Junhyun Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junhyun Park has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Minho Hwang
Department of Robotics and Mechatronics Engineering Daegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu South Korea
2 shared publications - Seonghyeok Jang
Department of Robotics and Mechatronics Engineering Daegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu South Korea
2 shared publications Hyojae Park
Department of Robotics and Mechatronics Engineering Daegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu South Korea
1 shared publication- Hyojae Park
Department of Robotics and Mechatronics Engineering, DGIST, Daegu, South Korea
1 shared publication Jeonghyeon Yoon
Department of Robotics and Mechatronics Engineering Daegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu South Korea
1 shared publicationMyeongbo Park
Department of Robotics and Mechatronics Engineering Daegu Gyeongbuk Institute of Science and Technology (DGIST) Daegu South Korea
1 shared publication
Latest Publications
- 12 December 2024
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (6) , e70014
SAM: Semi‐Active Mechanism for Extensible Continuum Manipulator and Real‐Time Hysteresis Compensation Control Algorithm
Background: Cable‐driven continuum manipulators (CDCMs) enable scar‐free procedures but face limitations in workspace and control accuracy due to hysteresis.Methods: We introduce an extensible CDCM with a semi‐active mechanism (SAM) and develop a real‐time hysteresis compensation control algorithm using a temporal convolution network (TCN) based on data collected from fiducial markers and RGBD sensing.Results: Performance validation shows the proposed controller significantly reduces hysteresis by up to 69.5% in random trajectory tracking test and approximately 26% in the box pointing task.Conclusion: The SAM mechanism enables access to various lesions without damaging surrounding tissues. The proposed controller with TCN‐based compensation effectively predicts hysteresis behaviour and minimises position and joint angle errors in real‐time, which has the potential to enhance surgical task performance.
- 12 December 2024
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (6) , e70014
SAM: Semi‐Active Mechanism for Extensible Continuum Manipulator and Real‐Time Hysteresis Compensation Control Algorithm
Background: Cable‐driven continuum manipulators (CDCMs) enable scar‐free procedures but face limitations in workspace and control accuracy due to hysteresis.Methods: We introduce an extensible CDCM with a semi‐active mechanism (SAM) and develop a real‐time hysteresis compensation control algorithm using a temporal convolution network (TCN) based on data collected from fiducial markers and RGBD sensing.Results: Performance validation shows the proposed controller significantly reduces hysteresis by up to 69.5% in random trajectory tracking test and approximately 26% in the box pointing task.Conclusion: The SAM mechanism enables access to various lesions without damaging surrounding tissues. The proposed controller with TCN‐based compensation effectively predicts hysteresis behaviour and minimises position and joint angle errors in real‐time, which has the potential to enhance surgical task performance.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (7) , 6091-6098
Hysteresis Compensation of Flexible Continuum Manipulator Using RGBD Sensing and Temporal Convolutional Network
Flexible continuum manipulators are valued for minimally invasive surgery, offering access to confined spaces through nonlinear paths. However, cable-driven manipulators face control difficulties due to hysteresis from cabling effects such as friction, elongation, and coupling. These effects are difficult to model due to nonlinearity and the difficulties become even more evident when dealing with long and coupled, multi-segmented manipulator. This letter proposes a data-driven approach based on Deep Neural Networks (DNN) to capture these nonlinear and previous states-dependent characteristics of cable actuation. We collect physical joint configurations according to command joint configurations using RGBD sensing and 7 fiducial markers to model the hysteresis of the proposed manipulator. Result on a study comparing the estimation performance of four DNN models show that the Temporal Convolution Network (TCN) demonstrates the highest predictive capability. Leveraging trained TCNs, we build a control algorithm to compensate for hysteresis. Tracking tests in task space using unseen trajectories show that the proposed control algorithm reduces the average position and orientation error by 61.39% (from $\mathbf {\text{13.7}\,mm}$ to $\mathbf {\text{5.29}\,mm}$ ) and 64.04% (from 31.17 $^{\circ }$ to 11.21 $^{\circ }$ ), respectively. This result implies that the proposed calibrated controller effectively reaches the desired configurations by estimating the hysteresis of the manipulator. Applying this method in real surgical scenarios has the potential to enhance control precision and improve surgical performance.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (7) , 6091-6098
Hysteresis Compensation of Flexible Continuum Manipulator Using RGBD Sensing and Temporal Convolutional Network
Flexible continuum manipulators are valued for minimally invasive surgery, offering access to confined spaces through nonlinear paths. However, cable-driven manipulators face control difficulties due to hysteresis from cabling effects such as friction, elongation, and coupling. These effects are difficult to model due to nonlinearity and the difficulties become even more evident when dealing with long and coupled, multi-segmented manipulator. This letter proposes a data-driven approach based on Deep Neural Networks (DNN) to capture these nonlinear and previous states-dependent characteristics of cable actuation. We collect physical joint configurations according to command joint configurations using RGBD sensing and 7 fiducial markers to model the hysteresis of the proposed manipulator. Result on a study comparing the estimation performance of four DNN models show that the Temporal Convolution Network (TCN) demonstrates the highest predictive capability. Leveraging trained TCNs, we build a control algorithm to compensate for hysteresis. Tracking tests in task space using unseen trajectories show that the proposed control algorithm reduces the average position and orientation error by 61.39% (from $\mathbf {\text{13.7}\,mm}$ to $\mathbf {\text{5.29}\,mm}$ ) and 64.04% (from 31.17 $^{\circ }$ to 11.21 $^{\circ }$ ), respectively. This result implies that the proposed calibrated controller effectively reaches the desired configurations by estimating the hysteresis of the manipulator. Applying this method in real surgical scenarios has the potential to enhance control precision and improve surgical performance.