Yohan Park has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Yun-Su Kim
Gwangju Institute of Science and Technology
2 shared publications - Fawad
Department of Electrical Engineering and Computer Science, Gwangju Institute of Science and Technology, Gwangju, South Korea
1 shared publication Gyeong-Hun Kim
Smart Distribution Research Center, Korea Electrotechnology Research Institute (KERI), Changwon-si, South Korea
1 shared publicationH. A. Deans
U. of Houston
1 shared publication- Jeuk Kang
Gwangju Institute of Science and Technology
1 shared publication - Syed Ahson Ali Shah
Gwangju Institute of Science and Technology (GIST)
1 shared publication
Latest Publications
- 22 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 15880-15890
Machine Learning-Driven Joint Structuring of WPT Coil and Core for Enhanced Mutual Inductance and Reduced Ferrite Volume
Machine learning (ML) algorithms have shown promise in optimizing wireless power transfer (WPT) systems, particularly for electric vehicle charging and medical implants. However, most approaches focus on isolated WPT components, limiting their overall impact. This study presents an integrated optimization of WPT coil and core designs to enhance mutual inductance between transmitting (Tx) and receiving (Rx) coils. We propose a hybrid residual layer sequential neural network (HRL-SeqNet), along with SVR-based multivariate regression and deep Qnetwork (DQN) models, to enhance the WPT performance. HRL-SeqNet incorporates GRU, BiLSTM, and LSTM RNNs followed by a second-level GRU and ensemble regression to optimize the copper windings, achieving a high mutual inductance of 11.284 μH with a conventional ferrite core. Additionally, SVR and DQN models optimize the ferrite core by introducing asymmetric and symmetric vacuum configurations. The SVR-optimized asymmetric core achieved a 0.585% increase in mutual inductance while reducing ferrite volume by 24.49%. In addition, the DQN model increased mutual inductance by 1.38% and 3.16% for order 4 and order 8 rotational symmetry, respectively, with corresponding reductions in ferrite volume of 23.47% and 25.51%. These ML models show exceptional computational efficiency, with HRL-SeqNet, SVR, and DQN achieving 4,300x, 16,960x, and 10,138x speedups, respectively, over ANSYS Maxwell simulations. Experimental validations confirm the effectiveness of these ML-optimized designs, demonstrating their applicability across various WPT applications.
- 22 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 15880-15890
Machine Learning-Driven Joint Structuring of WPT Coil and Core for Enhanced Mutual Inductance and Reduced Ferrite Volume
Machine learning (ML) algorithms have shown promise in optimizing wireless power transfer (WPT) systems, particularly for electric vehicle charging and medical implants. However, most approaches focus on isolated WPT components, limiting their overall impact. This study presents an integrated optimization of WPT coil and core designs to enhance mutual inductance between transmitting (Tx) and receiving (Rx) coils. We propose a hybrid residual layer sequential neural network (HRL-SeqNet), along with SVR-based multivariate regression and deep Qnetwork (DQN) models, to enhance the WPT performance. HRL-SeqNet incorporates GRU, BiLSTM, and LSTM RNNs followed by a second-level GRU and ensemble regression to optimize the copper windings, achieving a high mutual inductance of 11.284 μH with a conventional ferrite core. Additionally, SVR and DQN models optimize the ferrite core by introducing asymmetric and symmetric vacuum configurations. The SVR-optimized asymmetric core achieved a 0.585% increase in mutual inductance while reducing ferrite volume by 24.49%. In addition, the DQN model increased mutual inductance by 1.38% and 3.16% for order 4 and order 8 rotational symmetry, respectively, with corresponding reductions in ferrite volume of 23.47% and 25.51%. These ML models show exceptional computational efficiency, with HRL-SeqNet, SVR, and DQN achieving 4,300x, 16,960x, and 10,138x speedups, respectively, over ANSYS Maxwell simulations. Experimental validations confirm the effectiveness of these ML-optimized designs, demonstrating their applicability across various WPT applications.
