Maurits C. E. F. Wijffels
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maurits C. E. F. Wijffels has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Alan Bulava
České Budějovice Hospital and Faculty of Health and Social Sciences, University of South Bohemia in České Budějovice , České Budějovice
1 shared publication - Ales Mokracek
Kardiochirurgické oddělení Kardiocentrum
1 shared publication - Bakhtawar Khan Mahmoodi
Department of Cardiology St. Antonius Hospital Nieuwegein The Netherlands
1 shared publication - Bart Pieter Van Putte
Department of Cardiothoracic Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
1 shared publication D Kosior
Central Research Hospital the Ministry of The Interior and Administration , Warsaw , Poland
1 shared publication- Gerold Mönnig
Schuechtermann Klinik , Bad Rothenfelde , Germany
1 shared publication
Latest Publications
- Open Access
- 10 August 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (8) , 379
Mapping Efficiency of an Octaspline Versus Pentaspline Multielectrode Catheter for High-Density Mapping of Regular Atrial Tachyarrhythmias: A Multicenter Randomized Cross-Over Trial
Background: Catheter ablation of regular atrial tachyarrhythmias (ATs) relies on high-density electroanatomical mapping and can be technically challenging. We compared the mapping efficiency of the Octaray and Pentaray catheters in patients undergoing AT mapping. Methods: Patients with either left or right AT underwent three-dimensional Coherent mapping using both the Octaray and Pentaray catheters in a randomized cross-over design. The primary endpoint was the total number of electrograms acquired per map at a predefined filling threshold of 5 mm. Results: A total of 46 patients with left or right AT were enrolled across three ablation centers. Successful mapping with both catheters was achieved in 39 patients (20 left ATs and 19 right ATs). The median number of electrograms acquired per map (7437 vs. 4679; p < 0.001) and median electrogram density (50.2 vs. 29.8 electrograms/cm2; p < 0.001) was significantly higher with Octaray than with Pentaray. Furthermore, median mapping times were significantly shorter with Octaray (5.4 vs. 8.1 min; p < 0.001), resulting in an approximately 2.5-fold higher acquisition rate (1489 vs. 602 electrograms/minute; p < 0.001). In addition, Octaray demonstrated a significantly lower proportion of internal points compared with Pentaray, particularly in low-voltage regions (bipolar voltage < 0.5 mV; 22% vs. 44%; p = 0.01). Conclusions: Compared with Pentaray, use of the Octaray catheter facilitated faster high-density electroanatomical mapping of complex ATs, thereby improving mapping efficiency.
- 10 August 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (8) , 379
Open AccessMapping Efficiency of an Octaspline Versus Pentaspline Multielectrode Catheter for High-Density Mapping of Regular Atrial Tachyarrhythmias: A Multicenter Randomized Cross-Over Trial
Background: Catheter ablation of regular atrial tachyarrhythmias (ATs) relies on high-density electroanatomical mapping and can be technically challenging. We compared the mapping efficiency of the Octaray and Pentaray catheters in patients undergoing AT mapping. Methods: Patients with either left or right AT underwent three-dimensional Coherent mapping using both the Octaray and Pentaray catheters in a randomized cross-over design. The primary endpoint was the total number of electrograms acquired per map at a predefined filling threshold of 5 mm. Results: A total of 46 patients with left or right AT were enrolled across three ablation centers. Successful mapping with both catheters was achieved in 39 patients (20 left ATs and 19 right ATs). The median number of electrograms acquired per map (7437 vs. 4679; p < 0.001) and median electrogram density (50.2 vs. 29.8 electrograms/cm2; p < 0.001) was significantly higher with Octaray than with Pentaray. Furthermore, median mapping times were significantly shorter with Octaray (5.4 vs. 8.1 min; p < 0.001), resulting in an approximately 2.5-fold higher acquisition rate (1489 vs. 602 electrograms/minute; p < 0.001). In addition, Octaray demonstrated a significantly lower proportion of internal points compared with Pentaray, particularly in low-voltage regions (bipolar voltage < 0.5 mV; 22% vs. 44%; p = 0.01). Conclusions: Compared with Pentaray, use of the Octaray catheter facilitated faster high-density electroanatomical mapping of complex ATs, thereby improving mapping efficiency.
