G Savarese
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
G Savarese has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Domenico Pecora
Poliambulanza Foundation Hospital Institute of Brescia , Brescia , Italy
2 shared publications - Miguel Viscusi
Hospital Sant'anna E San Sebastiano , Caserta , Italy
2 shared publications - Sergio Valsecchi
Boston Scientific Italia Milan Italy
2 shared publications V E Santobuono
Università degli studi di Bari “Aldo Moro” – Policlinico di Bari , Bari , Italy
2 shared publicationsA D'ONofrio
AORN Ospedali dei Colli - Monaldi Hospital , Naples , Italy
1 shared publicationA Salucci
University of Naples Federico II , Naples , Italy
1 shared publication
Latest Publications
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Adherence to remote monitoring recommendations in current clinical practice: data from a remote monitoring database
Background: The recently published Expert Consensus Statement on the Practical Management of Remote Device Clinic offers evidence-based recommendations for managing patients with cardiovascular implantable electronic devices (CIEDs). Purpose: We examined data from a remote monitoring (RM) database to evaluate adherence to RM recommendations in current clinical practice. Methods: According to RM guidelines, patients should be enrolled within 2 weeks of implantation for earlier detection of actionable events, and in any case, within 3 months, as it is associated with improved survival. Continuous connectivity should be maintained. In patients with continuous connectivity, alert-based RM may replace structured intermittent device follow-up. We analyzed data from 4427 CIED patients followed on the LATITUDE (Boston Scientific) remote network at 20 Italian centers. Patients were enrolled between 2010 and 2023, with a median RM duration of 37 months (25th-75th percentile: 21-60). Results: The number of patients enrolled at the centers significantly increased during the observation period (Figure). In the overall RM population, we identified a group of patients (56%) enrolled after implantation (within 6 months) and a group of patients enrolled late during their follow-up. In the first group, RM receiver activation occurred within 2 weeks in 62% and within 3 months in 90% of patients. The second group consisted mainly of patients not yet in RM at the time of COVID-19 outbreak and included to allow RM of all patients at the centers. Overall, 96% of enrolled patients performed remote data transmissions during the observation period. As of the July 2023 data extraction, 1405 (33%) patients were not monitored, with no significant differences among CIED types (CRT-D: 37%; ICD: 32%; S-ICD: 32; Pacemaker: 30%). Most not-monitored patients (30%) had not transmitted data for over a year, likely due to patient death, CIED extraction, or other irreversible causes. For the remaining 3%, the recent loss of connection (occurring within a timeframe shorter than the scheduled transmission interval) should have prompted interventions to restore connection. Scheduled device transmissions occurred at least once every 3 months in 94% of patients. Considering individual device programming, the 2836 patients with consistent connectivity performed 25,281 scheduled transmissions in one year. Conclusions: In current clinical practice, RM adoption is continually increasing, with generally observed adherence to post-implantation patient enrollment recommendations. However, a significant proportion of patients may activate RM earlier. Centers must implement solutions to ensure transmission continuity in a substantial percentage of patients. Nevertheless, the workload generated by this activity could be effectively balanced by adopting an alert-based RM strategy and reducing unnecessary scheduled transmissions.Enrolled patients trend
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessAdherence to remote monitoring recommendations in current clinical practice: data from a remote monitoring database
Background: The recently published Expert Consensus Statement on the Practical Management of Remote Device Clinic offers evidence-based recommendations for managing patients with cardiovascular implantable electronic devices (CIEDs). Purpose: We examined data from a remote monitoring (RM) database to evaluate adherence to RM recommendations in current clinical practice. Methods: According to RM guidelines, patients should be enrolled within 2 weeks of implantation for earlier detection of actionable events, and in any case, within 3 months, as it is associated with improved survival. Continuous connectivity should be maintained. In patients with continuous connectivity, alert-based RM may replace structured intermittent device follow-up. We analyzed data from 4427 CIED patients followed on the LATITUDE (Boston Scientific) remote network at 20 Italian centers. Patients were enrolled between 2010 and 2023, with a median RM duration of 37 months (25th-75th percentile: 21-60). Results: The number of patients enrolled at the centers significantly increased during the observation period (Figure). In the overall RM population, we identified a group of patients (56%) enrolled after implantation (within 6 months) and a group of patients enrolled late during their follow-up. In the first group, RM receiver activation occurred within 2 weeks in 62% and within 3 months in 90% of patients. The second group consisted mainly of patients not yet in RM at the time of