassembled, thus enabling easy reconfiguration. Additionally, the ability to incorporate components made from different materials was exhibited.
- 7 October 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 18 (5) , 1067-1073
A self-powered microfluidic monodispersed droplet generator with capability of multi-sample introduction
- 7 October 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 18 (5) , 1067-1073
A self-powered microfluidic monodispersed droplet generator with capability of multi-sample introduction