PTPariwat Taweekitikul

Pariwat Taweekitikul

*This is an algorithmically generated author record based on publicly available information.

Pariwat Taweekitikul has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Abdul Azeez Abdu Aliyu

    Affiliation M3D Laboratory, Advanced Materials Analysis Research Unit, Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand

    3 shared publications
  • Chedtha Puncreobutr

    Affiliations M3D Laboratory, Advanced Materials Analysis Research Unit, Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand, Biomedical Engineering Research Center, Chulalongkorn University, Bangkok, Thailand

    3 shared publications
  • Boonrat Lohwongwatana

    Affiliations M3D Laboratory, Advanced Materials Analysis Research Unit, Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand, Department of Metallurgical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand, Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts, United States of America

    2 shared publications
  • Chinnapat Panwisawas

    School of Engineering and Materials Science, Queen Mary University of London, London E1 4NS, United Kingdom

    2 shared publications
  • Junji Shinjo

    Shimane University

    2 shared publications
  • Saran Tantavisut

    Hip Fracture Research Unit, Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand

    2 shared publications

Latest Publications

  • Open Access

    Effect of derotation boot versus skin traction on pain in patients with intertrochanteric fractures a randomized controlled trial

    by Sanzhar Artykbay, Saran Tantavisut, Chavarin Amarase, Pariwat Taweekitikul, Techit Leelasestaporn, Supacheep Viriyakorkitkul

    Intertrochanteric hip fractures in older adults are often associated with severe pain, and inadequate preoperative analgesia increases the risk of delirium, immobility, and mortality. Although skin traction (ST) is widely used for temporary stabilization, its analgesic effectiveness remains poorly supported, and it may cause discomfort in frail patients. The derotation boot (DB) has emerged as a promising alternative, but its clinical value remains unclear due to limited comparative data. The primary objective of this study was to determine whether the DB provides non-inferior preoperative pain relief compared to ST. Secondary objectives included evaluating morphine consumption, patient comfort, delirium incidence, perioperative complications, operative time, and blood loss. This multicenter, non-inferiority randomized controlled trial was conducted across two Level I and one Level II trauma centers. Patients aged ≥ 60 years with acute intertrochanteric fractures were randomized to receive either DB or ST. Pain was assessed using the Visual Analog Scale (VAS) at 1 h, 24 h, and immediately before surgery. Secondary outcomes included total morphine use, comfort (measured by the Immobilization Comfort Questionnaire), delirium, intraoperative blood loss, complications, and surgical duration. Ninety-seven patients were enrolled (DB: 48; ST: 49), with a mean age of 80.8 ± 10.2 years in the DB group and 78.3 ± 9.4 years in the ST group. DB was non-inferior to ST for pain control at 1 h (VAS 4.6 vs. 5.7; β = −1.464; p < 0.001) and 24 h (1.9 vs. 2.7; β = −1.048; p = 0.006), with no significant difference immediately before surgery (p = 0.657). Comfort was significantly higher with DB (82.0 vs. 76.8; p = 0.0015). Other outcomes showed no significant group differences. The derotation boot demonstrated non-inferior pain control compared with skin traction at 1 h, 24 h, and immediately before surgery, with improved early comfort. Superiority of the derotation boot was not demonstrated at the final preoperative assessment. Trial Registration : Thai Clinical Trials Registry (ID: TCTR20230908004) from 01.02.2023.

  • Open Access

    Radiographic predictors of early secondary displacement to operative threshold in nonoperatively treated scapular fractures

    by Chittawee Jiamton, Wachagorn Kompongpapah, Napat Ayarangsaritkul, Techit Leelasestaporn, Pariwat Taweekitikul, Piyabuth Kittithamvongs, Thongchai Laohathaimongkol, Theerachai Apivatthakakul

