Pariwat Taweekitikul
Pariwat Taweekitikul has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Abdul Azeez Abdu Aliyu
Affiliation M3D Laboratory, Advanced Materials Analysis Research Unit, Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
3 shared publicationsChedtha Puncreobutr
Affiliations M3D Laboratory, Advanced Materials Analysis Research Unit, Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand, Biomedical Engineering Research Center, Chulalongkorn University, Bangkok, Thailand
3 shared publicationsBoonrat Lohwongwatana
Affiliations M3D Laboratory, Advanced Materials Analysis Research Unit, Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand, Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand, Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, United States of America
2 shared publications- Chinnapat Panwisawas
School of Engineering and Materials Science, Queen Mary University of London, London E1 4NS, United Kingdom
2 shared publications - Junji Shinjo
Shimane University
2 shared publications - Saran Tantavisut
Hip Fracture Research Unit, Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Springer Nature in Scientific Reports
Effect of derotation boot versus skin traction on pain in patients with intertrochanteric fractures a randomized controlled trial
Intertrochanteric hip fractures in older adults are often associated with severe pain, and inadequate preoperative analgesia increases the risk of delirium, immobility, and mortality. Although skin traction (ST) is widely used for temporary stabilization, its analgesic effectiveness remains poorly supported, and it may cause discomfort in frail patients. The derotation boot (DB) has emerged as a promising alternative, but its clinical value remains unclear due to limited comparative data. The primary objective of this study was to determine whether the DB provides non-inferior preoperative pain relief compared to ST. Secondary objectives included evaluating morphine consumption, patient comfort, delirium incidence, perioperative complications, operative time, and blood loss. This multicenter, non-inferiority randomized controlled trial was conducted across two Level I and one Level II trauma centers. Patients aged ≥ 60 years with acute intertrochanteric fractures were randomized to receive either DB or ST. Pain was assessed using the Visual Analog Scale (VAS) at 1 h, 24 h, and immediately before surgery. Secondary outcomes included total morphine use, comfort (measured by the Immobilization Comfort Questionnaire), delirium, intraoperative blood loss, complications, and surgical duration. Ninety-seven patients were enrolled (DB: 48; ST: 49), with a mean age of 80.8 ± 10.2 years in the DB group and 78.3 ± 9.4 years in the ST group. DB was non-inferior to ST for pain control at 1 h (VAS 4.6 vs. 5.7; β = −1.464; p < 0.001) and 24 h (1.9 vs. 2.7; β = −1.048; p = 0.006), with no significant difference immediately before surgery (p = 0.657). Comfort was significantly higher with DB (82.0 vs. 76.8; p = 0.0015). Other outcomes showed no significant group differences. The derotation boot demonstrated non-inferior pain control compared with skin traction at 1 h, 24 h, and immediately before surgery, with improved early comfort. Superiority of the derotation boot was not demonstrated at the final preoperative assessment. Trial Registration : Thai Clinical Trials Registry (ID: TCTR20230908004) from 01.02.2023.
- 30 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessEffect of derotation boot versus skin traction on pain in patients with intertrochanteric fractures a randomized controlled trial
Intertrochanteric hip fractures in older adults are often associated with severe pain, and inadequate preoperative analgesia increases the risk of delirium, immobility, and mortality. Although skin traction (ST) is widely used for temporary stabilization, its analgesic effectiveness remains poorly supported, and it may cause discomfort in frail patients. The derotation boot (DB) has emerged as a promising alternative, but its clinical value remains unclear due to limited comparative data. The primary objective of this study was to determine whether the DB provides non-inferior preoperative pain relief compared to ST. Secondary objectives included evaluating morphine consumption, patient comfort, delirium incidence, perioperative complications, operative time, and blood loss. This multicenter, non-inferiority randomized controlled trial was conducted across two Level I and one Level II trauma centers. Patients aged ≥ 60 years with acute intertrochanteric fractures were randomized to receive either DB or ST. Pain was assessed using the Visual Analog Scale (VAS) at 1 h, 24 h, and immediately before surgery. Secondary outcomes included total morphine use, comfort (measured by the Immobilization Comfort Questionnaire), delirium, intraoperative blood loss, complications, and surgical duration. Ninety-seven patients were enrolled (DB: 48; ST: 49), with a mean age of 80.8 ± 10.2 years in the DB group and 78.3 ± 9.4 years in the ST group. DB was non-inferior to ST for pain control at 1 h (VAS 4.6 vs. 5.7; β = −1.464; p < 0.001) and 24 h (1.9 vs. 2.7; β = −1.048; p = 0.006), with no significant difference immediately before surgery (p = 0.657). Comfort was significantly higher with DB (82.0 vs. 76.8; p = 0.0015). Other outcomes showed no significant group differences. The derotation boot demonstrated non-inferior pain control compared with skin traction at 1 h, 24 h, and immediately before surgery, with improved early comfort. Superiority of the derotation boot was not demonstrated at the final preoperative assessment. Trial Registration : Thai Clinical Trials Registry (ID: TCTR20230908004) from 01.02.2023.
