Yichu Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yichu Jin has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Conor James Walsh
Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
7 shared publications - Jonathan T. Alvarez
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
3 shared publications - Connor M. McCann
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, USA
2 shared publications Elizabeth L. Suitor
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, USA
2 shared publications- Krithika Swaminathan
Department of Bioengineering, Stanford University, Stanford, California, USA
2 shared publications Prabhat Pathak
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, USA
2 shared publications
Latest Publications
- Top Cited Papers
- 6 April 2026
- Published by Springer Nature in Nature Sensors
- Vol. 1 (6) , 502-512
Minimal-calibration multimodal wearable sensing for long-duration three-dimensional shoulder kinematics
- 6 April 2026
- Published by Springer Nature in Nature Sensors
- Vol. 1 (6) , 502-512
Top Cited PapersMinimal-calibration multimodal wearable sensing for long-duration three-dimensional shoulder kinematics
- Open Access
- 2 August 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-14
Personalized ML-based wearable robot control improves impaired arm function
Portable wearable robots offer promise for assisting people with upper limb disabilities. However, movement variability between individuals and trade-offs between supportiveness and transparency complicate robot control during real-world tasks. We address these challenges by first developing a personalized ML intention detection model to decode user’s motion intention from IMU and compression sensors. Second, we leverage a physics-based hysteresis model to enhance control transparency and adapt it for practical use in real-world tasks. Third, we combine and integrate these two models into a real-time controller to modulate the assistance level based on the user’s intention and kinematic state. Fourth, we evaluate the effectiveness of our control strategy in improving arm function in a multi-day evaluation. For 5 individuals post-stroke and 4 living with ALS wearing a soft shoulder robot, we demonstrate that the controller identifies shoulder movement with 94.2% accuracy from minimal change in the shoulder angles (elevation: 3.4°, depression: 1.7°) and reduces arm-lowering force by 31.9% compared to a baseline controller. Furthermore, the robot improves movement quality by increasing their shoulder elevation/depression (17.5°), elbow (10.6°) and wrist flexion/extension (7.6°) ROMs; reducing trunk compensation (up to 25.4%); and improving hand-path efficiency (up to 53.8%).
- 2 August 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-14
Open AccessPersonalized ML-based wearable robot control improves impaired arm function
Portable wearable robots offer promise for assisting people with upper limb disabilities. However, movement variability between individuals and trade-offs between supportiveness and transparency complicate robot control during real-world tasks. We address these challenges by first developing a personalized ML intention detection model to decode user’s motion intention from IMU and compression sensors. Second, we leverage a physics-based hysteresis model to enhance control transparency and adapt it for practical use in real-world tasks. Third, we combine and integrate these two models into a real-time controller to modulate the assistance level based on the user’s intention and kinematic state. Fourth, we evaluate the effectiveness of our control strategy in improving arm function in a multi-day evaluation. For 5 individuals post-stroke and 4 living with ALS wearing a soft shoulder robot, we demonstrate that the controller identifies shoulder movement with 94.2% accuracy from minimal change in the shoulder angles (elevation: 3.4°, depression: 1.7°) and reduces arm-lowering force by 31.9% compared to a baseline controller. Furthermore, the robot improves movement quality by increasing their shoulder elevation/depression (17.5°), elbow (10.6°) and wrist flexion/extension (7.6°) ROMs; reducing trunk compensation (up to 25.4%); and improving hand-path efficiency (up to 53.8%).
- Open Access
- 11 April 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-11
Learning-based 3D human kinematics estimation using behavioral constraints from activity classification
Inertial measurement units offer a cost-effective, portable alternative to lab-based motion capture systems. However, measuring joint angles and movement trajectories with inertial measurement units is challenging due to signal drift errors caused by biases and noise, which are amplified by numerical integration. Existing approaches use anatomical constraints to reduce drift but require body parameter measurements. Learning-based approaches show promise but often lack accuracy for broad applications (e.g., strength training). Here, we introduce the Activity-in-the-loop Kinematics Estimator, an end-to-end machine learning model incorporating human behavioral constraints for enhanced kinematics estimation using two inertial measurement units. It integrates activity classification with kinematics estimation, leveraging limited movement patterns during specific activities. In dynamic scenarios, our approach achieved trajectory and shoulder joint angle errors under 0.021 m and \(6.5^\circ\), respectively, 52% and 17% lower than errors without including activity classification. These results highlight accurate motion tracking with minimal inertial measurement units and domain-specific context.- 11 April 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-11
Open AccessLearning-based 3D human kinematics estimation using behavioral constraints from activity classification
