Wei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Wang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Dongdong Yang
State Grid Shanxi Electric Power Company Electric Power Science Research Institute, China
2 shared publicationsLin Yan
State Grid Taiyuan Power Supply Company, Taiyuan, China
2 shared publicationsDongxun Wu
Economic and Technical Research Institute of SEPC of SGCC Taiyuan Shanxi People's Republic of China
1 shared publicationFan Hu
State Grid Shanxi Electric Power Research Institute Taiyuan Shanxi People's Republic of China
1 shared publicationFengjie Ma
International Institute of Engineering, Changsha University of Science and Technology, Changsha, China
1 shared publicationGuanliang Li
State Grid Shanxi Electric Power Company Electric Power Science Research Institute, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by IGI Global Scientific Publishing in International Journal of Information Technologies and Systems Approach
- Vol. 18 (1) , 1-20
Low Voltage Distribution Area Topology Identification Based on Voltage Feature and Correlation
The task of obtaining topological information on low-voltage distribution areas has been plagued by issues such as prolonged data absence and delayed updates. To address this issue, this paper proposes a low-voltage distribution area topology identification method based on voltage feature extraction. This method includes two main parts: voltage feature extraction and topology identification. The first-order difference coefficient and peak coefficient were extracted from the collected raw voltage data to construct a dataset of voltage features. Then DPC clustering was used to identify phase relationships, and the Kendall correlation coefficient was used to arrange the membership relationship. Through this process topology identification for low-voltage distribution areas has been achieved. The effects of different clustering methods and different correlation coefficients on topology recognition are compared in the case study. The results show that the proposed method can achieve higher accuracy in topology recognition.
- 1 January 2025
- Published by IGI Global Scientific Publishing in International Journal of Information Technologies and Systems Approach
- Vol. 18 (1) , 1-20
Open AccessLow Voltage Distribution Area Topology Identification Based on Voltage Feature and Correlation
The task of obtaining topological information on low-voltage distribution areas has been plagued by issues such as prolonged data absence and delayed updates. To address this issue, this paper proposes a low-voltage distribution area topology identification method based on voltage feature extraction. This method includes two main parts: voltage feature extraction and topology identification. The first-order difference coefficient and peak coefficient were extracted from the collected raw voltage data to construct a dataset of voltage features. Then DPC clustering was used to identify phase relationships, and the Kendall correlation coefficient was used to arrange the membership relationship. Through this process topology identification for low-voltage distribution areas has been achieved. The effects of different clustering methods and different correlation coefficients on topology recognition are compared in the case study. The results show that the proposed method can achieve higher accuracy in topology recognition.
- Open Access
- 24 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 145118-145129
Polypropylene’s Crystallization Morphology During the Non-Isothermal Crystallization Process and Its Electrical Properties
To understand the mechanism of the effect of the cooling rate of the non-isothermal crystallization process on the crystallization morphology of polypropylene (PP) insulation, and the relationship between the crystallization morphology and DC breakdown performance, this paper researched the crystallization morphology, physicochemical property, polarization current and DC breakdown strength of PP specimens with five cooling rates. As the cooling rate increases, due to the reduction of the diameter and perfection degree of PP spherulites, the density of amorphous regions increases, deep traps are introduced, and the DC breakdown strength is enhanced. The DC breakdown strength of PP specimen with a cooling rate of 170 °C/min is about 2.4 times higher than that of PP specimen with a cooling rate of 10 °C/min. Therefore, by controlling the cooling rates, the crystallization regulation of PP can be realized. That is, by affecting the development process of PP nucleation and spherulites development, resulting in changes in the crystallization morphology, which in turn changes the properties of PP such as glass transition temperature, melting range, and breaking elongation. Finally, the regulation of carrier transport in PP, i.e., insulation properties, is realized, which provides a basis for the improvement of PP insulating materials.
