Thomas Kampf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Thomas Kampf has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Christian Herbert Ziener
Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
3 shared publications - Peter Michael Jakob
Experimental Physics 5 University of Würzburg Würzburg Germany
3 shared publications - Lukas Reinhold Buschle
German Cancer Research Center, E010 Radiology, INF 280, D-69120 Heidelberg, Germany
2 shared publications A. Fischer
University of Würzburg
1 shared publication- Alma Zernecke
Institute of Experimental Biomedicine, University Hospital Würzburg , Josef-Schneider-Str. 2, D16, Würzburg 97080
1 shared publication - Anton Xu
Department of Translational Research, Comprehensive Heart Failure Center (CHFC), University Hospital Würzburg, 97080 Würzburg, Germany
1 shared publication
Latest Publications
- Open Access
- 7 December 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (12) , 1856
2D Projection Maps of WSS and OSI Reveal Distinct Spatiotemporal Changes in Hemodynamics in the Murine Aorta during Ageing and Atherosclerosis
Growth, ageing and atherosclerotic plaque development alter the biomechanical forces acting on the vessel wall. However, monitoring the detailed local changes in wall shear stress (WSS) at distinct sites of the murine aortic arch over time has been challenging. Here, we studied the temporal and spatial changes in flow, WSS, oscillatory shear index (OSI) and elastic properties of healthy wildtype (WT, n = 5) and atherosclerotic apolipoprotein E-deficient (Apoe−/−, n = 6) mice during ageing and atherosclerosis using high-resolution 4D flow magnetic resonance imaging (MRI). Spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated, allowing the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and local correlations between WSS, pulse wave velocity (PWV), plaque and vessel wall characteristics. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe−/− mice, and we identified the circumferential WSS as potential marker of plaque size and composition in advanced atherosclerosis and the radial strain as a potential marker for vascular elasticity. Two-dimensional (2D) projection maps of WSS and OSI, including statistical analysis provide a powerful tool to monitor local aortic hemodynamics during ageing and atherosclerosis. The correlation of spatially resolved hemodynamics and plaque characteristics could significantly improve our understanding of the impact of hemodynamics on atherosclerosis, which may be key to understand plaque progression towards vulnerability.
- 7 December 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (12) , 1856
Open Access2D Projection Maps of WSS and OSI Reveal Distinct Spatiotemporal Changes in Hemodynamics in the Murine Aorta during Ageing and Atherosclerosis
Growth, ageing and atherosclerotic plaque development alter the biomechanical forces acting on the vessel wall. However, monitoring the detailed local changes in wall shear stress (WSS) at distinct sites of the murine aortic arch over time has been challenging. Here, we studied the temporal and spatial changes in flow, WSS, oscillatory shear index (OSI) and elastic properties of healthy wildtype (WT, n = 5) and atherosclerotic apolipoprotein E-deficient (Apoe−/−, n = 6) mice during ageing and atherosclerosis using high-resolution 4D flow magnetic resonance imaging (MRI). Spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated, allowing the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and local correlations between WSS, pulse wave velocity (PWV), plaque and vessel wall characteristics. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe−/− mice, and we identified the circumferential WSS as potential marker of plaque size and composition in advanced atherosclerosis and the radial strain as a potential marker for vascular elasticity. Two-dimensional (2D) projection maps of WSS and OSI, including statistical analysis provide a powerful tool to monitor local aortic hemodynamics during ageing and atherosclerosis. The correlation of spatially resolved hemodynamics and plaque characteristics could significantly improve our understanding of the impact of hemodynamics on atherosclerosis, which may be key to understand plaque progression towards vulnerability.
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s475-s480
Session 45. Imaging and image processing IV – MRI
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s475-s480
Session 45. Imaging and image processing IV – MRI
- Open Access
- 4 August 2015
- Published by Springer Nature in SpringerPlus
- Vol. 4 (1) , 1-26
Orthogonality, Lommel integrals and cross product zeros of linear combinations of Bessel functions
The cylindrical Bessel differential equation and the spherical Bessel differential equation in the interval $$R \le r \le \gamma R$$ with Neumann boundary conditions are considered. The eigenfunctions are linear combinations of the Bessel function $$\Phi _{n,\nu }(r)=Y_{\nu }^{\prime }(\lambda _{n,\nu }) J_{\nu }(\lambda _{n,\nu } r/R)-J_{\nu }^{\prime }(\lambda _{n,\nu }) Y_{\nu }(\lambda _{n,\nu } r/R)$$ or linear combinations of the spherical Bessel functions $$\psi _{m,\nu }(r)=y_{\nu }^{\prime }(\lambda _{m,\nu }) j_{\nu }(\lambda _{m,\nu } r/R)-j_{\nu }^{\prime }(\lambda _{m,\nu }) y_{\nu }(\lambda _{m,\nu } r/R)$$ . The orthogonality relations with analytical expressions for the normalization constant are given. Explicit expressions for the Lommel integrals in terms of Lommel functions are derived. The cross product zeros $$Y_{\nu }^{\prime }(\lambda _{n,\nu }) J_{\nu }^{\prime }(\gamma \lambda _{n,\nu })-J_{\nu }^{\prime }(\lambda _{n,\nu }) Y_{\nu }^{\prime }(\gamma \lambda _{n,\nu }) = 0$$ and $$y_{\nu }^{\prime }(\lambda _{m,\nu }) j_{\nu }^{\prime }(\gamma \lambda _{m,\nu })-j_{\nu }^{\prime }(\lambda _{m,\nu }) y_{\nu }^{\prime }(\gamma \lambda _{m,\nu }) = 0$$ are considered in the complex plane for real as well as complex values of the index $$\nu $$ and approximations for the exceptional zero $$\lambda _{1,\nu }$$ are obtained. A numerical scheme based on the discretization of the two-dimensional and three-dimensional Laplace operator with Neumann boundary conditions is presented. Explicit representations of the radial part of the Laplace operator in form of a tridiagonal matrix allow the simple computation of the cross product zeros.- 4 August 2015
