Chung-Yang Sue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chung-Yang Sue has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Yu-Jen Wang
Department of Mechanical and Electromechanical Engineering, National Sun Yat-sen University, Kaohsiung, Taiwan
2 shared publications - Chia-Hsien Chen
Department of Mechanical and Electromechanical Engineering, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan
1 shared publication Chih-Che Lin
Smart Microsystems Technology Center, Industrial Technology Research Institute
1 shared publicationChih-Hsiou Lin
Microsystems Technology Center, Industrial Technology Research Institute, Tainan City, Taiwan
1 shared publication- Chih-Hsiou Lin
Microsystems Technology Center, Industrial Technology Research Institute, Tainan 709, Taiwan
1 shared publication Ching-Wei Hsu
National Sun Yat-Sen University
1 shared publication
Latest Publications
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 2858-2866
Novel Sensory Tool Holder Design and Optimization for Multiaxis Cutting Force Sensing in Manufacturing
Multiaxis cutting force sensors enable smart process control and tool condition monitoring in manufacturing; they allow the detection of workpiece damage and suboptimal surface finish, which can arise from tool wear. Existing methods require complex structure modifications to enhance sensor sensitivity, leading to weakened processing performance and expensive customization costs. This article describes the mechanical design and optimization of a sensory tool holder with embedded piezoelectric sensors in standard tool holders. The design has an almost identical rigidity to that of a regular tool holder. We developed a high-fidelity sensing model by multiaxis piezoelectricity and stress analysis, and optimize the sensor locations and orientations to achieve high sensitivity, accuracy, and cross-axis decoupling in specific directions. Static tests indicated that under optimized parameter configurations, the designed tool holder achieved a maximum cross-coupling error of approximately 4.6%, only half of existing researches; it also demonstrated better performance in sensitivity, linearity, hysteresis, and repeatability. The proposed optimal design was verified by the high fidelity model to have a maximum sensitivity error of only 5.34%, confirming its applicability for sensor embedding optimization in various types of standard tool holders without requiring structure modification.
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 2858-2866
Novel Sensory Tool Holder Design and Optimization for Multiaxis Cutting Force Sensing in Manufacturing
Multiaxis cutting force sensors enable smart process control and tool condition monitoring in manufacturing; they allow the detection of workpiece damage and suboptimal surface finish, which can arise from tool wear. Existing methods require complex structure modifications to enhance sensor sensitivity, leading to weakened processing performance and expensive customization costs. This article describes the mechanical design and optimization of a sensory tool holder with embedded piezoelectric sensors in standard tool holders. The design has an almost identical rigidity to that of a regular tool holder. We developed a high-fidelity sensing model by multiaxis piezoelectricity and stress analysis, and optimize the sensor locations and orientations to achieve high sensitivity, accuracy, and cross-axis decoupling in specific directions. Static tests indicated that under optimized parameter configurations, the designed tool holder achieved a maximum cross-coupling error of approximately 4.6%, only half of existing researches; it also demonstrated better performance in sensitivity, linearity, hysteresis, and repeatability. The proposed optimal design was verified by the high fidelity model to have a maximum sensitivity error of only 5.34%, confirming its applicability for sensor embedding optimization in various types of standard tool holders without requiring structure modification.
- 27 September 2019
- Published by Springer Nature
- p. 244-251
Based on a Calibration Machine and Process to Develop a Six-Axis Force/Torque Sensor
- 27 September 2019
- Published by Springer Nature
- p. 244-251
Based on a Calibration Machine and Process to Develop a Six-Axis Force/Torque Sensor
- Open Access
- 29 October 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (11) , 556
Estimation of Blood Pressure in the Radial Artery Using Strain-Based Pulse Wave and Photoplethysmography Sensors
Blood pressure (BP) is a crucial indicator of cardiac health and vascular status. This study explores the relationship between radial artery BP and wrist skin strain. A BP estimation method based on the physical model of wrist skin tissues and pulse wave velocity (PWV) is proposed. A photoplethysmography (PPG) sensor and strain gauge are used in this method. The developed strain-based pulse wave sensor consists of a pressing force sensor, which ensures consistent pressing force, and a strain gauge, which measures the cardiac pulsation on the wrist skin. These features enable long-term BP monitoring without incurring the limb compression caused by a cuff. Thus, this method is useful for individuals requiring continuous BP monitoring. In this study, the BP of each participant was measured in three modes (before, during, and after exercise), and the data were compared using a clinically validated sphygmomanometer. The percentage errors of diastolic and systolic BP readings were, respectively, 4.74% and 4.49% before exercise, 6.38% and 6.10% during exercise, and 5.98% and 4.81% after a rest. The errors were compared with a clinically validated sphygmomanometer.
