FSFrancesca Stufano

Francesca Stufano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Francesca Stufano has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Flora Peyvandi

    Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Angelo Bianchi Bonomi Hemophilia and Thrombosis Center, Milan, Italy

    2 shared publications
  • A. S. Lawrie

    Haemostasis Research Unit Department of Haematology University College London London UK

    1 shared publication
  • Alberto Tedeschi

    Allergy and Clinical Immunology Outpatient Clinic, Milan, Italy

    1 shared publication
  • C. Berbenni

    Angelo Bianchi Bonomi Hemophilia and Thrombosis Center Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico Milan Italy

    1 shared publication
  • Federica Depetri

    Medicina Interna, Dipartimento di Fisiopatologia Medico-Chirurgica e dei Trapianti, Università degli Studi di Milano, Ospedale Maggiore Policlinico, Fondazione IRCCS Ca' Granda, Via Pace, 9, 20122, Milan, Italy.

    1 shared publication
  • Franca Franchi

    Angelo Bianchi Bonomi Hemophilia and Thrombosis Center, Department of Pathophysiology and Transplantation, Università degli Studi di Milano, Milan, Italy

    1 shared publication

Latest Publications

  • Open Access

    Salvage therapy with high dose Intravenous Immunoglobulins in acquired Von Willebrand Syndrome and unresponsive severe intestinal bleeding

    by Massimo Cugno, Alberto Tedeschi, Simona Maria Siboni, Francesca Stufano, Federica Depetri, Franca Franchi, Samantha Griffini, Flora Peyvandi

    A 91-year-old woman affected with acquired Von Willebrand (VW) syndrome and intestinal angiodysplasias presented with severe gastrointestinal bleeding (hemoglobin 5 g/dl). Despite replacement therapy with VW factor/factor VIII concentrate qid, bleeding did not stop (eleven packed red blood cell units were transfused over three days). High circulating levels of anti-VW factor immunoglobulin M were documented immunoenzimatically. Heart ultrasound showed abnormalities of the mitral and aortic valves with severe flow alterations. When intravenous immunoglobulins were added to therapy, prompt clinical and laboratory responses occurred: complete cessation of bleeding, raise in hemoglobin, VW factor antigen, VW ristocetin cofactor and factor VIII levels as well as progressive reduction of the anti-VWF autoantibody levels.


  • A two‐centre comparative evaluation of new automated assays for von Willebrand factor ristocetin cofactor activity and antigen

    by F. Stufano, A. S. Lawrie, S. La Marca, C. Berbenni, L. Baronciani, F. Peyvandi

    Summary: von Willebrand disease (VWD) is caused by a quantitative and/or qualitative deficiency of the von Willebrand factor (VWF). The laboratory diagnosis of VWD is dependent on the measurement of VWF antigen (VWF:Ag) and ristocetin cofactor activity (VWF:RCo). The aim of this study was to undertake a two‐centre evaluation of two new automated VWF:Ag and VWF:RCo assays systems from Instrumentation Laboratory (Bedford, USA). Using the two new analytical systems that operated with different detection principles: immunoturbidimetric (TOP500 analyser) and chemiluminescent (AcuStar analyser), VWF:Ag and VWF:RCo levels were determined in samples from 171 healthy normal subjects, 80 VWD patients (16 type 1, 58 type 2 and 6 type 3) and 7 acquired von Willebrand syndrome patients. With commercial lyophilized normal and pathological plasmas VWF: Ag and VWF:RCo assays performed on both analysers exhibited low levels of inter‐assay imprecision (AcuStar: CV% range 3.3–6.9; TOP500: CV% range 2.6–6.3). Samples from normal healthy subjects (range: VWF:Ag 44.6–173.9 IU dL−1; VWF:RCo 43.1–191.5 IU dL−1) and patients (range: VWF:Ag −1; VWF:RCo −1) showed a good correlation between the two VWF:Ag and VWF:RCo methods (rs = 0.92 and 0.82 respectively), with only a few inconsistent cases among the patients' samples evaluated. The chemiluminescent assays had a lower limit of detection for both VWF:Ag and VWF:RCo compared to immunoturbidimetric tests (0.3 IU dL−1 vs. 2.2 IU dL−1 and 0.5 IU dL−1 vs. 4.4 IU dL−1 respectively). The TOP500 and AcuStar VWF:Ag and VWF:RCo assays were precise and compare well between centres, making these systems suitable for the diagnosis of VWD in non‐specialized and reference laboratories.