- Open Access
- 23 September 2026
- Published by Elsevier in SSRN Electronic Journal
Radiographic predictors of early secondary displacement to operative threshold in nonoperatively treated scapular fractures
BackgroundCurrent radiographic criteria for operative treatment of scapular fractures define fracture deformity at presentation but do not identify fractures at risk of subsequent displacement. We sought to determine which initial radiographic features predict progression to established operative thresholds during nonoperative treatment.MethodsWe reviewed 114 consecutive extra-articular scapular body or neck fractures initially treated nonoperatively, none of which met Cole operative criteria on the initial injury radiograph. Two blinded observers measured glenopolar angle, medialisation, sagittal angulation, sagittal translation and medial border displacement on the initial injury and follow-up radiographs. Follow-up radiographs obtained one to four weeks after injury were assessed for progression to any Cole radiographic operative criterion. Predictors were evaluated using Firth's penalized maximum likelihood.ResultsTwenty-five patients (21.9%) progressed to at least one radiographic operative criterion, 23 through medialisation. On multivariable analysis, initial medialisation of 15 mm or more (adjusted odds ratio 52.84, 95% CI 8.23–339.44) and sagittal translation of 10 mm or more (5.97, 1.23–28.84) were independently associated with progression. Initial medialisation discriminated best but correlated much more strongly with follow-up medialisation (rho = 0.89) than with the amount of interval displacement (rho = 0.14), indicating proximity to the operative threshold rather than intrinsic instability.ConclusionApproximately one in five fractures initially selected for nonoperative treatment progressed to a radiographic operative threshold within four weeks. Sagittal translation of 10 mm or more, or medial border displacement of 4 mm or more, was present in almost all fractures that progressed; fractures with neither feature progressed in only 2.6% of cases. These findings may help identify a low-risk subgroup suitable for less intensive radiographic surveillance, but the candidate thresholds and exploratory multivariable model require external validation.
- 23 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRadiographic predictors of early secondary displacement to operative threshold in nonoperatively treated scapular fractures
BackgroundCurrent radiographic criteria for operative treatment of scapular fractures define fracture deformity at presentation but do not identify fractures at risk of subsequent displacement. We sought to determine which initial radiographic features predict progression to established operative thresholds during nonoperative treatment.MethodsWe reviewed 114 consecutive extra-articular scapular body or neck fractures initially treated nonoperatively, none of which met Cole operative criteria on the initial injury radiograph. Two blinded observers measured glenopolar angle, medialisation, sagittal angulation, sagittal translation and medial border displacement on the initial injury and follow-up radiographs. Follow-up radiographs obtained one to four weeks after injury were assessed for progression to any Cole radiographic operative criterion. Predictors were evaluated using Firth's penalized maximum likelihood.ResultsTwenty-five patients (21.9%) progressed to at least one radiographic operative criterion, 23 through medialisation. On multivariable analysis, initial medialisation of 15 mm or more (adjusted odds ratio 52.84, 95% CI 8.23–339.44) and sagittal translation of 10 mm or more (5.97, 1.23–28.84) were independently associated with progression. Initial medialisation discriminated best but correlated much more strongly with follow-up medialisation (rho = 0.89) than with the amount of interval displacement (rho = 0.14), indicating proximity to the operative threshold rather than intrinsic instability.ConclusionApproximately one in five fractures initially selected for nonoperative treatment progressed to a radiographic operative threshold within four weeks. Sagittal translation of 10 mm or more, or medial border displacement of 4 mm or more, was present in almost all fractures that progressed; fractures with neither feature progressed in only 2.6% of cases. These findings may help identify a low-risk subgroup suitable for less intensive radiographic surveillance, but the candidate thresholds and exploratory multivariable model require external validation.
