ZZZhi-Wen Zhang

Zhi-Wen Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhi-Wen Zhang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI

    by Xue-Han Wu, Yu-Tao Que, Xin-Yue Yang, Zi-Qiang Wen, Yu-Ru Ma, Zhi-Wen Zhang, Quan-Meng Liu, Wen-Jie Fan, Li Ding, Yue-Jiao Lang, et al.

    Wu XH, et al. Korean J Radiol. 2025 Mar;26:e37. https://doi.org/10.3348/kjr.2024.0767


  • Value of orthogonal axial MR images in preoperative T staging of gastric cancer

    by Quan-Meng Liu, Yan Chen, Wen-Jie Fan, Xue-Han Wu, Zhi-Wen Zhang, Bao-Lan Lu, Yu-Ru Ma, Yi-Yan Liu, Yun-Zhu Wu, Shen-Ping Yu, et al.

    Purpose To assess the value of orthogonal axial images (OAI) of MRI in gastric cancer T staging. Methods This retrospective study enrolled 133 patients (median age, 63 [range, 24–85] years) with gastric adenocarcinoma who underwent both CT and MRI followed by surgery. MRI lacking or incorporating OAI and CT images were evaluated, respectively. Diagnostic performance (accuracy, sensitivity, and specificity) for each T stage, overall diagnostic accuracy and rates of over- and understaging were quantified employing pathological T stage as a reference standard. The McNemar’s test was performed to compare the overall accuracy. Results Among patients with pT1–pT4 disease, MRI with OAI (accuracy: 88.7–94.7%, sensitivity: 66.7–93.0%, specificity: 91.5–100.0%) exhibited superior diagnostic performance compared to MRI without OAI (accuracy: 81.2–88.7%, sensitivity: 46.2–83.1%, specificity: 85.5–99.1%) and CT (accuracy: 88.0–92.5%, sensitivity: 53.3–90.1%, specificity: 88.7–98.1%). The overall accuracy of MRI with OAI was significantly higher (83.5%) than that of MRI without OAI (67.7%) (p < .001). However, there was no significant difference in the overall accuracy of MRI with OAI and CT (78.9%) (p = .35). The over- and understaging rates of MRI with OAI (12.0, 4.5%) were lower than those of MRI without OAI (21.8, 10.5%) and CT (12.8, 8.3%). Conclusion OAI play a pivotal role in the T staging of gastric cancer. MRI incorporating OAI demonstrated commendable performance for gastric cancer T-staging, with a slight tendency toward its superiority over CT.