Floriano Torres Neto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Floriano Torres Neto has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- André Gifalli
School of Engineering, São Paulo State University (Unesp), Bauru 17033-360, SP, Brazil
3 shared publications - André Nunes de Souza
School of Engineering, São Paulo State University (Unesp), Bauru 17033-360, SP, Brazil
3 shared publications - Alfredo Bonini Neto
School of Sciences and Engineering, São Paulo State University (UNESP), Tupã 17602-496, Brazil
2 shared publications - Marco Akio Ikeshoji
Federal Institute of Education, Science and Technology (IFSP), Birigui 16201-407, SP, Brazil
2 shared publications - André von Frühauf Hublard
School of Engineering, São Paulo State University (Unesp), Bauru 17033-360, SP, Brazil
1 shared publication - Danilo Sinkiti Gastaldello
Faculty of Engineering, University of Marilia (UNIMAR), Marília 17525-902, SP, Brazil
1 shared publication
Latest Publications
- Open Access
- 18 September 2025
- Published by MDPI AG in Machine Learning and Knowledge Extraction
- Vol. 7 (3) , 102
Exploiting the Feature Space Structures of KNN and OPF Algorithms for Identification of Incipient Faults in Power Transformers
Power transformers represent critical assets within the electrical power system, and their unexpected failures may result in substantial financial losses for both utilities and consumers. Dissolved Gas Analysis (DGA) is a well-established diagnostic method extensively employed to detect incipient faults in power transformers. Although several conventional and machine learning techniques have been applied to DGA, most of them focus only on fault classification and lack the capability to provide predictive scenarios that would enable proactive maintenance planning. In this context, the present study introduces a novel approach to DGA interpretation, which highlights the trends and progression of faults by exploring the feature space through the algorithms k-Nearest Neighbors (KNN) and Optimum-Path Forest (OPF). To improve accuracy, the following strategies were implemented: statistical filtering based on normal distribution to eliminate outliers from the dataset; augmentation of gas-related features; and feature selection using optimization algorithms such as Cuckoo Search and Genetic Algorithms. The approach was validated using data from several transformers, with fault diagnoses cross-checked against inspection reports provided by the utility company. The findings indicate that the proposed method offers valuable insights into the progression, proximity, and classification of faults with satisfactory accuracy, thereby supporting its recommendation as a complementary tool for diagnosing incipient transformer faults.
- 18 September 2025
- Published by MDPI AG in Machine Learning and Knowledge Extraction
- Vol. 7 (3) , 102
Open AccessExploiting the Feature Space Structures of KNN and OPF Algorithms for Identification of Incipient Faults in Power Transformers
Power transformers represent critical assets within the electrical power system, and their unexpected failures may result in substantial financial losses for both utilities and consumers. Dissolved Gas Analysis (DGA) is a well-established diagnostic method extensively employed to detect incipient faults in power transformers. Although several conventional and machine learning techniques have been applied to DGA, most of them focus only on fault classification and lack the capability to provide predictive scenarios that would enable proactive maintenance planning. In this context, the present study introduces a novel approach to DGA interpretation, which highlights the trends and progression of faults by exploring the feature space through the algorithms k-Nearest Neighbors (KNN) and Optimum-Path Forest (OPF). To improve accuracy, the following strategies were implemented: statistical filtering based on normal distribution to eliminate outliers from the dataset; augmentation of gas-related features; and feature selection using optimization algorithms such as Cuckoo Search and Genetic Algorithms. The approach was validated using data from several transformers, with fault diagnoses cross-checked against inspection reports provided by the utility company. The findings indicate that the proposed method offers valuable insights into the progression, proximity, and classification of faults with satisfactory accuracy, thereby supporting its recommendation as a complementary tool for diagnosing incipient transformer faults.