COVID-19 outbreak and included to allow RM of all patients at the centers. Overall, 96% of enrolled patients performed remote data transmissions during the observation period. As of the July 2023 data extraction, 1405 (33%) patients were not monitored, with no significant differences among CIED types (CRT-D: 37%; ICD: 32%; S-ICD: 32; Pacemaker: 30%). Most not-monitored patients (30%) had not transmitted data for over a year, likely due to patient death, CIED extraction, or other irreversible causes. For the remaining 3%, the recent loss of connection (occurring within a timeframe shorter than the scheduled transmission interval) should have prompted interventions to restore connection. Scheduled device transmissions occurred at least once every 3 months in 94% of patients. Considering individual device programming, the 2836 patients with consistent connectivity performed 25,281 scheduled transmissions in one year. Conclusions: In current clinical practice, RM adoption is continually increasing, with generally observed adherence to post-implantation patient enrollment recommendations. However, a significant proportion of patients may activate RM earlier. Centers must implement solutions to ensure transmission continuity in a substantial percentage of patients. Nevertheless, the workload generated by this activity could be effectively balanced by adopting an alert-based RM strategy and reducing unnecessary scheduled transmissions.Enrolled patients trend
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Association between amount of biventricular pacing and heart failure status measured by a multisensor implantable defibrillator algorithm
Background: Achieving a high biventricular pacing percentage (BiV%) is crucial for optimizing outcomes in cardiac resynchronization therapy (CRT). The HeartLogic index, a multiparametric heart failure (HF) risk score, incorporates implantable defibrillator (ICD)-measured variables and has demonstrated its predictive ability for impending HF decompensation. Purpose: This study aimed to investigate the relationship between daily BiV% in CRT ICD patients and their HF status, assessed using the HeartLogic algorithm. Methods: The HeartLogic algorithm was activated in 306 patients across 26 centers, with a median follow-up of 26 months (25th–75th percentile: 15-37). Results: During the follow-up period, 619 HeartLogic alerts were recorded in 186 patients. Overall, daily values associated with the best clinical status (highest first heart sound, intrathoracic impedance, patient activity; lowest combined index, third heart sound, respiration rate, night heart rate) were associated with a BiV% exceeding 99%. We identified 455 instances of BiV% dropping below 98% after consistent pacing periods. Longer episodes of reduced BiV% (hazard ratio: 2.68; 95% CI: 1.02-9.72; P=0.045) and lower BiV% (hazard ratio: 3.97; 95% CI: 1.74-9.06; P=0.001) were linked to a higher risk of HeartLogic alerts. BiV% drops exceeding 7 days predicted alerts with 90% sensitivity (95% CI [74%-98%]) and 55% specificity (95% CI [51%-60%]), while BiV% ≤96% predicted alerts with 74% sensitivity (95% CI [55%-88%]) and 81% specificity (95% CI [77%-85%]). Conclusions: A clear correlation was observed between reduced daily BiV% and worsening clinical conditions, as indicated by the HeartLogic index. Importantly, even minor reductions in pacing percentage and duration were associated with an increased risk of HF alerts.Time to event
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessAssociation between amount of biventricular pacing and heart failure status measured by a multisensor implantable defibrillator algorithm
Background: Achieving a high biventricular pacing percentage (BiV%) is crucial for optimizing outcomes in cardiac resynchronization therapy (CRT). The HeartLogic index, a multiparametric heart failure (HF) risk score, incorporates implantable defibrillator (ICD)-measured variables and has demonstrated its predictive ability for impending HF decompensation. Purpose: This study aimed to investigate the relationship between daily BiV% in CRT ICD patients and their HF status, assessed using the HeartLogic algorithm. Methods: The HeartLogic algorithm was activated in 306 patients across 26 centers, with a median follow-up of 26 months (25th–75th percentile: 15-37). Results: During the follow-up period, 619 HeartLogic alerts were recorded in 186 patients. Overall, daily values associated with the best clinical status (highest first heart sound, intrathoracic impedance, patient activity; lowest combined index, third heart sound, respiration rate, night heart rate) were associated with a BiV% exceeding 99%. We identified 455 instances of BiV% dropping below 98% after consistent pacing periods. Longer episodes of reduced BiV% (hazard ratio: 2.68; 95% CI: 1.02-9.72; P=0.045) and lower BiV% (hazard ratio: 3.97; 95% CI: 1.74-9.06; P=0.001) were linked to a higher risk of HeartLogic alerts. BiV% drops exceeding 7 days predicted alerts with 90% sensitivity (95% CI [74%-98%]) and 55% specificity (95% CI [51%-60%]), while BiV% ≤96% predicted alerts with 74% sensitivity (95% CI [55%-88%]) and 81% specificity (95% CI [77%-85%]). Conclusions: A clear correlation was observed between reduced daily BiV% and worsening clinical conditions, as indicated by the HeartLogic index. Importantly, even minor reductions in pacing percentage and duration were associated with an increased risk of HF alerts.Time to event