ATAndrei N. Tintu

Andrei N. Tintu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrei N. Tintu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Albert J. de Graaf

    Department of Clinical Chemistry and Laboratory Medicine , Medisch Spectrum Twente , Enschede , The Netherlands

    2 shared publications
  • Heleen van der Sijs

    Department of Hospital Pharmacy , Erasmus MC, University Medical Center Rotterdam , Rotterdam , The Netherlands

    2 shared publications
  • Johannes G. Krabbe

    Department of Clinical Chemistry and Laboratory Medicine, Medisch Spectrum Twente, Medlon B.V., 7512 KZ Enschede, The Netherlands

    2 shared publications
  • Lale Erdem-Eraslan

    Department of Clinical Chemistry , Erasmus MC, University Medical Center , Rotterdam , The Netherlands

    2 shared publications
  • Rolf J. Verheul

    Department of Clinical Chemistry and Laboratory Medicine , Haaglanden Medical Centre , The Hague , The Netherlands

    2 shared publications
  • Ron Kusters

    Laboratory for Clinical Chemistry and Haematology, Jeroen Bosch Hospital , ’s-Hertogenbosch , The Netherlands

    2 shared publications

Latest Publications

  • Open Access

    Evaluation of Total Bilirubin in a National Quality Program

    by Lauren E H Westenberg, Marith van Schrojenstein Lantman, Miranda van Berkel, Marc H M Thelen, Andrei Tintu, Jolande Y Vis, Cas W Weykamp, Marlies Oostendorp, Marieke Frasa, Jenny E Kootstra-Ros, et al.

    Background: Accurate quantification of neonatal bilirubin remains a perennial challenge. To monitor analytical performance of total bilirubin measurements across hospitals in the Netherlands, a dedicated neonatal external quality assessment (EQA) program is in place. Methods: We retrospectively analyzed Dutch EQA data from 2013 until 2025. Each year, the 81 participating laboratories received 24 pooled adult blood serum samples spiked with unconjugated bilirubin (range 100–400 µmol/L or 5.85–23.40 mg/dL). Bias from the target value determined by the reference measurement procedure (RMP) and the coefficient of variation (CV) were established for both unfactored and factored measurements. Results: In total, 25 983 bilirubin measurements were analyzed. Three analytical principles were used on 12 platforms from 6 manufacturers. Diazo-based methods exhibited the lowest median bias (+0.4% in 2024), alongside spectrophotometric methods (−3.8% in 2024). Vanadate-based methods showed a bias of +19.5% in 2024 that was reduced to +3.0% for factored measurements. Substantial differences in bias were observed among manufacturers and platforms, with some exhibiting concentration dependency. Comparable patterns were seen for CVs, which generally remained below 5%. Conclusion: EQA results demonstrated temporal variability in bias across all analytical principles, manufacturers, and platforms used for neonatal bilirubin assays. Bias was found to vary with bilirubin concentration. Standardization of neonatal bilirubin assays is urgently needed to ensure more reliable and accurate measurements across different systems. Meanwhile, EQA programs are important in monitoring future assay adjustments to ensure appropriate and consistent management of neonatal hyperbilirubinemia.


  • Open Access

    The influence of undetected hemolysis on POCT potassium results in the emergency department

    by Andrei N. Tintu, Antonio Buño Soto, Viviane Van Hoof, Suzanne Bench, Anthony Malpass, Ulf Martin Schilling, Kevin Rooney, Paloma Oliver Sáez, Lasse Relker, Peter Luppa

    Objectives: This study aimed to evaluate discrepancies in potassium measurements between point-of-care testing (POCT) and central laboratory (CL) methods, focusing on the impact of hemolysis on these measurements and its impact in the clinical practice in the emergency department (ED). Methods: A retrospective analysis was conducted using data from three European university hospitals: Technische Universitat München (Germany), Hospital Universitario La Paz (Spain), and Erasmus University Medical Center (The Netherlands). The study compared POCT potassium measurements in EDs with CL measurements. Data normalization was performed in categories for potassium levels (kalemia) and hemolysis. The severity of discrepancies between POCT and CL potassium measurements was assessed using the reference change value (RCV). Results: The study identified significant discrepancies in potassium between POCT and CL methods. In comparing POCT normo- and mild hypokalemia against CL results, differences of −4.20 % and +4.88 % were noted respectively. The largest variance in the CL was a +4.14 % difference in the mild hyperkalemia category. Additionally, the RCV was calculated to quantify the severity of discrepancies between paired potassium measurements from POCT and CL methods. The overall hemolysis characteristics, as defined by the hemolysis gradient, showed considerable variation between the testing sites, significantly affecting the reliability of potassium measurements in POCT. Conclusions: The study highlighted the challenges in achieving consistent potassium measurement results between POCT and CL methods, particularly in the presence of hemolysis. It emphasised the need for integrated hemolysis detection systems in future blood gas analysis devices to minimise discrepancies and ensure accurate POCT results.


