Tsuyoshi Shirai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tsuyoshi Shirai has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Kyohei Natsume
National Institute for Materials Science, Tsukuba, Japan
3 shared publications - Koji Kamiya
National Institute for Materials Science, Tsukuba, Japan
2 shared publications - Akira Uchida
National Institute for Materials Science, Tsukuba, Japan
1 shared publication - Gen Nishijima
National Institute for Materials Science (NIMS), Tsukuba, Japan
1 shared publication - Hiroshi Miyazaki
Kyushu University, Fukuoka, Japan
1 shared publication - Koichi Matsumoto
Department of Physics, Kanazawa University, Kanazawa 920-1192, Japan
1 shared publication
Latest Publications
- 22 October 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 372
Multilayer active magnetic regenerator refrigeration for high-efficiency hydrogen liquefaction
- 22 October 2026
- Published by Elsevier in Energy Conversion and Management
- Vol. 372
Multilayer active magnetic regenerator refrigeration for high-efficiency hydrogen liquefaction
- Open Access
- 25 July 2026
- Published by Elsevier in SSRN Electronic Journal
Multilayer active magnetic regenerator refrigeration for high-efficiency hydrogen liquefaction
Magnetocaloric refrigeration has been introduced as a more efficient refrigeration technology than conventional Joule-Thomson expansion technologies. It can be significantly used to liquefy hydrogen, reaching the cryogenic liquefaction temperature of 20 K or beyond. The system mainly comprises an active magnetic regenerator (AMR) packed with magnetocaloric material, and a magnetic source composed of a NbTi superconducting magnet. Due to the appreciable magnetocaloric effect and wide operational range of HoAl2, it is commonly used for hydrogen liquefaction applications. To further improve the performance of multilayer AMRs, which are used to widen the operating temperature span, careful selection and arrangement of the layers are required to minimize entropy transfer losses between adjacent materials. In the present study, dual multilayers of ErAl2 + HoAl2 and HoB2 + HoAl2 are examined to investigate their feasibility against the HoAl2 single layer. Meanwhile, different packing ratios of these materials are used to attain optimal composition and compare their performance. A finite element model using COMSOL Multiphysics is validated with an experimental setup and developed to explore the spatio-temporal evolution of AMR temperature and, accordingly, evaluate the performance in terms of the refrigeration capacity (QR) and figure of merit (FOM). The results exhibit that the ErAl2 + HoAl2 dual multilayer achieves a slightly higher QR of 87.9 W compared to HoB2 + HoAl2 (84.9 W), whereas single-layer HoAl2 attains a QR of only 55.3 W. This is mainly attributed to the combined magnetocaloric effect (MCE) of multilayer AMR. Moreover, due to the innate MCE of ErAl2 + HoAl2, it yields a FOM of up to 0.809, whereas HoB2 + HoAl2 and HoAl2 only reach 0.418 and 0.514, respectively. This emphasizes the advantage of dual-layer magnetocaloric materials in enhancing both cooling capacity and efficiency, and provides a solid foundation for the development of efficient magnetic refrigeration systems for hydrogen liquefaction applications.
- 25 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMultilayer active magnetic regenerator refrigeration for high-efficiency hydrogen liquefaction
Magnetocaloric refrigeration has been introduced as a more efficient refrigeration technology than conventional Joule-Thomson expansion technologies. It can be significantly used to liquefy hydrogen, reaching the cryogenic liquefaction temperature of 20 K or beyond. The system mainly comprises an active magnetic regenerator (AMR) packed with magnetocaloric material, and a magnetic source composed of a NbTi superconducting magnet. Due to the appreciable magnetocaloric effect and wide operational range of HoAl2, it is commonly used for hydrogen liquefaction applications. To further improve the performance of multilayer AMRs, which are used to widen the operating temperature span, careful selection and arrangement of the layers are required to minimize entropy transfer losses between adjacent materials. In the present study, dual multilayers of ErAl2 + HoAl2 and HoB2 + HoAl2 are examined to investigate their feasibility against the HoAl2 single layer. Meanwhile, different packing ratios of these materials are used to attain optimal composition and compare their performance. A finite element model using COMSOL Multiphysics is validated with an experimental setup and developed to explore the spatio-temporal evolution of AMR temperature and, accordingly, evaluate the performance in terms of the refrigeration capacity (QR) and figure of merit (FOM). The results exhibit that the ErAl2 + HoAl2 dual multilayer achieves a slightly higher QR of 87.9 W compared to HoB2 + HoAl2 (84.9 W), whereas single-layer HoAl2 attains a QR of only 55.3 W. This is mainly attributed to the combined magnetocaloric effect (MCE) of multilayer AMR. Moreover, due to the innate MCE of ErAl2 + HoAl2, it yields a FOM of up to 0.809, whereas HoB2 + HoAl2 and HoAl2 only reach 0.418 and 0.514, respectively. This emphasizes the advantage of dual-layer magnetocaloric materials in enhancing both cooling capacity and efficiency, and provides a solid foundation for the development of efficient magnetic refrigeration systems for hydrogen liquefaction applications.
- 2 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Effects of Moving Magnetic Materials in and out of Superconducting Magnet for Active Magnetic Regenerative Refrigeration System
A reciprocating type active magnetic regenerative refrigeration (AMR) utilizes the magnetocaloric effect of magnetic materials which occurs during magnetization and demagnetization processes by moving magnetic materials in and out of a magnet. Estimating the induced voltage and electromagnetic force in the superconducting magnet during the reciprocation is crucial to optimize the design of the AMR system. This paper represents the behavior of the superconducting magnet during the AMR operation that the magnetic material HoAl 2 weighing 250 g enters and exits the 120 mm bore NbTi superconducting coil. The calculation and measurement results of the induced voltage and electromagnetic force in the magnetic field of 0–5 T at 25 K were reported.
- 2 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Effects of Moving Magnetic Materials in and out of Superconducting Magnet for Active Magnetic Regenerative Refrigeration System
A reciprocating type active magnetic regenerative refrigeration (AMR) utilizes the magnetocaloric effect of magnetic materials which occurs during magnetization and demagnetization processes by moving magnetic materials in and out of a magnet. Estimating the induced voltage and electromagnetic force in the superconducting magnet during the reciprocation is crucial to optimize the design of the AMR system. This paper represents the behavior of the superconducting magnet during the AMR operation that the magnetic material HoAl 2 weighing 250 g enters and exits the 120 mm bore NbTi superconducting coil. The calculation and measurement results of the induced voltage and electromagnetic force in the magnetic field of 0–5 T at 25 K were reported.