XLXinjia Li

Xinjia Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xinjia Li has a total of 37 co-authors. Here are the top co-authors by number of shared publications:

  • Hao Quan

    State Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China

    4 shared publications
  • Long Meng

    Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China

    3 shared publications
  • Pengqi Li

    State Key Laboratory of Biomedical Imaging Science and System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong 518055, China

    3 shared publications
  • Wei Zhou

    Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Shenzhen 518055, China

    3 shared publications
  • Xiufang Liu

    Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Shenzhen 518055, China

    3 shared publications
  • Benxian Peng

    Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences , Shenzhen, Guangdong 518055, People's Republic of China

    1 shared publication

Latest Publications

  • Acoustic separation of cells and bacteria in open sessile droplets

    by Xiufang Liu, Xinjia Li, Hao Quan, Ziwen Yu, Xiaomeng Ji, Pengqi Li, Wei Zhou, Long Meng


  • Tunable particle-free region via acoustic force balance around an oscillating microbubble

    by Wenjun Zhang, Xinjia Li, Zhigang Wang, Hao Quan, Xiufang Liu

  • Top Cited Papers
    Open Access

    Augmenting ultrasound for continuous glucose monitoring via a wearable acoustically readable microneedle patch

    by Wanglinhan Zhang, Jiangang Xu, Xinjia Li, Yeji Jang, Qiqi Liu, Weixin Ma, Guojie Luo, Ming Ma, Qingqing Wang, Yi He, et al.

    Continuous glucose monitoring (CGM) represents substantial advancement, yet poses a challenge in wearable health care development. Current enzymatic CGM faces limitations in stability, cost, and durability. We introduce an enzyme-free, wearable acoustically readable microneedle patch (ARMPatch) composed of glucose-responsive hydrogel. Positioned between a standard ultrasound probe and the skin, ARMPatch acts as an acoustic interface enabling CGM using conventional ultrasound. Its hydrogel microneedles minimally penetrate the epidermis, allowing interstitial fluid to trigger variable swelling of the microneedles in response to glucose fluctuations. ARMPatch delivers stable and selective glucose readings for up to 56 days. Glucose variations with millimolar resolution are obtained via ultrasound within a response time of 30 to 60 minutes. In vivo CGM in animal models for 7 days reveals a reversible correlation between microneedle swelling and glucose variations. Acting as “accessory” for standard ultrasound probes, this approach offers a minimally invasive, cost-effective, and long-lasting solution to non-enzymatic CGM, expanding the utility of ultrasound in wearable biosensing.


  • Open Access

    Oscillating microbubble array–based metamaterials (OMAMs) for rapid isolation of high-purity exosomes

    by Xinjia Li, Zhiting Deng, Wenjun Zhang, Wei Zhou, Xiufang Liu, Hao Quan, Jiali Li, Pengqi Li, Yingyin Li, Cai Hu, et al.

    Exosomes secreted by cells hold substantial potential for disease diagnosis and treatment. However, the rapid isolation of high-purity exosomes and their subpopulations from biofluids (e.g., undiluted whole blood) remains challenging. This study presents oscillating microbubble array–based metamaterials (OMAMs) for enabling the rapid isolation of high-purity exosomes and their subpopulations from biofluids without labeling or preprocessing. Particularly, leveraging acoustically excited microbubble oscillation, OMAMs can generate numerous acoustofluidic traps for filtering in-fluid micro/nanoparticles, thus allowing for removing bioparticles larger than exosomes to obtain high-purity (93%) exosomes from undiluted whole blood in ~3 minutes. Moreover, exosome subpopulations in different size ranges can be isolated by tuning the microbubble oscillation amplitude. Additionally, as each oscillating microbubble functions as an ultradeep subwavelength (~λ/186) acoustic amplifier and a nonlinear source, OMAMs can generate high-resolution complex acoustic energy patterns and tune the patterns by activating different-sized microbubbles at their distinct resonance frequencies.


  • Quasi-Bessel surface acoustic wave for dynamic acoustic manipulation

    by Jingyao Shi, Chunqiu Zhang, Pengqi Li, Benxian Peng, Xinjia Li, Xiufang Liu, Wei Zhou

    Acoustic manipulation using surface acoustic wave has aroused widespread interest in life sciences, biomedical, and bioanalytical chemistry. Acoustic manipulation for different applications requires different acoustic fields. Bessel beams are non-diffractive and re-constructable, bringing possibility and versatility of acoustic manipulation integrated on microfluidic chips. To date, there are a few studies on constructing Bessel surface acoustic waves. Moreover, there is still a lack of dynamic acoustic manipulation using Bessel surface acoustic waves propagating along a surface of piezoelectric substrate with simple and high-precision devices. Here, we design a device with two omnidirectional equifrequency interdigital transducers to form a quasi-Bessel surface acoustic wave by means of coherent interference. The proposed device avoids influences of anisotropy on its operating frequency, making its quasi-Bessel beam accurately and stably conform to the predetermined design acoustic field. This acoustic field could control micrometer to submicrometer particles and dynamically move particles along lateral direction and axial direction of the propagation of quasi-Bessel beam. A phenomenon similar to negative force appeared when the two-micron spherical particles were manipulated. The quasi-Bessel beam formed by our device can provide a versatile movement for on-chip acoustic manipulation.


  • Top Cited Papers

    Dual-Channel Prototype Network for Few-Shot Pathology Image Classification

    by Hao Quan, Xinjia Li, Dayu Hu, Tianhang Nan, Xiaoyu Cui

    In the field of pathology, the scarcity of certain diseases and the difficulty of annotating images hinder the development of large, high-quality datasets, which in turn affects the advancement of deep learning-assisted diagnostics. Few-shot learning has demonstrated unique advantages in modeling tasks with limited data, yet explorations of this method in the field of pathology remain in the early stages. To address this issue, we present a dual-channel prototype network (DCPN), a novel few-shot learning approach for efficiently classifying pathology images with limited data. The DCPN leverages self-supervised learning to extend the pyramid vision transformer (PVT) to few-shot classification tasks and combines it with a convolutional neural network to construct a dual-channel network for extracting multi-scale, high-precision pathological features, thereby substantially enhancing the generalizability of prototype representations. Additionally, we design a soft voting classifier based on multi-scale features to further augment the discriminative power of the model in complex pathology image classification tasks. We constructed three few-shot classification tasks with varying degrees of domain shift using three publicly available pathological datasets—CRCTP, NCTCRC, and LC25000—to emulate real-world clinical scenarios. The results demonstrated that the DCPN outperformed the prototypical network across all metrics, achieving the highest accuracies in same-domain tasks—70.86% for 1-shot, 82.57% for 5-shot, and 85.2% for 10-shot setups—corresponding to improvements of 5.51%, 5.72%, and 6.81%, respectively, over the prototypical network. Notably, in the same-domain 10-shot setting, the accuracy of the DCPN (85.2%) surpassed that of the PVT-based supervised learning model (85.15%), confirming its potential to diagnose rare diseases within few-shot learning frameworks.