Kenji Tobita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenji Tobita has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Takahashi
Tohoku University
4 shared publications - Tetsutarou Oishi
Tohoku University
3 shared publications K. Yoshimura
Department of Quantum Science and Energy Engineering, Tohoku University , 6-6-01-2 Aobayama, Sendai 980-8579
2 shared publicationsAkinobu Matsuyama
1 shared publication- Akinobu Matsuyama
Kyoto University
1 shared publication - Atsushi Fukuyama
Kyoto University
1 shared publication
Latest Publications
- Open Access
- 1 November 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (11)
On use of retarding field analyzers in plasma flow field
The impact of plasma flow on ion temperature (Ti) measurement using retarding field analyzers (RFAs) was experimentally investigated. Experimental results indicated that relatively higher temperature was obtained when the RFA collector was oriented toward the upstream side of the plasma flow, while relatively low Ti was observed on the downstream side. This trend remained consistent regardless of the plasma flow direction to the magnetic field. A simple analytical model that assumes a drifted-Maxwellian distribution explained the results well, suggesting that RFAs overestimate or underestimate Ti due to the plasma flow. While this effect is generally undesirable, it also enables simultaneous evaluation of Ti and plasma flow velocity. In this work, we propose a practical method to determine ion temperature and plasma flow velocity from I–V characteristics that are deformed by plasma flow.
- 1 November 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (11)
Open AccessOn use of retarding field analyzers in plasma flow field
The impact of plasma flow on ion temperature (Ti) measurement using retarding field analyzers (RFAs) was experimentally investigated. Experimental results indicated that relatively higher temperature was obtained when the RFA collector was oriented toward the upstream side of the plasma flow, while relatively low Ti was observed on the downstream side. This trend remained consistent regardless of the plasma flow direction to the magnetic field. A simple analytical model that assumes a drifted-Maxwellian distribution explained the results well, suggesting that RFAs overestimate or underestimate Ti due to the plasma flow. While this effect is generally undesirable, it also enables simultaneous evaluation of Ti and plasma flow velocity. In this work, we propose a practical method to determine ion temperature and plasma flow velocity from I–V characteristics that are deformed by plasma flow.
- Open Access
- 20 August 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (10) , 106011
Observation of tungsten emission spectra up to W46+ ions in the Large Helical Device and contribution to the study of high-Z impurity transport in fusion plasmas
Spectroscopic studies of emissions released from tungsten ions combined with a pellet injection technique have been conducted in Large Helical Device for contribution to the tungsten transport study in tungsten divertor fusion devices and for expansion of the experimental database of tungsten line emissions. The spectral intensities of W5+, W24+–W28+, W37+, W38+, W41+–W43+, W45+, and W46+ emission lines were measured simultaneously over a wide wavelength range from x-ray to visible. Time evolutions of the various tungsten line spectra indicate that the tungsten confinement time depends on the electron density of the plasma and is long in high density plasmas, on the order of seconds, and short in low density plasmas, on the order of sub-seconds. When the confinement time was long, the tungsten ions remained in the plasma until the end of the discharge, changing their dominant charge with the change in electron temperature. When the confinement time was short, the tungsten ions rapidly decreased in all charge states and disappeared. Space-resolved EUV and visible spectroscopy measurements have revealed that tungsten ions stayed in the core region of the plasma with changing their dominant charge state depending on the electron temperature in the discharges with the long confinement time. Detailed analysis of soft x-ray emission suggested that the confinement time increases with density and becomes saturated when the central electron density exceeds 2 × 1013 cm−3.
- 20 August 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (10) , 106011
Open AccessObservation of tungsten emission spectra up to W46+ ions in the Large Helical Device and contribution to the study of high-Z impurity transport in fusion plasmas
Spectroscopic studies of emissions released from tungsten ions combined with a pellet injection technique have been conducted in Large Helical Device for contribution to the tungsten transport study in tungsten divertor fusion devices and for expansion of the experimental database of tungsten line emissions. The spectral intensities of W5+, W24+–W28+, W37+, W38+, W41+–W43+, W45+, and W46+ emission lines were measured simultaneously over a wide wavelength range from x-ray to visible. Time evolutions of the various tungsten line spectra indicate that the tungsten confinement time depends on the electron density of the plasma and is long in high density plasmas, on the order of seconds, and short in low density plasmas, on the order of sub-seconds. When the confinement time was long, the tungsten ions remained in the plasma until the end of the discharge, changing their dominant charge with the change in electron temperature. When the confinement time was short, the tungsten ions rapidly decreased in all charge states and disappeared. Space-resolved EUV and visible spectroscopy measurements have revealed that tungsten ions stayed in the core region of the plasma with changing their dominant charge state depending on the electron temperature in the discharges with the long confinement time. Detailed analysis of soft x-ray emission suggested that the confinement time increases with density and becomes saturated when the central electron density exceeds 2 × 1013 cm−3.
- Open Access
- 28 April 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 203
Systematic numerical analysis of ECCD exploring injection conditions with high CD efficiency and current profile controllability in JA DEMO
- 28 April 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 203
Open AccessSystematic numerical analysis of ECCD exploring injection conditions with high CD efficiency and current profile controllability in JA DEMO
- Open Access
- 1 March 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (3) , 032508
On electron temperature rise in divertor relevant recombining plasma along magnetic field line
The rise of electron temperature along the magnetic field line was clearly observed in divertor relevant recombining plasma, even though there was no additional electron heating source. Electron temperature obtained at recombination front was approximately 0.5 eV, whereas it increased up to greater than 1 eV at downstream of recombination front. Although this temperature rise is likely common in detached or recombining plasmas, the mechanism has not been understood yet. This report provides a reasonable interpretation of temperature rise along the magnetic field line, for the first time: depletion of low energy electrons due to volumetric recombination leads to deformation of electron energy distribution, resulting in an apparent increase in electron temperature. Our experiment supports this interpretation in that the experimentally observed electron temperature showed good agreement with calculated effective electron temperature.
- 1 March 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (3) , 032508
Open AccessOn electron temperature rise in divertor relevant recombining plasma along magnetic field line
The rise of electron temperature along the magnetic field line was clearly observed in divertor relevant recombining plasma, even though there was no additional electron heating source. Electron temperature obtained at recombination front was approximately 0.5 eV, whereas it increased up to greater than 1 eV at downstream of recombination front. Although this temperature rise is likely common in detached or recombining plasmas, the mechanism has not been understood yet. This report provides a reasonable interpretation of temperature rise along the magnetic field line, for the first time: depletion of low energy electrons due to volumetric recombination leads to deformation of electron energy distribution, resulting in an apparent increase in electron temperature. Our experiment supports this interpretation in that the experimentally observed electron temperature showed good agreement with calculated effective electron temperature.
- Open Access
- 1 January 2009
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 4, 008
Numerical Study of the Ripple Resonance Diffusion of Alpha Particles in Tokamaks
- 1 January 2009
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 4, 008
Open AccessNumerical Study of the Ripple Resonance Diffusion of Alpha Particles in Tokamaks
- 16 January 2006
- Published by IOP Publishing in Nuclear Fusion
- Vol. 46 (2) , 285-290
Key achievements in elementary R&D on water-cooled solid breeder blanket for ITER test blanket module in JAERI
- 16 January 2006
- Published by IOP Publishing in Nuclear Fusion
- Vol. 46 (2) , 285-290
Key achievements in elementary R&D on water-cooled solid breeder blanket for ITER test blanket module in JAERI
- 1 January 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 594-596
Infrared TV measurement of fast ion loss on JT-60U
- 1 January 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 594-596
Infrared TV measurement of fast ion loss on JT-60U