Inertial measurement units offer a cost-effective, portable alternative to lab-based motion capture systems. However, measuring joint angles and movement trajectories with inertial measurement units is challenging due to signal drift errors caused by biases and noise, which are amplified by numerical integration. Existing approaches use anatomical constraints to reduce drift but require body parameter measurements. Learning-based approaches show promise but often lack accuracy for broad applications (e.g., strength training). Here, we introduce the Activity-in-the-loop Kinematics Estimator, an end-to-end machine learning model incorporating human behavioral constraints for enhanced kinematics estimation using two inertial measurement units. It integrates activity classification with kinematics estimation, leveraging limited movement patterns during specific activities. In dynamic scenarios, our approach achieved trajectory and shoulder joint angle errors under 0.021 m and \(6.5^\circ\), respectively, 52% and 17% lower than errors without including activity classification. These results highlight accurate motion tracking with minimal inertial measurement units and domain-specific context. - Open Access
- 4 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 10-21
Stimulation-Induced Muscle Deformation Measured With A-Mode Ultrasound Correlates With Muscle Fatigue
Muscle fatigue is a common physiological phenomenon whose onset can impair physical performance and increase the risk of injury. Traditional assessments of muscle fatigue are primarily constrained by their dependence on maximum voluntary contractions (MVCs), which not only rely heavily on participant motivation, reducing measurement accuracy, but also require large, stationary equipment such as isokinetic dynamometers, limiting their application to discrete assessments in lab-based environments. In this work, we introduce a wearable muscle fatigue tracking strategy that employs low-profile single-element ultrasound and electrical stimulation. This integrated approach demonstrates that muscle deformation from electrically-induced muscle contractions correlates with muscle fatigue, thus circumventing the need for bulky hardware and eliminating the variability associated with human volition. We define a deformation index, which fuses stimulation-induced changes in muscle thickness with baseline muscle swelling to track muscle fatigue. Our results demonstrate that the deformation index reliably tracks muscle fatigue ( r = 0.85 ± 0.15), under specific conditions, namely extended joint angles and increased stimulation, as measured by changes in knee extension torque during a series of dynamic, volitional fatiguing contractions on 8 subjects on an isokinetic dynamometer. This approach has the potential to enable real-time, semi-continuous muscle fatigue monitoring in unconstrained environments.
- 4 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 10-21
Open AccessStimulation-Induced Muscle Deformation Measured With A-Mode Ultrasound Correlates With Muscle Fatigue
Muscle fatigue is a common physiological phenomenon whose onset can impair physical performance and increase the risk of injury. Traditional assessments of muscle fatigue are primarily constrained by their dependence on maximum voluntary contractions (MVCs), which not only rely heavily on participant motivation, reducing measurement accuracy, but also require large, stationary equipment such as isokinetic dynamometers, limiting their application to discrete assessments in lab-based environments. In this work, we introduce a wearable muscle fatigue tracking strategy that employs low-profile single-element ultrasound and electrical stimulation. This integrated approach demonstrates that muscle deformation from electrically-induced muscle contractions correlates with muscle fatigue, thus circumventing the need for bulky hardware and eliminating the variability associated with human volition. We define a deformation index, which fuses stimulation-induced changes in muscle thickness with baseline muscle swelling to track muscle fatigue. Our results demonstrate that the deformation index reliably tracks muscle fatigue ( r = 0.85 ± 0.15), under specific conditions, namely extended joint angles and increased stimulation, as measured by changes in knee extension torque during a series of dynamic, volitional fatiguing contractions on 8 subjects on an isokinetic dynamometer. This approach has the potential to enable real-time, semi-continuous muscle fatigue monitoring in unconstrained environments.
- Top Cited PapersOpen Access
- 9 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-12
Estimation of joint torque in dynamic activities using wearable A-mode ultrasound
The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement. Here, we present a strategy for estimating corresponding joint torque from muscles with different architectures during various dynamic activities using wearable A-mode ultrasound. We first introduce a method to track changes in muscle thickness using single-element ultrasonic transducers. We then estimate elbow and knee torque with errors less than 7.6% and coefficients of determination (R2) greater than 0.92 during controlled isokinetic contractions. Finally, we demonstrate wearable joint torque estimation during dynamic real-world tasks, including weightlifting, cycling, and both treadmill and outdoor locomotion. The capability to assess joint torque during unconstrained real-world activities can provide new insights into muscle function and movement biomechanics, with potential applications in injury prevention and rehabilitation.
- 9 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-12
Top Cited PapersOpen AccessEstimation of joint torque in dynamic activities using wearable A-mode ultrasound
The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement. Here, we present a strategy for estimating corresponding joint torque from muscles with different architectures during various dynamic activities using wearable A-mode ultrasound. We first introduce a method to track changes in muscle thickness using single-element ultrasonic transducers. We then estimate elbow and knee torque with errors less than 7.6% and coefficients of determination (R2) greater than 0.92 during controlled isokinetic contractions. Finally, we demonstrate wearable joint torque estimation during dynamic real-world tasks, including weightlifting, cycling, and both treadmill and outdoor locomotion. The capability to assess joint torque during unconstrained real-world activities can provide new insights into muscle function and movement biomechanics, with potential applications in injury prevention and rehabilitation.
