Jia-Su Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jia-Su Li has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Zhao-Shen Li
Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China
3 shared publications Bing Yu
Department of Anesthesiology, 965 Hospital of the Joint Logistics Support Force, Jilin, China
2 shared publications- Weiliang Hou
Department of Gastroenterology, National Key Laboratory of Immunity and Inflammation, Changhai Clinical Research Unit, Changhai Hospital, Naval Medical University, Shanghai, China
2 shared publications - Bufu Tang
Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
1 shared publication - Feng Liu
Digestive Endoscopy Center, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai, China
1 shared publication Jia-Quan Wu
School of Basic Medical Sciences, Naval Medical University, Shanghai, China
1 shared publication
Latest Publications
- Open Access
- 20 April 2026
- Published by Springer Nature in BMC Genomic Data
- Vol. 27 (1)
Complete genome sequence of Streptococcus periodonticum strain CRC221 isolated from human colorectal tumor tissue
Streptococcus periodonticum is a facultative anaerobic, Gram-positive coccus originally isolated from human periodontitis lesions and implicated in colorec
- 20 April 2026
- Published by Springer Nature in BMC Genomic Data
- Vol. 27 (1)
Open AccessComplete genome sequence of Streptococcus periodonticum strain CRC221 isolated from human colorectal tumor tissue
Streptococcus periodonticum is a facultative anaerobic, Gram-positive coccus originally isolated from human periodontitis lesions and implicated in colorec
- Open Access
Whole microbiota transplantation restores gut homeostasis throughout the gastrointestinal tract
This study introduces whole microbiota transplantation (WMT), a synergistic therapeutic approach that concurrently transplants small intestinal and fecal microbiota. In germ‐free mice, WMT outperforms conventional fecal microbiota transplantation (FMT) in restoring gut microbiota diversity and abundance. Moreover, in a chemotherapy‐induced intestinal mucositis model, WMT alleviates intestinal inflammation and reverses microbiota dysbiosis. Encapsulation in layer‐by‐layer self‐assembled nanocapsules further boosts microbial survival and colonization, amplifying WMT's anti‐inflammatory effects and microbiota restoration in a mouse model of pan‐intestinal infection. Overall, WMT represents a precise strategy for reshaping microbial homeostasis across the entire gastrointestinal tract, with therapeutic promise for inflammatory bowel diseases and small‐intestinal disorders.
Open AccessWhole microbiota transplantation restores gut homeostasis throughout the gastrointestinal tract
This study introduces whole microbiota transplantation (WMT), a synergistic therapeutic approach that concurrently transplants small intestinal and fecal microbiota. In germ‐free mice, WMT outperforms conventional fecal microbiota transplantation (FMT) in restoring gut microbiota diversity and abundance. Moreover, in a chemotherapy‐induced intestinal mucositis model, WMT alleviates intestinal inflammation and reverses microbiota dysbiosis. Encapsulation in layer‐by‐layer self‐assembled nanocapsules further boosts microbial survival and colonization, amplifying WMT's anti‐inflammatory effects and microbiota restoration in a mouse model of pan‐intestinal infection. Overall, WMT represents a precise strategy for reshaping microbial homeostasis across the entire gastrointestinal tract, with therapeutic promise for inflammatory bowel diseases and small‐intestinal disorders.