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Two-year safety and effectiveness of hybrid ablation versus catheter ablation in patients with non-paroxysmal AF: mid-term results of the CEASE-AF trial
Background: Hybrid Ablation for atrial fibrillation (AF) combines epicardial and endocardial ablation through a Heart Team approach to target durable, transmural isolation of the pulmonary veins (PV) and left atrial posterior wall (LAPW). While the primary efficacy endpoint at 12 months was met with a significant benefit increase for hybrid ablation, we now report the midterm durability of those results. Purpose: To evaluate 24-months safety and effectiveness of Hybrid Ablation with left atrial appendage exclusion (LAAE) versus Catheter Ablation in patients with persistent AF/enlarged left atrium and longstanding persistent AF (LSPAF). Methods: CEASE-AF is a prospective, multi-center, 2:1 randomized controlled trial. Eligible patients were 18-75 years of age, had symptomatic, drug-refractory persistent AF and enlarged left atrium (>4 cm) or LSPAF, and were undergoing a first ablation. Hybrid Ablation consisted of two stages: thoracoscopic epicardial radiofrequency (RF) ablation for PV and LAPW isolation and epicardial LAAE followed by endocardial ablation 91-180 days later. Catheter Ablation consisted of minimum PV isolation by endocardial RF ablation, and repeat ablation was allowed between 91-180 days. In both arms, additional lesions were permitted according to institutional practices. Effectiveness was freedom from AF/atrial flutter (AFL)/atrial tachycardia (AT) off anti-arrhythmic drugs (AAD) (except AADs not exceeding doses which previously failed) and was assessed through 48-h Holter monitoring reviewed by an independent core laboratory blinded to the study. Safety was major adverse events throughout the study, adjudicated by an independent Clinical Events Committee. Results: There were 102 Hybrid Ablation and 52 Catheter Ablation patients; 26% were female, mean age was 60.7±7.9 years, mean LAD was 4.7±0.4 cm, and 19% had LSPAF with no differences between arms. The 12- and 24-month results are shown for comparison (Table). Through 24-months, effectiveness was 66.3% (63/95) in the Hybrid Arm and 33.3% (17/51) in the Catheter Arm (absolute difference 33.0% [95% CI 14.3%, 48.3%; p<0.001]). Major adverse event rates through 24-months were statistically similar at 10.8% (11/102) in the Hybrid Arm and 9.6% (5/52) in the Catheter Arm (p=1.0). Through 24-months, repeat ablations were performed in 7.4% (7/95) of the Hybrid Arm versus 37.3% (19/51) of the Catheter Arm (p<0.001), and cardioversions were performed in 14.7% (14/95) of the Hybrid Arm versus 29.4% (15/51) of the Catheter Arm (p=0.034) Conclusions: CEASE-AF demonstrated that superior effectiveness of Hybrid Ablation including LAAE versus Catheter Ablation was durable through 24-month follow-up, with 33% absolute improvement in freedom from AF/AFL/AT. Safety rates continued to be similar between arms. Three-year follow-up is ongoing.
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessTwo-year safety and effectiveness of hybrid ablation versus catheter ablation in patients with non-paroxysmal AF: mid-term results of the CEASE-AF trial
Background: Hybrid Ablation for atrial fibrillation (AF) combines epicardial and endocardial ablation through a Heart Team approach to target durable, transmural isolation of the pulmonary veins (PV) and left atrial posterior wall (LAPW). While the primary efficacy endpoint at 12 months was met with a significant benefit increase for hybrid ablation, we now report the midterm durability of those results. Purpose: To evaluate 24-months safety and effectiveness of Hybrid Ablation with left atrial appendage exclusion (LAAE) versus Catheter Ablation in patients with persistent AF/enlarged left atrium and longstanding persistent AF (LSPAF). Methods: CEASE-AF is a prospective, multi-center, 2:1 randomized controlled trial. Eligible patients were 18-75 years of age, had symptomatic, drug-refractory persistent AF and enlarged left atrium (>4 cm) or LSPAF, and were undergoing a first ablation. Hybrid Ablation consisted of two stages: thoracoscopic epicardial radiofrequency (RF) ablation for PV and LAPW isolation and epicardial LAAE followed by endocardial ablation 91-180 days later. Catheter Ablation consisted of minimum PV isolation by endocardial RF ablation, and repeat ablation was allowed between 91-180 days. In both arms, additional lesions were permitted according to institutional practices. Effectiveness was freedom from AF/atrial flutter (AFL)/atrial tachycardia (AT) off anti-arrhythmic drugs (AAD) (except AADs not exceeding doses which previously failed) and was assessed through 48-h Holter monitoring reviewed by an independent core laboratory blinded to the study. Safety was major adverse events throughout the study, adjudicated by an independent Clinical Events Committee. Results: There were 102 Hybrid Ablation and 52 Catheter Ablation patients; 26% were female, mean age was 60.7±7.9 years, mean LAD was 4.7±0.4 cm, and 19% had LSPAF with no differences between arms. The 12- and 24-month results are shown for comparison (Table). Through 24-months, effectiveness was 66.3% (63/95) in the Hybrid Arm and 33.3% (17/51) in the Catheter Arm (absolute difference 33.0% [95% CI 14.3%, 48.3%; p<0.001]). Major adverse event rates through 24-months were statistically similar at 10.8% (11/102) in the Hybrid Arm and 9.6% (5/52) in the Catheter Arm (p=1.0). Through 24-months, repeat ablations were performed in 7.4% (7/95) of the Hybrid Arm versus 37.3% (19/51) of the Catheter Arm (p<0.001), and cardioversions were performed in 14.7% (14/95) of the Hybrid Arm versus 29.4% (15/51) of the Catheter Arm (p=0.034) Conclusions: CEASE-AF demonstrated that superior effectiveness of Hybrid Ablation including LAAE versus Catheter Ablation was durable through 24-month follow-up, with 33% absolute improvement in freedom from AF/AFL/AT. Safety rates continued to be similar between arms. Three-year follow-up is ongoing.