- Top Cited Papers
- 12 June 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 9 (91) , eadi2377
A portable inflatable soft wearable robot to assist the shoulder during industrial work
Repetitive overhead tasks during factory work can cause shoulder injuries resulting in impaired health and productivity loss. Soft wearable upper extremity robots have the potential to be effective injury prevention tools with minimal restrictions using soft materials and active controls. We present the design and evaluation of a portable inflatable shoulder wearable robot for assisting industrial workers during shoulder-elevated tasks. The robot is worn like a shirt with integrated textile pneumatic actuators, inertial measurement units, and a portable actuation unit. It can provide up to 6.6 newton-meters of torque to support the shoulder and cycle assistance on and off at six times per minute. From human participant evaluations during simulated industrial tasks, the robot reduced agonist muscle activities (anterior, middle, and posterior deltoids and biceps brachii) by up to 40% with slight changes in joint angles of less than 7% range of motion while not increasing antagonistic muscle activity (latissimus dorsi) in current sample size. Comparison of controller parameters further highlighted that higher assistance magnitude and earlier assistance timing resulted in statistically significant muscle activity reductions. During a task circuit with dynamic transitions among the tasks, the kinematics-based controller of the robot showed robustness to misinflations (96% true negative rate and 91% true positive rate), indicating minimal disturbances to the user when assistance was not required. A preliminary evaluation of a pressure modulation profile also highlighted a trade-off between user perception and hardware demands. Finally, five automotive factory workers used the robot in a pilot manufacturing area and provided feedback.
- 12 June 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 9 (91) , eadi2377
Top Cited PapersA portable inflatable soft wearable robot to assist the shoulder during industrial work
Repetitive overhead tasks during factory work can cause shoulder injuries resulting in impaired health and productivity loss. Soft wearable upper extremity robots have the potential to be effective injury prevention tools with minimal restrictions using soft materials and active controls. We present the design and evaluation of a portable inflatable shoulder wearable robot for assisting industrial workers during shoulder-elevated tasks. The robot is worn like a shirt with integrated textile pneumatic actuators, inertial measurement units, and a portable actuation unit. It can provide up to 6.6 newton-meters of torque to support the shoulder and cycle assistance on and off at six times per minute. From human participant evaluations during simulated industrial tasks, the robot reduced agonist muscle activities (anterior, middle, and posterior deltoids and biceps brachii) by up to 40% with slight changes in joint angles of less than 7% range of motion while not increasing antagonistic muscle activity (latissimus dorsi) in current sample size. Comparison of controller parameters further highlighted that higher assistance magnitude and earlier assistance timing resulted in statistically significant muscle activity reductions. During a task circuit with dynamic transitions among the tasks, the kinematics-based controller of the robot showed robustness to misinflations (96% true negative rate and 91% true positive rate), indicating minimal disturbances to the user when assistance was not required. A preliminary evaluation of a pressure modulation profile also highlighted a trade-off between user perception and hardware demands. Finally, five automotive factory workers used the robot in a pilot manufacturing area and provided feedback.
- 19 May 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 9 (15)
Surface‐Level Muscle Deformation as a Correlate for Joint Torque
Wearable technology excels in estimating kinematic and physiological data, but estimating biological torques remains an open challenge. Deformation of the skin above contracting muscles—surface‐level muscle deformation—has emerged as a promising signal for joint torque estimation. However, a lack of ground‐truth measures of surface‐level muscle deformation has complicated the evaluation of wearable sensors designed to measure surface‐level muscle deformation. A non‐contact methodology is proposed for ground‐truth measurement of surface‐level muscle deformation using a 2D laser profilometer. It shows how three metrics of surface‐level muscle deformation—peak radial displacement: r = 0.94 ± 0.05, surface curvature: r = 0.78 ± 0.10, surface strain: r = 0.83 ± 0.12—correlate strongly to changes in volitional elbow torque, further exploring the impact of measurement location or joint angle on these relationships. A nonlinear, lead‐lag relationship between surface‐level muscle deformation and torque is also found. The findings suggest that surface‐level muscle deformation is a promising signal for non‐invasive, real‐time estimates of torque. By standardizing measurement, the methodology can help inform the design of future wearable sensors.
- 19 May 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 9 (15)
Surface‐Level Muscle Deformation as a Correlate for Joint Torque
Wearable technology excels in estimating kinematic and physiological data, but estimating biological torques remains an open challenge. Deformation of the skin above contracting muscles—surface‐level muscle deformation—has emerged as a promising signal for joint torque estimation. However, a lack of ground‐truth measures of surface‐level muscle deformation has complicated the evaluation of wearable sensors designed to measure surface‐level muscle deformation. A non‐contact methodology is proposed for ground‐truth measurement of surface‐level muscle deformation using a 2D laser profilometer. It shows how three metrics of surface‐level muscle deformation—peak radial displacement: r = 0.94 ± 0.05, surface curvature: r = 0.78 ± 0.10, surface strain: r = 0.83 ± 0.12—correlate strongly to changes in volitional elbow torque, further exploring the impact of measurement location or joint angle on these relationships. A nonlinear, lead‐lag relationship between surface‐level muscle deformation and torque is also found. The findings suggest that surface‐level muscle deformation is a promising signal for non‐invasive, real‐time estimates of torque. By standardizing measurement, the methodology can help inform the design of future wearable sensors.