    BackgroundCurrent radiographic criteria for operative treatment of scapular fractures define fracture deformity at presentation but do not identify fractures at risk of subsequent displacement. We sought to determine which initial radiographic features predict progression to established operative thresholds during nonoperative treatment.MethodsWe reviewed 114 consecutive extra-articular scapular body or neck fractures initially treated nonoperatively, none of which met Cole operative criteria on the initial injury radiograph. Two blinded observers measured glenopolar angle, medialisation, sagittal angulation, sagittal translation and medial border displacement on the initial injury and follow-up radiographs. Follow-up radiographs obtained one to four weeks after injury were assessed for progression to any Cole radiographic operative criterion. Predictors were evaluated using Firth's penalized maximum likelihood.ResultsTwenty-five patients (21.9%) progressed to at least one radiographic operative criterion, 23 through medialisation. On multivariable analysis, initial medialisation of 15 mm or more (adjusted odds ratio 52.84, 95% CI 8.23–339.44) and sagittal translation of 10 mm or more (5.97, 1.23–28.84) were independently associated with progression. Initial medialisation discriminated best but correlated much more strongly with follow-up medialisation (rho = 0.89) than with the amount of interval displacement (rho = 0.14), indicating proximity to the operative threshold rather than intrinsic instability.ConclusionApproximately one in five fractures initially selected for nonoperative treatment progressed to a radiographic operative threshold within four weeks. Sagittal translation of 10 mm or more, or medial border displacement of 4 mm or more, was present in almost all fractures that progressed; fractures with neither feature progressed in only 2.6% of cases. These findings may help identify a low-risk subgroup suitable for less intensive radiographic surveillance, but the candidate thresholds and exploratory multivariable model require external validation.

  • Open Access

    Biocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants

    by Pariwat Taweekitikul, Abdul Azeez Abdu Aliyu, Nanthawan Jinakul, Amaraporn Wongrakpanich, Chedtha Puncreobutr, Jirapon Khamwannah, Boonrat Lohwongwatana, Saran Tantavisut

    Implant-associated infections (IAI) are a significant concern within the field of orthopedics. To develop an implant with antimicrobial properties, titania nanotubes (TNTs) supported with iodine were synthesized on 3D-printed Ti-6Al-4V implants using the electrochemical anodization (ECA) technique. This study aims to analyze the release profile of iodine and the antimicrobial efficacy and cytotoxicity of the iodine-supported TNT (I-TNTs) on the 3D-printed Ti-6Al-4V implant. 3D-printed Ti-6Al-4V samples were doped with six different iodine formulations, including four test groups containing TNT and two control groups without TNT. As printed 3D Ti-6Al-4V samples and TNTs samples without iodine were also utilized as control groups. In vitro assays were performed to assess the drug elution, cytotoxicity, and antimicrobial efficacy. All tested I-TNTs samples exhibited sustained iodine release over 28 days without an initial burst. Notably, the amount of iodine released from I-TNTs was significantly higher compared to the control group. TNTs with a higher aspect ratio (AR) and the ECA process using higher potassium iodide (KI) concentration were found to have better cumulative iodine release profiles. No cytotoxicity was observed when tested against the mouse calvaria-derived preosteoblast cell line (MC3T3-E1). The antibacterial property of the implant surface became evident within 24 hours, with complete inhibition of S. aureus and MRSA in I-TNTs samples. This innovative approach is an intriguing alternative for preventing infections on 3D-printed Ti-6Al-4V implants.

  • Lack of fusion-induced cracking effect on tensile and fatigue behaviours of laser powder-bed fusion-processed Ti-6Al-4V implant

    by Abdul Azeez Abdu Aliyu, Chedtha Puncreobutr, Junji Shinjo, Surasak Kuimalee, Thanawat Phetrattanarangsi, Thanachai Boonchuduang, Pariwat Taweekitikul, Chinnapat Panwisawas, Wanming Li, Kitti Poungsiri, et al.


  • Open Access

    Laser-inherent porosity defects in additively manufactured Ti–6Al–4V implant: Formation, distribution, and effect on fatigue performance

    by Abdul Azeez Abdu Aliyu, Chedtha Puncreobutr, Surasak Kuimalee, Thanawat Phetrattanarangsi, Thanachai Boonchuduang, Pariwat Taweekitikul, Chinnapat Panwisawas, Junji Shinjo, Boonrat Lohwongwatana