L. Ropelewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
L. Ropelewski has a total of 216 co-authors. Here are the top co-authors by number of shared publications:
- Eraldo Oliveri
European Organization for Nuclear Research (CERN), 1211 Geneva 23, Switzerland
6 shared publications - Djunes Janssens
European Organization for Nuclear Research (CERN), 1211 Geneva 23, Switzerland
5 shared publications - Florian M. Brunbauer
European Organization for Nuclear Research (CERN), 1211 Geneva 23, Switzerland
5 shared publications - H. Muller
European Org Nucl Res CERN, CH-1211 Geneva 23, Switzerland
5 shared publications - K. J. Flöthner
European Organization for Nuclear Research (CERN), 1211 Geneva 23, Switzerland
5 shared publications M. van Stenis
CERN, 1211 Geneva 23, Switzerland
5 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04019
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couples a Cherenkov radiator, typically an MgF 2 crystal, to a Micromegas-based photodetector equipped with a photocathode, allowing the fast photoelectron-induced signal to suppress the intrinsic time jitter characteristic of gaseous detectors. This design enables sub-20 ps timing precision while preserving the robustness and scalability of Micro-Pattern Gaseous Detector (MPGD) technologies. The 96-pad PICOSEC-MM detector represents the latest advancement in this development, optimized for precision timing in high-energy physics. Building upon the R&D insights obtained with earlier 7-pad resistive prototypes, this large-area demonstrator was developed to validate the scalability, uniformity, and robustness of the technology for integration into the ENUBET project. The detector employs a 2.5 nm Diamond-Like Carbon (DLC) photocathode with a Micromegas board equipped with surface resistivity of 10 MΩ/□, providing an excellent timing performance. The prototype was characterized using 150 GeV/ c muons at the CERN SPS beamline, with one-third of the active area instrumented during each run. A dedicated alignment procedure, developed for multi-pad PICOSEC-MM systems, was used to reconstruct the pad centers and combine measurements across different detector regions. The measured timing resolution was 43 ps across the instrumented pads, while the Signal Arrival Time (SAT) distributions exhibited a good uniformity among the detector area that was tested. Mechanical flatness was identified as a key factor influencing timing precision. Maintaining a planarity tolerance within 10 μm is therefore critical to preserve a good timing resolution over large active areas. The successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept marking a significant step toward implementing robust, high-granularity, picosecond-level gaseous timing detectors in monitored neutrino beam experiments such as ENUBET.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04019
Open AccessDesign and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couples a Cherenkov radiator, typically an MgF 2 crystal, to a Micromegas-based photodetector equipped with a photocathode, allowing the fast photoelectron-induced signal to suppress the intrinsic time jitter characteristic of gaseous detectors. This design enables sub-20 ps timing precision while preserving the robustness and scalability of Micro-Pattern Gaseous Detector (MPGD) technologies. The 96-pad PICOSEC-MM detector represents the latest advancement in this development, optimized for precision timing in high-energy physics. Building upon the R&D insights obtained with earlier 7-pad resistive prototypes, this large-area demonstrator was developed to validate the scalability, uniformity, and robustness of the technology for integration into the ENUBET project. The detector employs a 2.5 nm Diamond-Like Carbon (DLC) photocathode with a Micromegas board equipped with surface resistivity of 10 MΩ/□, providing an excellent timing performance. The prototype was characterized using 150 GeV/ c muons at the CERN SPS beamline, with one-third of the active area instrumented during each run. A dedicated alignment procedure, developed for multi-pad PICOSEC-MM systems, was used to reconstruct the pad centers and combine measurements across different detector regions. The measured timing resolution was 43 ps across the instrumented pads, while the Signal Arrival Time (SAT) distributions exhibited a good uniformity among the detector area that was tested. Mechanical flatness was identified as a key factor influencing timing precision. Maintaining a planarity tolerance within 10 μm is therefore critical to preserve a good timing resolution over large active areas. The successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept marking a significant step toward implementing robust, high-granularity, picosecond-level gaseous timing detectors in monitored neutrino beam experiments such as ENUBET.
- Open Access
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03025
Towards MPGDs with embedded pixel ASICs
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low material budget, X-ray polarimetry at low energies (⪅ 2 keV) or rare-event searches which profit from event selection based on geometrical parameters. In this article, the idea of embedding a pixel ASIC — specifically the Timepix4 — into a micro-pattern gaseous amplification stage is illustrated. Furthermore, the first results of reading out a triple-GEM detector with the Timepix4 (GEMPix4) are shown, including the first X-ray images taken with a Timepix4 utilising Through Silicon Vias (TSVs). Lastly, a new readout concept is presented, called the `Silicon Readout Board', extending the use of pixel ASICs to read out gaseous detectors to a wider range of HEP applications.
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03025
Open AccessTowards MPGDs with embedded pixel ASICs
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low material budget, X-ray polarimetry at low energies (⪅ 2 keV) or rare-event searches which profit from event selection based on geometrical parameters. In this article, the idea of embedding a pixel ASIC — specifically the Timepix4 — into a micro-pattern gaseous amplification stage is illustrated. Furthermore, the first results of reading out a triple-GEM detector with the Timepix4 (GEMPix4) are shown, including the first X-ray images taken with a Timepix4 utilising Through Silicon Vias (TSVs). Lastly, a new readout concept is presented, called the `Silicon Readout Board', extending the use of pixel ASICs to read out gaseous detectors to a wider range of HEP applications.