- Open Access
- 18 October 2024
- Published by MDPI AG in Applied System Innovation
- Vol. 7 (5) , 100
Forecasting Electricity Consumption Using Function Fitting Artificial Neural Networks and Regression Methods
With the growth of smart grids, consumers now have access to new technologies that enable improvements in the quality of service provided and allow new levels of energy efficiency. Much of this increase in energy efficiency is directly related to changes in consumption habits due to the quantity and quality of information made available by new technologies. At this point, short-term consumption forecasting can be considered an effective information tool in the search for better consumption patterns and energy efficiency. This paper presents prediction tests combining the result obtained from an artificial neural network and regression methods. The artificial neural network used was the Multilayer Perceptron (MLP), and its results were compared with polynomial regression techniques (first, second, and third degree), demonstrating the superiority of the network. The neural network has proven to be a highly effective tool for forecasting future data, demonstrating its ability to capture complex patterns in input data and produce accurate estimates. Additionally, the flexibility of neural networks in handling large volumes of data and their continuous adjustment capability further enhance their suitability as a robust tool for future predictions. The results corroborate the capacity of the methodology presented for short-term consumption forecasting.
- 18 October 2024
- Published by MDPI AG in Applied System Innovation
- Vol. 7 (5) , 100
Open AccessForecasting Electricity Consumption Using Function Fitting Artificial Neural Networks and Regression Methods
With the growth of smart grids, consumers now have access to new technologies that enable improvements in the quality of service provided and allow new levels of energy efficiency. Much of this increase in energy efficiency is directly related to changes in consumption habits due to the quantity and quality of information made available by new technologies. At this point, short-term consumption forecasting can be considered an effective information tool in the search for better consumption patterns and energy efficiency. This paper presents prediction tests combining the result obtained from an artificial neural network and regression methods. The artificial neural network used was the Multilayer Perceptron (MLP), and its results were compared with polynomial regression techniques (first, second, and third degree), demonstrating the superiority of the network. The neural network has proven to be a highly effective tool for forecasting future data, demonstrating its ability to capture complex patterns in input data and produce accurate estimates. Additionally, the flexibility of neural networks in handling large volumes of data and their continuous adjustment capability further enhance their suitability as a robust tool for future predictions. The results corroborate the capacity of the methodology presented for short-term consumption forecasting.
- Open Access
- 24 May 2024
- Published by MDPI AG in Applied System Innovation
- Vol. 7 (3) , 41
Fault Detection and Normal Operating Condition in Power Transformers via Pattern Recognition Artificial Neural Network
Aging, degradation, or damage to internal insulation materials often contribute to transformer failures. Furthermore, combustible gases can be produced when these insulation materials experience thermal or electrical stresses. This paper presents an artificial neural network for pattern recognition (PRN) to classify the operating conditions of power transformers (normal, thermal faults, and electrical faults) depending on the combustible gases present in them. Two network configurations were presented, one with five and the other with ten neurons in the hidden layer. The main advantage of applying this model through artificial neural networks is its ability to capture the nonlinear characteristics of the samples under study, thus avoiding the need for iterative procedures. The effectiveness and applicability of the proposed methodology were evaluated on 815 real data samples. Based on the results, the PRN performed well in both training and validation (for samples that were not part of the training), with a mean squared error (MSE) close to expected (0.001). The network was able to classify the samples with a 98% accuracy rate of the 815 samples presented and with 100% accuracy in validation, showing that the methodology developed is capable of acting as a tool for diagnosing the operability of power transformers.
- 24 May 2024
- Published by MDPI AG in Applied System Innovation
- Vol. 7 (3) , 41
Open AccessFault Detection and Normal Operating Condition in Power Transformers via Pattern Recognition Artificial Neural Network
Aging, degradation, or damage to internal insulation materials often contribute to transformer failures. Furthermore, combustible gases can be produced when these insulation materials experience thermal or electrical stresses. This paper presents an artificial neural network for pattern recognition (PRN) to classify the operating conditions of power transformers (normal, thermal faults, and electrical faults) depending on the combustible gases present in them. Two network configurations were presented, one with five and the other with ten neurons in the hidden layer. The main advantage of applying this model through artificial neural networks is its ability to capture the nonlinear characteristics of the samples under study, thus avoiding the need for iterative procedures. The effectiveness and applicability of the proposed methodology were evaluated on 815 real data samples. Based on the results, the PRN performed well in both training and validation (for samples that were not part of the training), with a mean squared error (MSE) close to expected (0.001). The network was able to classify the samples with a 98% accuracy rate of the 815 samples presented and with 100% accuracy in validation, showing that the methodology developed is capable of acting as a tool for diagnosing the operability of power transformers.