- 24 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 145118-145129
Open AccessPolypropylene’s Crystallization Morphology During the Non-Isothermal Crystallization Process and Its Electrical Properties
To understand the mechanism of the effect of the cooling rate of the non-isothermal crystallization process on the crystallization morphology of polypropylene (PP) insulation, and the relationship between the crystallization morphology and DC breakdown performance, this paper researched the crystallization morphology, physicochemical property, polarization current and DC breakdown strength of PP specimens with five cooling rates. As the cooling rate increases, due to the reduction of the diameter and perfection degree of PP spherulites, the density of amorphous regions increases, deep traps are introduced, and the DC breakdown strength is enhanced. The DC breakdown strength of PP specimen with a cooling rate of 170 °C/min is about 2.4 times higher than that of PP specimen with a cooling rate of 10 °C/min. Therefore, by controlling the cooling rates, the crystallization regulation of PP can be realized. That is, by affecting the development process of PP nucleation and spherulites development, resulting in changes in the crystallization morphology, which in turn changes the properties of PP such as glass transition temperature, melting range, and breaking elongation. Finally, the regulation of carrier transport in PP, i.e., insulation properties, is realized, which provides a basis for the improvement of PP insulating materials.
- Open Access
- 6 February 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1257-1260
Inrush current method of transformer based on wavelet packet and neural network
The transformer is an important equipment of power system; its operation state is directly related to the security and stability of the power system. Aiming at the problem that the differential protection of power transformer has been plagued by inrush current, a recognition method based on wavelet packet and the neural network is proposed. The inrush current and fault current signal are decomposed and reconstructed by using wavelet packet to extract wavelet packet reconstruction coefficients and calculate the energy of each band. These feature vectors are chosen as input values for the neural network. It has been shown by experiments that the inrush current and internal fault current can be accurately identified and the identification method can meet the requirement of the transformer inrush current real‐time identification system.
- 6 February 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1257-1260
Open AccessInrush current method of transformer based on wavelet packet and neural network
The transformer is an important equipment of power system; its operation state is directly related to the security and stability of the power system. Aiming at the problem that the differential protection of power transformer has been plagued by inrush current, a recognition method based on wavelet packet and the neural network is proposed. The inrush current and fault current signal are decomposed and reconstructed by using wavelet packet to extract wavelet packet reconstruction coefficients and calculate the energy of each band. These feature vectors are chosen as input values for the neural network. It has been shown by experiments that the inrush current and internal fault current can be accurately identified and the identification method can meet the requirement of the transformer inrush current real‐time identification system.
- Open Access
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2043-2047
Partial discharge of white noise suppression method based on EEMD and higher order statistics
The insulation deterioration of mining dry‐type transformer is always accompanied with partial discharge (PD). The assessment accuracy of transformer insulation performance is directly affected by the authenticity of the PD signal. Based on the ensemble empirical mode decomposition (EEMD) and combining the principle of higher order statistics, a hybrid method for suppressing white noise in PD signals was proposed. First, the PD signals were decomposed into a number of intrinsic mode function (IMF) components. Then the signal's Gaussian components were detected and removed by kurtosis as gaussianity estimators supplemented by bootstrap techniques. The white noise in the components were suppressed through thresholding and reconstructing each IMF with adaptive thresholds. Finally, the results were reconstructed and return to the original signal. The validity of this method is proved by simulated signals and practical PD signals.
- 1 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2043-2047
Open AccessPartial discharge of white noise suppression method based on EEMD and higher order statistics
The insulation deterioration of mining dry‐type transformer is always accompanied with partial discharge (PD). The assessment accuracy of transformer insulation performance is directly affected by the authenticity of the PD signal. Based on the ensemble empirical mode decomposition (EEMD) and combining the principle of higher order statistics, a hybrid method for suppressing white noise in PD signals was proposed. First, the PD signals were decomposed into a number of intrinsic mode function (IMF) components. Then the signal's Gaussian components were detected and removed by kurtosis as gaussianity estimators supplemented by bootstrap techniques. The white noise in the components were suppressed through thresholding and reconstructing each IMF with adaptive thresholds. Finally, the results were reconstructed and return to the original signal. The validity of this method is proved by simulated signals and practical PD signals.