- Published by Springer Nature in SpringerPlus
- Vol. 4 (1) , 1-26
Open AccessOrthogonality, Lommel integrals and cross product zeros of linear combinations of Bessel functions
The cylindrical Bessel differential equation and the spherical Bessel differential equation in the interval $$R \le r \le \gamma R$$ with Neumann boundary conditions are considered. The eigenfunctions are linear combinations of the Bessel function $$\Phi _{n,\nu }(r)=Y_{\nu }^{\prime }(\lambda _{n,\nu }) J_{\nu }(\lambda _{n,\nu } r/R)-J_{\nu }^{\prime }(\lambda _{n,\nu }) Y_{\nu }(\lambda _{n,\nu } r/R)$$ or linear combinations of the spherical Bessel functions $$\psi _{m,\nu }(r)=y_{\nu }^{\prime }(\lambda _{m,\nu }) j_{\nu }(\lambda _{m,\nu } r/R)-j_{\nu }^{\prime }(\lambda _{m,\nu }) y_{\nu }(\lambda _{m,\nu } r/R)$$ . The orthogonality relations with analytical expressions for the normalization constant are given. Explicit expressions for the Lommel integrals in terms of Lommel functions are derived. The cross product zeros $$Y_{\nu }^{\prime }(\lambda _{n,\nu }) J_{\nu }^{\prime }(\gamma \lambda _{n,\nu })-J_{\nu }^{\prime }(\lambda _{n,\nu }) Y_{\nu }^{\prime }(\gamma \lambda _{n,\nu }) = 0$$ and $$y_{\nu }^{\prime }(\lambda _{m,\nu }) j_{\nu }^{\prime }(\gamma \lambda _{m,\nu })-j_{\nu }^{\prime }(\lambda _{m,\nu }) y_{\nu }^{\prime }(\gamma \lambda _{m,\nu }) = 0$$ are considered in the complex plane for real as well as complex values of the index $$\nu $$ and approximations for the exceptional zero $$\lambda _{1,\nu }$$ are obtained. A numerical scheme based on the discretization of the two-dimensional and three-dimensional Laplace operator with Neumann boundary conditions is presented. Explicit representations of the radial part of the Laplace operator in form of a tridiagonal matrix allow the simple computation of the cross product zeros. - Open Access
- 8 July 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (5) , 1784-1797
Myocardial perfusion quantification using theT1-based FAIR-ASL method: The influence of heart anatomy, cardiopulmonary blood flow and look-locker readout
Purpose The quantification of myocardial perfusion using a Look–Locker flow-sensitive alternating inversion recovery- arterial spin labeling experiment is considered. Due to the anatomy of the heart, a substantial but unintended partial inversion of the inflowing blood occurs during the slice-selective inversion. Both, the partial inversion as well as the Look–Locker pulse train, influence the myocardial perfusion quantification and are addressed in this work. Methods The mean relaxation time approximation is used to calculate the monoexponential relaxation time of the signal in perfused tissue under Look–Locker readout. The left ventricular blood serves as an approximation of the inflowing blood in the description of FAIR-ASL measurements with global and slice-selective inversion to correctly quantify the myocardial perfusion. Results The analysis shows that the myocardial perfusion can be overestimated if the T1-based quantification method is not adapted respecting the Look–Locker pulse train explicitly. Additionally, it turns out that without correction for the partial inversion of the blood pool during the slice-selective inversion the myocardial perfusion is underestimated. Conclusion It is shown that the Look–Locker readout as well as the nonideal slice-selective inversion experiment have a considerable influence and have to be included properly to correctly quantify myocardial perfusion. Magn Reson Med 71:1784–1797, 2014.
- 8 July 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (5) , 1784-1797
Open AccessMyocardial perfusion quantification using theT1-based FAIR-ASL method: The influence of heart anatomy, cardiopulmonary blood flow and look-locker readout
Purpose The quantification of myocardial perfusion using a Look–Locker flow-sensitive alternating inversion recovery- arterial spin labeling experiment is considered. Due to the anatomy of the heart, a substantial but unintended partial inversion of the inflowing blood occurs during the slice-selective inversion. Both, the partial inversion as well as the Look–Locker pulse train, influence the myocardial perfusion quantification and are addressed in this work. Methods The mean relaxation time approximation is used to calculate the monoexponential relaxation time of the signal in perfused tissue under Look–Locker readout. The left ventricular blood serves as an approximation of the inflowing blood in the description of FAIR-ASL measurements with global and slice-selective inversion to correctly quantify the myocardial perfusion. Results The analysis shows that the myocardial perfusion can be overestimated if the T1-based quantification method is not adapted respecting the Look–Locker pulse train explicitly. Additionally, it turns out that without correction for the partial inversion of the blood pool during the slice-selective inversion the myocardial perfusion is underestimated. Conclusion It is shown that the Look–Locker readout as well as the nonideal slice-selective inversion experiment have a considerable influence and have to be included properly to correctly quantify myocardial perfusion. Magn Reson Med 71:1784–1797, 2014.
- 1 December 2010
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 207 (2) , 262-273
Application of compressed sensing to in vivo 3D 19F CSI
- 1 December 2010
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 207 (2) , 262-273
Application of compressed sensing to in vivo 3D 19F CSI