- Open Access
- 26 December 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (12) , e0339618
Biocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants
Implant-associated infections (IAI) are a significant concern within the field of orthopedics. To develop an implant with antimicrobial properties, titania nanotubes (TNTs) supported with iodine were synthesized on 3D-printed Ti-6Al-4V implants using the electrochemical anodization (ECA) technique. This study aims to analyze the release profile of iodine and the antimicrobial efficacy and cytotoxicity of the iodine-supported TNT (I-TNTs) on the 3D-printed Ti-6Al-4V implant. 3D-printed Ti-6Al-4V samples were doped with six different iodine formulations, including four test groups containing TNT and two control groups without TNT. As printed 3D Ti-6Al-4V samples and TNTs samples without iodine were also utilized as control groups. In vitro assays were performed to assess the drug elution, cytotoxicity, and antimicrobial efficacy. All tested I-TNTs samples exhibited sustained iodine release over 28 days without an initial burst. Notably, the amount of iodine released from I-TNTs was significantly higher compared to the control group. TNTs with a higher aspect ratio (AR) and the ECA process using higher potassium iodide (KI) concentration were found to have better cumulative iodine release profiles. No cytotoxicity was observed when tested against the mouse calvaria-derived preosteoblast cell line (MC3T3-E1). The antibacterial property of the implant surface became evident within 24 hours, with complete inhibition of S. aureus and MRSA in I-TNTs samples. This innovative approach is an intriguing alternative for preventing infections on 3D-printed Ti-6Al-4V implants.
- 26 December 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (12) , e0339618
Open AccessBiocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants
Implant-associated infections (IAI) are a significant concern within the field of orthopedics. To develop an implant with antimicrobial properties, titania nanotubes (TNTs) supported with iodine were synthesized on 3D-printed Ti-6Al-4V implants using the electrochemical anodization (ECA) technique. This study aims to analyze the release profile of iodine and the antimicrobial efficacy and cytotoxicity of the iodine-supported TNT (I-TNTs) on the 3D-printed Ti-6Al-4V implant. 3D-printed Ti-6Al-4V samples were doped with six different iodine formulations, including four test groups containing TNT and two control groups without TNT. As printed 3D Ti-6Al-4V samples and TNTs samples without iodine were also utilized as control groups. In vitro assays were performed to assess the drug elution, cytotoxicity, and antimicrobial efficacy. All tested I-TNTs samples exhibited sustained iodine release over 28 days without an initial burst. Notably, the amount of iodine released from I-TNTs was significantly higher compared to the control group. TNTs with a higher aspect ratio (AR) and the ECA process using higher potassium iodide (KI) concentration were found to have better cumulative iodine release profiles. No cytotoxicity was observed when tested against the mouse calvaria-derived preosteoblast cell line (MC3T3-E1). The antibacterial property of the implant surface became evident within 24 hours, with complete inhibition of S. aureus and MRSA in I-TNTs samples. This innovative approach is an intriguing alternative for preventing infections on 3D-printed Ti-6Al-4V implants.
- 22 November 2024
- Published by Elsevier in Engineering Failure Analysis
- Vol. 168
Lack of fusion-induced cracking effect on tensile and fatigue behaviours of laser powder-bed fusion-processed Ti-6Al-4V implant
- 22 November 2024
- Published by Elsevier in Engineering Failure Analysis
- Vol. 168
Lack of fusion-induced cracking effect on tensile and fatigue behaviours of laser powder-bed fusion-processed Ti-6Al-4V implant
- Open Access
- 27 April 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 30, 5121-5132
Laser-inherent porosity defects in additively manufactured Ti–6Al–4V implant: Formation, distribution, and effect on fatigue performance
- 27 April 2024
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 30, 5121-5132
Open AccessLaser-inherent porosity defects in additively manufactured Ti–6Al–4V implant: Formation, distribution, and effect on fatigue performance