  • Real-time monitoring of drug laboratory test interactions: a proof of concept

    by Jasmijn A. van Balveren, Wilhelmine P.H.G. Verboeket-Van de Venne, Carine J.M. Doggen, Lale Erdem-Eraslan, Albert J. de Graaf, Johannes G. Krabbe, Ruben E.A. Musson, Wytze P. Oosterhuis, Yolanda B. de Rijke, Heleen van der Sijs, et al.

    Objectives: For the correct interpretation of test results, it is important to be aware of drug-laboratory test interactions (DLTIs). If DLTIs are not taken into account by clinicians, erroneous interpretation of test results may lead to a delayed or incorrect diagnosis, unnecessary diagnostic testing or therapy with possible harm for patients. A DLTI alert accompanying a laboratory test result could be a solution. The aim of this study was to test a multicentre proof of concept of an electronic clinical decision support system (CDSS) for real-time monitoring of DLTIs. Methods: CDSS was implemented in three Dutch hospitals. So-called ‘clinical rules’ were programmed to alert medical specialists for possible DLTIs based on laboratory test results outside the reference range in combination with prescribed drugs. A selection of interactions from the DLTI database of the Dutch society of clinical chemistry and laboratory medicine were integrated in 43 clinical rules, including 24 tests and 25 drugs. During the period of one month all generated DTLI alerts were registered in the laboratory information system. Results: Approximately 65 DLTI alerts per day were detected in each hospital. Most DLTI alerts were generated in patients from the internal medicine and intensive care departments. The most frequently reported DLTI alerts were potassium-proton pump inhibitors (16%), potassium-beta blockers (11%) and creatine kinase-statins (11%). Conclusions: This study shows that it is possible to alert for potential DLTIs in real-time with a CDSS. The CDSS was successfully implemented in three hospitals. Further research must reveal its usefulness in clinical practice.


  • Clinical usefulness of drug-laboratory test interaction alerts: a multicentre survey

    by Jasmijn A. van Balveren, Wilhelmine P. H. G. Verboeket-Van de Venne, Carine J. M. Doggen, Anne S. Cornelissen, Lale Erdem-Eraslan, Albert J. de Graaf, Johannes G. Krabbe, Ruben E. A. Musson, Wytze P. Oosterhuis, Yolanda B. de Rijke, et al.

    Objectives: Knowledge of possible drug-laboratory test interactions (DLTIs) is important for the interpretation of laboratory test results. Failure to recognize these interactions may lead to misinterpretation, a delayed or erroneous diagnosis, or unnecessary extra diagnostic tests or therapy, which may harm patients. The aim of this multicentre survey was to evaluate the clinical value of DLTI alerts. Methods: A survey was designed with six predefined clinical cases selected from the clinical laboratory practice with a potential DLTI. Physicians from several departments, including internal medicine, cardiology, intensive care, surgery and geriatrics in six participating hospitals were recruited to fill in the survey. The survey addressed their knowledge of DLTIs, motivation to receive an alert and opinion on the potential influence on medical decision making. Results: A total of 210 physicians completed the survey. Of these respondents 93% had a positive attitude towards receiving DLTI alerts; however, the reported value differed per case and per respondent’s background. In each clinical case, medical decision making was influenced as a consequence of the reported DLTI message (ranging from 3 to 45% of respondents per case). Conclusions: In this multicentre survey, most physicians stated DLTI messages to be useful in laboratory test interpretation. Medical decision making was influenced by reporting DLTI alerts in each case. Alerts should be adjusted according to the needs and preferences of the receiving physicians.