Behnam Moradkhani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Behnam Moradkhani has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Yash Chitalia
Speed School of Engineering, University of Louisville, Louisville, KY, USA
4 shared publications - Pejman Kheradmand
Healthcare Robotics and Telesurgery (HeaRT) Laboratory, J. B. Speed School of Engineering, University of Louisville, Louisville, Kentucky, USA
3 shared publications - Harshith Jella
Healthcare Robotics and Telesurgery (HeaRT) Laboratory, Speed School of Engineering, University of Louisville, Louisville, KY, USA
2 shared publications Patrick J. Codd
Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA
2 shared publications- Tanner J. Zachem
Duke University School of Medicine Durham North Carolina USA
2 shared publications Ajmal Zemmar
1 shared publication
Latest Publications
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. PP (3) , 1
A Comprehensive General Model of Tendon-Actuated Concentric Tube Robots with Multiple Tubes and Tendons
Tendon-actuated concentric tube mechanisms combine the advantages of tendon-driven continuum robots and concentric tube robots while addressing their respective limitations. They overcome the restricted degrees of freedom often seen in tendon-driven designs and mitigate issues such as restricted curvatures associated with concentric tube robots. However, a complete and general mechanical model for these systems remains an open problem. In this work, we propose a Cosserat rod-based framework for modeling the general case of n concentric tubes, each actuated by mi tendons, where i = {1, . . . , n}. The model allows each tube to twist and elongate while enforcing a shared centerline for bending. We validate the proposed framework through experiments with two-tube and three-tube assemblies under various tendon routing configurations, achieving tip prediction errors < 4% of the robot’s total length. We further demonstrate the model’s generality by applying it to existing robots in the field, where maximum tip deviations remain around 5% of the total length. This model provides a foundation for accurate shape estimation and control of advanced tendon-actuated concentric tube robots.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. PP (3) , 1
A Comprehensive General Model of Tendon-Actuated Concentric Tube Robots with Multiple Tubes and Tendons
Tendon-actuated concentric tube mechanisms combine the advantages of tendon-driven continuum robots and concentric tube robots while addressing their respective limitations. They overcome the restricted degrees of freedom often seen in tendon-driven designs and mitigate issues such as restricted curvatures associated with concentric tube robots. However, a complete and general mechanical model for these systems remains an open problem. In this work, we propose a Cosserat rod-based framework for modeling the general case of n concentric tubes, each actuated by mi tendons, where i = {1, . . . , n}. The model allows each tube to twist and elongate while enforcing a shared centerline for bending. We validate the proposed framework through experiments with two-tube and three-tube assemblies under various tendon routing configurations, achieving tip prediction errors < 4% of the robot’s total length. We further demonstrate the model’s generality by applying it to existing robots in the field, where maximum tip deviations remain around 5% of the total length. This model provides a foundation for accurate shape estimation and control of advanced tendon-actuated concentric tube robots.
- 20 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (4) , 4505-4512
Tendon-Actuated Galvanometer Robot (TAGR) Towards Minimally Invasive Hybrid Surgical Laser Steering
Surgical lasers are becoming increasingly prevalent in minimally invasive procedures, as laser fibers are thin and flexible, allowing for precise targeting. The use of surgical lasers spans tissue manipulation, energy delivery (in laser interstitial thermal therapy), imaging (optical coherence tomography), and tumor identification. There are two primary methods for steering surgical lasers: fiber steering and free-beam steering using galvanometers. In practice, however, lasers must first traverse through complex anatomical structures, then the laser must be steered with high precision while the tool body avoids critical anatomy. In this letter, we develop a steerable surgical tool that combines both fiber and free-beam steering, the Tendon-Actuated Galvanometer Robot (TAGR). The proposed ball-chain (BC) robot can bend in 3D space, then utilizes a 2-DoF tendon-actuated galvanometer (TAG) at the end-effector to steer the laser on a surface while the robot body is static. Both BC kinematics and 2-DoF TAG laser kinematics models are presented and validated. Closed-loop PID control is implemented in both robot and laser steering, resulting in RMSE values of less than 2.5 mm and 3.7 mm for independent and hybrid steering, respectively. The novel hybrid laser steering system is then demonstrated within a phantom rib-cage model to showcase how novel hybrid laser steering can impact minimally invasive laser surgery.