- 22 September 2025
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 102 (4) , 620
Self-expandable metal stents and the risk of post-ERCP pancreatitis
- 22 September 2025
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 102 (4) , 620
Self-expandable metal stents and the risk of post-ERCP pancreatitis
- Open Access
- 1 May 2025
- Published by Wolters Kluwer Health in Endoscopic Ultrasound
- Vol. 14 (3) , 151-152
An unusual case of recurrent acute pancreatitis successfully treated via precut papillotomy (with video)
- 1 May 2025
- Published by Wolters Kluwer Health in Endoscopic Ultrasound
- Vol. 14 (3) , 151-152
Open AccessAn unusual case of recurrent acute pancreatitis successfully treated via precut papillotomy (with video)
- 21 June 2024
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 119 (10) , 2141-2142
Concerns Regarding Bleeding Risk of Cold vs Hot Snare Polypectomy for Small Pedunculated Colorectal Polyps
- 21 June 2024
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 119 (10) , 2141-2142
Concerns Regarding Bleeding Risk of Cold vs Hot Snare Polypectomy for Small Pedunculated Colorectal Polyps
- 12 May 2024
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 39 (9) , 1769-1779
Adverse events in endoscopic ultrasound‐guided choledochoduodenostomy with lumen‐apposing metal stents: A systematic review and meta‐analysis
Background and Aim: Several meta‐analyses have analyzed the technical and clinical success of endoscopic ultrasound‐guided choledochoduodenostomy (EUS‐CDS) by using lumen‐apposing metal stents (LAMS) in malignant biliary obstruction, but those concerning adverse events (AEs) are scarce. The current systematic review and meta‐analysis was conducted to evaluate the AEs after EUS‐CDS with LAMS.Methods: A comprehensive literature search of PubMed, Embase, Scopus, Web of Science, and the Cochrane Library was conducted for studies reporting the outcomes of EUS‐CDS with LAMS. The main endpoints were the incidence of overall and specific AEs. Moreover, the stent dysfunction, and reintervention rates were evaluated independently.Results: A total of 21 studies (n = 1438) were included in the final meta‐analysis. The pooled rate of technical and clinical success was 93.5% (95% confidence interval [CI]: 91.3–95.1) and 88.0% (95% CI: 83.9–91.1), respectively. After EUS‐CDS with LAMS, the pooled incidence of overall AEs was 20.1% (95% CI: 16.0–24.9). The estimated rate of early AEs was 10.6% (95% CI: 7.9–14.2), and late AEs was 11.2% (95% CI: 8.2–15.2). Infection/cholangitis was the commonest AE, with a pooled incidence of 6.1% (95% CI: 3.7–10.1). The estimated incidence of stent dysfunction and reintervention was 10.5% (95% CI: 7.5–14.4), and 12.1% (95% CI: 9.3–15.7), respectively.Conclusion: Despite with a high technical and clinical success rate, EUS‐CDS with LAMS may be associated with overall AEs and stent dysfunction in one‐fifth and one‐tenth of cases, respectively. Further efforts are required to optimize its safety and long‐term stent patency.
- 12 May 2024
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 39 (9) , 1769-1779
Adverse events in endoscopic ultrasound‐guided choledochoduodenostomy with lumen‐apposing metal stents: A systematic review and meta‐analysis
Background and Aim: Several meta‐analyses have analyzed the technical and clinical success of endoscopic ultrasound‐guided choledochoduodenostomy (EUS‐CDS) by using lumen‐apposing metal stents (LAMS) in malignant biliary obstruction, but those concerning adverse events (AEs) are scarce. The current systematic review and meta‐analysis was conducted to evaluate the AEs after EUS‐CDS with LAMS.Methods: A comprehensive literature search of PubMed, Embase, Scopus, Web of Science, and the Cochrane Library was conducted for studies reporting the outcomes of EUS‐CDS with LAMS. The main endpoints were the incidence of overall and specific AEs. Moreover, the stent dysfunction, and reintervention rates were evaluated independently.Results: A total of 21 studies (n = 1438) were included in the final meta‐analysis. The pooled rate of technical and clinical success was 93.5% (95% confidence interval [CI]: 91.3–95.1) and 88.0% (95% CI: 83.9–91.1), respectively. After EUS‐CDS with LAMS, the pooled incidence of overall AEs was 20.1% (95% CI: 16.0–24.9). The estimated rate of early AEs was 10.6% (95% CI: 7.9–14.2), and late AEs was 11.2% (95% CI: 8.2–15.2). Infection/cholangitis was the commonest AE, with a pooled incidence of 6.1% (95% CI: 3.7–10.1). The estimated incidence of stent dysfunction and reintervention was 10.5% (95% CI: 7.5–14.4), and 12.1% (95% CI: 9.3–15.7), respectively.Conclusion: Despite with a high technical and clinical success rate, EUS‐CDS with LAMS may be associated with overall AEs and stent dysfunction in one‐fifth and one‐tenth of cases, respectively. Further efforts are required to optimize its safety and long‐term stent patency.