- Open Access
- 11 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
- 11 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Open AccessPhotocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
- Open Access
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07027
Spatial resolution improvements with finer-pitch GEMs
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their `standard' configuration with amplification holes of 140 μm pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 μm improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.
- 1 July 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (07) , P07027
Open AccessSpatial resolution improvements with finer-pitch GEMs
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their `standard' configuration with amplification holes of 140 μm pitch in a hexagonal pattern. However, the collection of the charge cloud from the primary ionisation electrons from the drift region of the detector into the GEM holes affects the position information from the initial interacting particle. In this paper, the results from studies with a triple-GEM detector with an X-Y-strip readout anode are presented. It is demonstrated that GEMs with a finer hole pitch of here 90 μm improve the detector's spatial resolution. Within these studies, also the impact of the front-end electronics on the spatial resolution was investigated, which is briefly discussed in the paper.
- Open Access
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05053
Characterisation of resistive MPGDs with 2D readout
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A µRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05053
Open AccessCharacterisation of resistive MPGDs with 2D readout
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation results of resistive anode plane MPGDs with 2D strip readout are presented. A µRWELL prototype is investigated in view of its use as a reference tracking detector in a future gaseous beam telescope. A MicroMegas prototype with a fine-pitch mesh (730 line-pairs-per-inch) is investigated, both for comparison and to profit from the better field uniformity and thus the ability to operate the detector more stable at high gains. Furthermore, the measurements are another application of the RD51 VMM3a/SRS electronics.
- Open Access
- 1 January 2012
- Published by Oxford University Press (OUP) in Progress of Theoretical Physics Supplement
- Vol. 193, 180-183
Elastic Scattering and Total Cross-Section in p+p Reactions
Proton-proton elastic scattering has been measured by the TOTEM experiment at the CERN Large Hadron Collider at √s = 7 TeV in special runs with the Roman Pot detectors placed as close to the outgoing beam as seven times the transverse beam size. The differential cross-section measurements are reported in the |t|-range of 0.36 to 2.5 GeV2. Extending the range of data to low t values from 0.02 to 0.33 GeV2, and utilizing the luminosity measurements of CMS, the total proton-proton cross section at √s = 7 TeV is measured to be (98.3 ±0.2stat ±2.8syst) mb.
- 1 January 2012
- Published by Oxford University Press (OUP) in Progress of Theoretical Physics Supplement
- Vol. 193, 180-183
Open AccessElastic Scattering and Total Cross-Section in p+p Reactions
Proton-proton elastic scattering has been measured by the TOTEM experiment at the CERN Large Hadron Collider at √s = 7 TeV in special runs with the Roman Pot detectors placed as close to the outgoing beam as seven times the transverse beam size. The differential cross-section measurements are reported in the |t|-range of 0.36 to 2.5 GeV2. Extending the range of data to low t values from 0.02 to 0.33 GeV2, and utilizing the luminosity measurements of CMS, the total proton-proton cross section at √s = 7 TeV is measured to be (98.3 ±0.2stat ±2.8syst) mb.
- 1 January 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10915281) , 1125-1128 Vol.2
Progress in TPG construction [particle detector]
TPG is the acronym for a 3D imaging gas chamber with GEM amplification, hexaboard read-out and FADC electronics. We have constructed a TPG-head with three GEM foils (30 cm diameter) and a read-out board (30 cm diameter active surface) covered with 710000 hexagonal pads of 300 /spl mu/m size. The aligned pads are connected in parallel to one strip out of three sets of 576 parallel strips (500 /spl mu/m pitch). The three sets of strips run at 120 degrees from each other and at three different depths inside the hexaboard multi-layer structure. Each strip is read by FADC electronics. The TPG-head is under initial test in a small container with a drift volume 33 mm long and of 30 cm diameter. A 150 cm long drift volume inside a 0.7 Tesla solenoidal magnetic field has been prepared by using HARP-TPC instrumentation as a test bed.
- 1 January 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2 (10915281) , 1125-1128 Vol.2
Progress in TPG construction [particle detector]
TPG is the acronym for a 3D imaging gas chamber with GEM amplification, hexaboard read-out and FADC electronics. We have constructed a TPG-head with three GEM foils (30 cm diameter) and a read-out board (30 cm diameter active surface) covered with 710000 hexagonal pads of 300 /spl mu/m size. The aligned pads are connected in parallel to one strip out of three sets of 576 parallel strips (500 /spl mu/m pitch). The three sets of strips run at 120 degrees from each other and at three different depths inside the hexaboard multi-layer structure. Each strip is read by FADC electronics. The TPG-head is under initial test in a small container with a drift volume 33 mm long and of 30 cm diameter. A 150 cm long drift volume inside a 0.7 Tesla solenoidal magnetic field has been prepared by using HARP-TPC instrumentation as a test bed.
- 1 August 1999
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 433 (1-2) , 464-470
Recent progress in GEM manufacturing and operation
- 1 August 1999
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 433 (1-2) , 464-470
Recent progress in GEM manufacturing and operation