- Open Access
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 71924-71935
Least Absolute Value-Based Temperature-Dependent Robust State Estimation
Inaccuracies in both measurements and parameter determination can generate biased results in state estimation. The change in branch temperature precipitates fluctuations in resistance and branch flow measurements. Even when flow measurements derived from remote terminal units are precise, the erroneous resistance value can still render the estimation results inaccurate. In this paper, we propose a least absolute value based, temperature-dependent, static state estimation method. The proposed method is formulated as a linear programming, employing an L1 norm objective function and introducing a branch temperature with the expanded Jacobian to consider thermal inertia. The proposed estimator not only estimates the state but also estimates branch temperature along with the resistance. Therefore, our proposed method captures the accurate system states robust against the parameter error and measurement error. Furthermore, the proposed estimator can evaluate thermal inertia with higher accuracy compared to the existing method. The case studies illustrate the robustness of the proposed method against parameter and measurement inaccuracies. Additionally, it can estimate state and thermal inertia more effectively than the comparative estimator.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 71924-71935
Open AccessLeast Absolute Value-Based Temperature-Dependent Robust State Estimation
Inaccuracies in both measurements and parameter determination can generate biased results in state estimation. The change in branch temperature precipitates fluctuations in resistance and branch flow measurements. Even when flow measurements derived from remote terminal units are precise, the erroneous resistance value can still render the estimation results inaccurate. In this paper, we propose a least absolute value based, temperature-dependent, static state estimation method. The proposed method is formulated as a linear programming, employing an L1 norm objective function and introducing a branch temperature with the expanded Jacobian to consider thermal inertia. The proposed estimator not only estimates the state but also estimates branch temperature along with the resistance. Therefore, our proposed method captures the accurate system states robust against the parameter error and measurement error. Furthermore, the proposed estimator can evaluate thermal inertia with higher accuracy compared to the existing method. The case studies illustrate the robustness of the proposed method against parameter and measurement inaccuracies. Additionally, it can estimate state and thermal inertia more effectively than the comparative estimator.
- 1 September 1991
- Published by Society of Petroleum Engineers (SPE) in SPE Formation Evaluation
- Vol. 6 (03) , 401-408
Thermal Effects on Single-Well Chemical-Tracer Tests for Measuring Residual Oil Saturation
Summary: The single-well chemical-tracer (SWCT) test for measuring residual oil saturation, Sσr, often involves injecting cool fluid containing a reactive tracer into a warm formation. The Sor estimation with this method depends on the separation between reactant and product tracers. Because the reaction rate is temperature-dependent, accounting for the thermal effects may be necessary to obtain reliable results. Two simulator models are normally used to interpret SWCT tests. The ideal model is used for relatively homogeneous sandstone formations. The pore-diffusion model is used for heterogeneous carbonate formations. Both models have now been solved with appropriate heat-balance equations. These nonisothermal models have been used to reinterpret several previously reported field tests. For the worst case, the estimated Sor value from the nonisothermal model is 5% PV higher than that from the isothermal model. Inequality conditions have been developed that divide the parameter space of SWCT tests into two regions, depending on the location of the temperature front relative to the tracer bank during the reaction period. In the "safe" region, the estimated Sor values from isothermal and nonisothermal models are essentially equal. The inequality conditions have been extended to include the effects of over-and underburden layers and intervening shales in layered systems.
- 1 September 1991
- Published by Society of Petroleum Engineers (SPE) in SPE Formation Evaluation
- Vol. 6 (03) , 401-408
Thermal Effects on Single-Well Chemical-Tracer Tests for Measuring Residual Oil Saturation
Summary: The single-well chemical-tracer (SWCT) test for measuring residual oil saturation, Sσr, often involves injecting cool fluid containing a reactive tracer into a warm formation. The Sor estimation with this method depends on the separation between reactant and product tracers. Because the reaction rate is temperature-dependent, accounting for the thermal effects may be necessary to obtain reliable results. Two simulator models are normally used to interpret SWCT tests. The ideal model is used for relatively homogeneous sandstone formations. The pore-diffusion model is used for heterogeneous carbonate formations. Both models have now been solved with appropriate heat-balance equations. These nonisothermal models have been used to reinterpret several previously reported field tests. For the worst case, the estimated Sor value from the nonisothermal model is 5% PV higher than that from the isothermal model. Inequality conditions have been developed that divide the parameter space of SWCT tests into two regions, depending on the location of the temperature front relative to the tracer bank during the reaction period. In the "safe" region, the estimated Sor values from isothermal and nonisothermal models are essentially equal. The inequality conditions have been extended to include the effects of over-and underburden layers and intervening shales in layered systems.