Hao Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hao Ma has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Wei Yan
Nanjing Normal University
2 shared publications - Hongtian Chen
Shanghai Jiao Tong University
1 shared publication Mengxia Zhou
Nanjing Normal University
1 shared publication- Wu Zhang
School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing, China
1 shared publication - Xuan Liu
Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117575, Singapore
1 shared publication - Yang Zhao
Nanjing Normal Univ, Sch Elect & Automat Engn, Nanjing 210046, Peoples R China
1 shared publication
Latest Publications
- Open Access
- 1 May 2024
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E107.C (5) , 124-131
Effects of Electromagnet Interference on Speed and Position Estimations of Sensorless SPMSM
Model-based sensorless control of permanent magnet synchronous motor (PMSM) is promising for high-speed operation to estimate motor state, which is the speed and the position of the rotor, via electric signals of the stator, beside the inevitable fact that estimation accuracy is degraded by electromagnet interference (EMI) from switching devices of the converter. In this paper, the simulation system based on Luenberger observer and phase-locked loop (PLL) has been established, analyzing impacts of EMI on motor state estimations theoretically, exploring influences of EMI with different cutoff frequency, rated speeds, frequencies and amplitudes. The results show that Luenberger observer and PLL have strong immunity, which enable PMSM can still operate stably even under certain degrees of interference. EMI produces sideband harmonics that enlarge pulsation errors of speed and position estimations. Additionally, estimation errors are positively correlated with cutoff frequency of low-pass filter and the amplitude of EMI, and negatively correlated with rated speed of the motor and the frequency of EMI. When the frequency is too high, its effects on motor state estimations are negligible. This work contributes to the comprehensive understanding of how EMI affects motor state estimations, which further enhances practical application of sensorless PMSM.
- 1 May 2024
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E107.C (5) , 124-131
Open AccessEffects of Electromagnet Interference on Speed and Position Estimations of Sensorless SPMSM
Model-based sensorless control of permanent magnet synchronous motor (PMSM) is promising for high-speed operation to estimate motor state, which is the speed and the position of the rotor, via electric signals of the stator, beside the inevitable fact that estimation accuracy is degraded by electromagnet interference (EMI) from switching devices of the converter. In this paper, the simulation system based on Luenberger observer and phase-locked loop (PLL) has been established, analyzing impacts of EMI on motor state estimations theoretically, exploring influences of EMI with different cutoff frequency, rated speeds, frequencies and amplitudes. The results show that Luenberger observer and PLL have strong immunity, which enable PMSM can still operate stably even under certain degrees of interference. EMI produces sideband harmonics that enlarge pulsation errors of speed and position estimations. Additionally, estimation errors are positively correlated with cutoff frequency of low-pass filter and the amplitude of EMI, and negatively correlated with rated speed of the motor and the frequency of EMI. When the frequency is too high, its effects on motor state estimations are negligible. This work contributes to the comprehensive understanding of how EMI affects motor state estimations, which further enhances practical application of sensorless PMSM.
- 8 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 712-723
Research on Interferences of VFTO to Irregular Distributions of Secondary Side Cables
In the digital era, the secondary equipment of power system is becoming more and more sensitive to electromagnetic interference. Gas insulated switchgear (GIS) in substations will generate very fast transient overvoltage (VFTO) after switching action. The VFTO will generate transient electromagnetic fields and cause interferences to the secondary side cables. In recent years, the anti-interference measures for cable protection have been greatly improved. However, in the current cable trenches of some substations, there are still many irregular cable arrangements. It may have some influences on the electromagnetic interference to the cable generated by VFTO. This paper expresses a method for finding the exact interference areas of the cable and standardizing the wiring standard of the cable. Firstly, the relationship between the cable position variation and parameters is analyzed. Then, simulation experiments based on speculation are conducted to observe the effect of irregular cable arrangement on port voltage, and computer software simulation is performed for comparison. After that, an irregular cable is simulated and an interval type Ⅱ fuzzy neural network is used to predict the parameters of the shielding layer of the cable at each irregularly arranged point. Finally, the voltage and current at each point of the cable shield are calculated through the finite-difference time-domain (FDTD) algorithm. In this manner, the actual position of the higher interference voltage can be determined, which can provide a reference standard for cable arrangement.
- 8 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 712-723
Research on Interferences of VFTO to Irregular Distributions of Secondary Side Cables
In the digital era, the secondary equipment of power system is becoming more and more sensitive to electromagnetic interference. Gas insulated switchgear (GIS) in substations will generate very fast transient overvoltage (VFTO) after switching action. The VFTO will generate transient electromagnetic fields and cause interferences to the secondary side cables. In recent years, the anti-interference measures for cable protection have been greatly improved. However, in the current cable trenches of some substations, there are still many irregular cable arrangements. It may have some influences on the electromagnetic interference to the cable generated by VFTO. This paper expresses a method for finding the exact interference areas of the cable and standardizing the wiring standard of the cable. Firstly, the relationship between the cable position variation and parameters is analyzed. Then, simulation experiments based on speculation are conducted to observe the effect of irregular cable arrangement on port voltage, and computer software simulation is performed for comparison. After that, an irregular cable is simulated and an interval type Ⅱ fuzzy neural network is used to predict the parameters of the shielding layer of the cable at each irregularly arranged point. Finally, the voltage and current at each point of the cable shield are calculated through the finite-difference time-domain (FDTD) algorithm. In this manner, the actual position of the higher interference voltage can be determined, which can provide a reference standard for cable arrangement.