Patricia Wieland
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Patricia Wieland has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Birgit Flechl
MedAustron Ion Therapy Center, 2700 Wiener Neustadt, Austria
1 shared publication - Carola Lütgendorf-Caucig
MedAustron Ion Therapy Center, 2700 Wiener Neustadt, Austria
1 shared publication - Eugen Hug
MedAustron Ion Therapy Center, 2700 Wiener Neustadt, Austria
1 shared publication - Irina Pradler
MedAustron Ion Therapy Center, 2700 Wiener Neustadt, Austria
1 shared publication - Maciej J. Pelak
MedAustron Ion Therapy Center, Wiener Neustadt, Austria; University Clinic for Radiotherapy and Radiation Oncology of the Paracelsus Medical University of Salzburg, Salzburg, Austria
1 shared publication - Marta Mumot
MedAustron Ion Therapy Center, 2700 Wiener Neustadt, Austria
1 shared publication
Latest Publications
- Open Access
The Value of PET/CT in Particle Therapy Planning of Various Tumors with SSTR2 Receptor Expression: Comparative Interobserver Study
The overexpression of somatostatin receptor type 2 (SSTR2) is a property of various tumor types. Hybrid imaging utilizing [68Ga]1,4,7,10-tetraazacyclododecane-1,4,7,10-tetra-acetic acid (DOTA) may improve the differentiation between tumor and healthy tissue. We conducted an experimental study on 47 anonymized patient cases including 30 meningiomas, 12 PitNET and 5 SBPGL. Four independent observers were instructed to contour the macroscopic tumor volume on planning MRI and then reassess their volumes with the additional information from DOTA-PET/CT. The conformity between observers and reference volumes was assessed. In total, 46 cases (97.9%) were DOTA-avid and included in the final analysis. In eight cases, PET/CT additional tumor volume was identified that was not detected by MRI; these PET/CT findings were potentially critical for the treatment plan in four cases. For meningiomas, the interobserver and observer to reference volume conformity indices were higher with PET/CT. For PitNET, the volumes had higher conformity between observers with MRI. With regard to SBGDL, no significant trend towards conformity with the addition of PET/CT information was observed. DOTA PET/CT supports accurate tumor recognition in meningioma and PitNET and is recommended in SSTR2-expressing tumors planned for treatment with highly conformal radiation.
Open AccessThe Value of PET/CT in Particle Therapy Planning of Various Tumors with SSTR2 Receptor Expression: Comparative Interobserver Study
The overexpression of somatostatin receptor type 2 (SSTR2) is a property of various tumor types. Hybrid imaging utilizing [68Ga]1,4,7,10-tetraazacyclododecane-1,4,7,10-tetra-acetic acid (DOTA) may improve the differentiation between tumor and healthy tissue. We conducted an experimental study on 47 anonymized patient cases including 30 meningiomas, 12 PitNET and 5 SBPGL. Four independent observers were instructed to contour the macroscopic tumor volume on planning MRI and then reassess their volumes with the additional information from DOTA-PET/CT. The conformity between observers and reference volumes was assessed. In total, 46 cases (97.9%) were DOTA-avid and included in the final analysis. In eight cases, PET/CT additional tumor volume was identified that was not detected by MRI; these PET/CT findings were potentially critical for the treatment plan in four cases. For meningiomas, the interobserver and observer to reference volume conformity indices were higher with PET/CT. For PitNET, the volumes had higher conformity between observers with MRI. With regard to SBGDL, no significant trend towards conformity with the addition of PET/CT information was observed. DOTA PET/CT supports accurate tumor recognition in meningioma and PitNET and is recommended in SSTR2-expressing tumors planned for treatment with highly conformal radiation.