Manal Alfakhri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Manal Alfakhri has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Ben Lineton
Institute of Sound and Vibration Research, University of Southampton
2 shared publicationsNicole Campbell
King Saud University
2 shared publications- Ali Almutor
School of Medicine, The University of Jordan, Amman 11942, Jordan
1 shared publication - Ben Lineton
Faculty of Engineering and Physical Sciences, University of Southampton 1 , Southampton, SO17 1BJ
1 shared publication Carl Verschuur
Institute of Sound and Vibration Research, University of Southampton
1 shared publication- Carl Verschuur
Institute of Sound and Vibration Research, Faculty of Engineering and Physical Sciences, University of Southampton
1 shared publication
Latest Publications
- Open Access
- 18 November 2026
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 12 (4) , 102
Loss to Diagnostic Follow-Up After Universal Newborn Hearing Screening in Well Infants: A Cohort Study
Loss to follow-up (LTFU) after newborn hearing screening (NHS) is a persistent, internationally documented barrier to diagnosis and intervention. This cohort study evaluated diagnostic follow-up after NHS among well infants at a tertiary hospital in Jordan (February 2024–February 2025) and examined factors associated with initial OAE referral. Well newborns underwent otoacoustic emission (OAE) screening at birth; those who did not pass were scheduled for repeat OAE at 2 weeks and diagnostic auditory brainstem response (ABR) evaluation at 2 months when indicated. Among 1074 screened infants, 100 (9.3%) did not pass initial OAE, and 26 (26.0%) returned for repeat testing (LTFU = 74.0%). Of 57 infants meeting criteria for diagnostic ABR, 3 (5.3%) completed evaluation (LTFU = 94.7%); no tested factor predicted initial OAE referral, and ABR- LTFU predictors could not be analyzed. Most families with incomplete evaluation (72%) could not be reached because contact information recorded at screening was inaccurate or outdated; barriers among families reached included perceived normal hearing, financial constraints, and difficulty accessing the clinic. Although poor diagnostic follow-up is a documented challenge across high-, middle-, and low-income settings, the LTFU observed here (74.0–94.7%) was higher than international averages and comparable to the upper range reported among programs lacking systemic tracking infrastructure, underscoring the absence of a dedicated follow-up and recall system as the primary driver. Establishing centralized data tracking, structured recall procedures, and parental education are essential to closing this gap.
- 18 November 2026
- Published by MDPI AG in International Journal of Neonatal Screening
- Vol. 12 (4) , 102
Open AccessLoss to Diagnostic Follow-Up After Universal Newborn Hearing Screening in Well Infants: A Cohort Study
Loss to follow-up (LTFU) after newborn hearing screening (NHS) is a persistent, internationally documented barrier to diagnosis and intervention. This cohort study evaluated diagnostic follow-up after NHS among well infants at a tertiary hospital in Jordan (February 2024–February 2025) and examined factors associated with initial OAE referral. Well newborns underwent otoacoustic emission (OAE) screening at birth; those who did not pass were scheduled for repeat OAE at 2 weeks and diagnostic auditory brainstem response (ABR) evaluation at 2 months when indicated. Among 1074 screened infants, 100 (9.3%) did not pass initial OAE, and 26 (26.0%) returned for repeat testing (LTFU = 74.0%). Of 57 infants meeting criteria for diagnostic ABR, 3 (5.3%) completed evaluation (LTFU = 94.7%); no tested factor predicted initial OAE referral, and ABR- LTFU predictors could not be analyzed. Most families with incomplete evaluation (72%) could not be reached because contact information recorded at screening was inaccurate or outdated; barriers among families reached included perceived normal hearing, financial constraints, and difficulty accessing the clinic. Although poor diagnostic follow-up is a documented challenge across high-, middle-, and low-income settings, the LTFU observed here (74.0–94.7%) was higher than international averages and comparable to the upper range reported among programs lacking systemic tracking infrastructure, underscoring the absence of a dedicated follow-up and recall system as the primary driver. Establishing centralized data tracking, structured recall procedures, and parental education are essential to closing this gap.
- Open Access
- 23 September 2026
- Published by Taylor & Francis in Cochlear Implants International
- p. 1-14
Integrated bimodal and bilateral cochlear implant users: who performs better, and how do they compare with normal hearing listeners on a ‘real-life’ test battery?
Binaural hearing is important in real-life listening environments, including speech perception in noise, sound localisation, and tracking of moving sounds (Butler, 1986; Feuerstein, 1992; Middlebro...
- 23 September 2026
- Published by Taylor & Francis in Cochlear Implants International
- p. 1-14
Open AccessIntegrated bimodal and bilateral cochlear implant users: who performs better, and how do they compare with normal hearing listeners on a ‘real-life’ test battery?