- 29 October 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (11) , 556
Open AccessEstimation of Blood Pressure in the Radial Artery Using Strain-Based Pulse Wave and Photoplethysmography Sensors
Blood pressure (BP) is a crucial indicator of cardiac health and vascular status. This study explores the relationship between radial artery BP and wrist skin strain. A BP estimation method based on the physical model of wrist skin tissues and pulse wave velocity (PWV) is proposed. A photoplethysmography (PPG) sensor and strain gauge are used in this method. The developed strain-based pulse wave sensor consists of a pressing force sensor, which ensures consistent pressing force, and a strain gauge, which measures the cardiac pulsation on the wrist skin. These features enable long-term BP monitoring without incurring the limb compression caused by a cuff. Thus, this method is useful for individuals requiring continuous BP monitoring. In this study, the BP of each participant was measured in three modes (before, during, and after exercise), and the data were compared using a clinically validated sphygmomanometer. The percentage errors of diastolic and systolic BP readings were, respectively, 4.74% and 4.49% before exercise, 6.38% and 6.10% during exercise, and 5.98% and 4.81% after a rest. The errors were compared with a clinically validated sphygmomanometer.
- Open Access
An Integrated Thermal Compensation System for MEMS Inertial Sensors
An active thermal compensation system for a low temperature-bias-drift (TBD) MEMS-based gyroscope is proposed in this study. First, a micro-gyroscope is fabricated by a high-aspect-ratio silicon-on-glass (SOG) process and vacuum packaged by glass frit bonding. Moreover, a drive/readout ASIC, implemented by the 0.25 µm 1P5M standard CMOS process, is designed and integrated with the gyroscope by directly wire bonding. Then, since the temperature effect is one of the critical issues in the high performance gyroscope applications, the temperature-dependent characteristics of the micro-gyroscope are discussed. Furthermore, to compensate the TBD of the micro-gyroscope, a thermal compensation system is proposed and integrated in the aforementioned ASIC to actively tune the parameters in the digital trimming mechanism, which is designed in the readout ASIC. Finally, some experimental results demonstrate that the TBD of the micro-gyroscope can be compensated effectively by the proposed compensation system.
Open AccessAn Integrated Thermal Compensation System for MEMS Inertial Sensors
An active thermal compensation system for a low temperature-bias-drift (TBD) MEMS-based gyroscope is proposed in this study. First, a micro-gyroscope is fabricated by a high-aspect-ratio silicon-on-glass (SOG) process and vacuum packaged by glass frit bonding. Moreover, a drive/readout ASIC, implemented by the 0.25 µm 1P5M standard CMOS process, is designed and integrated with the gyroscope by directly wire bonding. Then, since the temperature effect is one of the critical issues in the high performance gyroscope applications, the temperature-dependent characteristics of the micro-gyroscope are discussed. Furthermore, to compensate the TBD of the micro-gyroscope, a thermal compensation system is proposed and integrated in the aforementioned ASIC to actively tune the parameters in the digital trimming mechanism, which is designed in the readout ASIC. Finally, some experimental results demonstrate that the TBD of the micro-gyroscope can be compensated effectively by the proposed compensation system.
- 30 November 2013
- Published by Springer Nature in Microsystem Technologies
- Vol. 20 (12) , 2173-2184
Dual-axis tuning fork vibratory gyroscope with anti-phase mode vibration mechanism
- 30 November 2013
- Published by Springer Nature in Microsystem Technologies
- Vol. 20 (12) , 2173-2184
Dual-axis tuning fork vibratory gyroscope with anti-phase mode vibration mechanism