Binaural hearing is important in real-life listening environments, including speech perception in noise, sound localisation, and tracking of moving sounds (Butler, 1986; Feuerstein, 1992; Middlebro...
- Open Access
- 3 July 2024
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 25 (4) , 260-274
International survey of bimodal hearing and bilateral cochlear implant service provision for adults
As cochlear implant (CI) criteria widen, more candidates with usable residual hearing are being considered for a CI. Unlike children, adults mostly receive only one implant. The aim of this survey was to determine bimodal-hearing and bilateral CI service provision for adults around the world. This survey offers the backdrop against which future clinical practice and service delivery can be considered. CI professionals from across the world were invited to participate in an international multicentre survey. The online questionnaire was circulated to CI professionals in 75 countries. There were 64 respondents, representing 25 countries across five world regions. In this sample, adult CI users most had unilateral CI (74.5%) and only 25.5% were bilateral CI users. Some 54% of unilateral CI users used a hearing aid (HA) in the non-implanted ear. Funding for a second implant or HA was not well supported for adult unilateral CI users, and there was no clear practice guidance for fitting and maintaining the contralateral HA in most regions. CI professionals recognised the value of fitting contralateral HAs at CI services, with audiology departments and private HA dispensers playing an ongoing role in general maintenance and support.
- 3 July 2024
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 25 (4) , 260-274
Open AccessInternational survey of bimodal hearing and bilateral cochlear implant service provision for adults
As cochlear implant (CI) criteria widen, more candidates with usable residual hearing are being considered for a CI. Unlike children, adults mostly receive only one implant. The aim of this survey was to determine bimodal-hearing and bilateral CI service provision for adults around the world. This survey offers the backdrop against which future clinical practice and service delivery can be considered. CI professionals from across the world were invited to participate in an international multicentre survey. The online questionnaire was circulated to CI professionals in 75 countries. There were 64 respondents, representing 25 countries across five world regions. In this sample, adult CI users most had unilateral CI (74.5%) and only 25.5% were bilateral CI users. Some 54% of unilateral CI users used a hearing aid (HA) in the non-implanted ear. Funding for a second implant or HA was not well supported for adult unilateral CI users, and there was no clear practice guidance for fitting and maintaining the contralateral HA in most regions. CI professionals recognised the value of fitting contralateral HAs at CI services, with audiology departments and private HA dispensers playing an ongoing role in general maintenance and support.
- Open Access
- 3 May 2024
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 64 (3) , 243-252
Integrated bimodal fitting and binaural streaming technology outcomes for unilateral cochlear implant users
Adults typically receive only one cochlear implant (CI) due to cost constraints, with a contralateral hearing aid recommended when there is aidable hearing. Standard hearing aids differ from a CI in terms of processing strategy and function as a separate entity, requiring the user to integrate the disparate signals. Integrated bimodal technology has recently been introduced to address this challenge. The aim of the study was to investigate the performance of unilateral CI users with and without an integrated bimodal fitting and determine whether binaural streaming technology offers additional benefit. Twenty-six CI users using integrated bimodal technology. Repeated measures where outcomes and user experience were assessed using a functional test battery more representative of real life listening (speech perception in noise tests, localisation test, tracking test) and the speech, spatial and qualities-of-hearing scale (SSQ). Bimodal outcomes were significantly better than for CI alone. Speech perception in noise improvements ranged from 1.4 dB to 3.5 dB depending on the location of speech and noise. The localisation and tracking tests, and the SSQ also showed significant improvements. Binaural streaming offered additional improvement (1.2 dB to 6.1 dB on the different speech tests). Integrated bimodal and binaural streaming technology improved the performance of unilateral CI users.
- 3 May 2024
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 64 (3) , 243-252
Open AccessIntegrated bimodal fitting and binaural streaming technology outcomes for unilateral cochlear implant users
Adults typically receive only one cochlear implant (CI) due to cost constraints, with a contralateral hearing aid recommended when there is aidable hearing. Standard hearing aids differ from a CI in terms of processing strategy and function as a separate entity, requiring the user to integrate the disparate signals. Integrated bimodal technology has recently been introduced to address this challenge. The aim of the study was to investigate the performance of unilateral CI users with and without an integrated bimodal fitting and determine whether binaural streaming technology offers additional benefit. Twenty-six CI users using integrated bimodal technology. Repeated measures where outcomes and user experience were assessed using a functional test battery more representative of real life listening (speech perception in noise tests, localisation test, tracking test) and the speech, spatial and qualities-of-hearing scale (SSQ). Bimodal outcomes were significantly better than for CI alone. Speech perception in noise improvements ranged from 1.4 dB to 3.5 dB depending on the location of speech and noise. The localisation and tracking tests, and the SSQ also showed significant improvements. Binaural streaming offered additional improvement (1.2 dB to 6.1 dB on the different speech tests). Integrated bimodal and binaural streaming technology improved the performance of unilateral CI users.