- 20 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (4) , 4505-4512
Tendon-Actuated Galvanometer Robot (TAGR) Towards Minimally Invasive Hybrid Surgical Laser Steering
Surgical lasers are becoming increasingly prevalent in minimally invasive procedures, as laser fibers are thin and flexible, allowing for precise targeting. The use of surgical lasers spans tissue manipulation, energy delivery (in laser interstitial thermal therapy), imaging (optical coherence tomography), and tumor identification. There are two primary methods for steering surgical lasers: fiber steering and free-beam steering using galvanometers. In practice, however, lasers must first traverse through complex anatomical structures, then the laser must be steered with high precision while the tool body avoids critical anatomy. In this letter, we develop a steerable surgical tool that combines both fiber and free-beam steering, the Tendon-Actuated Galvanometer Robot (TAGR). The proposed ball-chain (BC) robot can bend in 3D space, then utilizes a 2-DoF tendon-actuated galvanometer (TAG) at the end-effector to steer the laser on a surface while the robot body is static. Both BC kinematics and 2-DoF TAG laser kinematics models are presented and validated. Closed-loop PID control is implemented in both robot and laser steering, resulting in RMSE values of less than 2.5 mm and 3.7 mm for independent and hybrid steering, respectively. The novel hybrid laser steering system is then demonstrated within a phantom rib-cage model to showcase how novel hybrid laser steering can impact minimally invasive laser surgery.
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 3047-3055
ExoNav: A Novel Robotic Steering and Latching Mechanism for Spinal Cord Stimulation Electrodes
Robotic steering mechanism can be useful in the placement of electrodes in spinal cord stimulation (SCS) procedures. This article introduces an innovative steering and latching mechanism called the ExoNav, designed for SCS electrodes. By applying magnetic locking in the robotic system, a noncontact stabilization is established at the robot's base to reduce tendon-sheath coupling effects that are common in continuum robots. A kinematic model has been developed and validated to predict the robot's behavior when subjected to tendon actuation. To broaden the analysis, a comparative assessment is performed by comparing robot behavior in an experimental setup involving a free base, with one stabilized by an external magnet. Finally, proof-of-concept trials with a surgeon demonstrate the capability of the ExoNav robot in phantom spinal cord models.
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (4) , 3047-3055
ExoNav: A Novel Robotic Steering and Latching Mechanism for Spinal Cord Stimulation Electrodes
Robotic steering mechanism can be useful in the placement of electrodes in spinal cord stimulation (SCS) procedures. This article introduces an innovative steering and latching mechanism called the ExoNav, designed for SCS electrodes. By applying magnetic locking in the robotic system, a noncontact stabilization is established at the robot's base to reduce tendon-sheath coupling effects that are common in continuum robots. A kinematic model has been developed and validated to predict the robot's behavior when subjected to tendon actuation. To broaden the analysis, a comparative assessment is performed by comparing robot behavior in an experimental setup involving a free base, with one stabilized by an external magnet. Finally, proof-of-concept trials with a surgeon demonstrate the capability of the ExoNav robot in phantom spinal cord models.
- 24 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (7) , 6464-6471
Towards a Tendon-Assisted Magnetically Steered (TAMS) Robotic Stylet for Brachytherapy
Interstitial brachytherapy requires up to 20 straight needles to surround and irradiate deep-seated tumors, but may offer sub-optimal radiation dosage in cases of advanced cancers. A steerable stylet can be used to guide the needle within the tissue, improving procedure accuracy and reducing the number of needles required for each operation. This work introduces the design of a novel tendon-assisted magnetically steered (TAMS) robotic stylet to steer commercially available brachytherapy needles. The dual-actuation modality (magnetic and tendon-driven) allows for increased bending compliance while retaining axial rigidity at extremely small diameters (OD: 1.4 mm), key properties for steering hollow needles from within their lumen. We also develop a two-tube Cosserat rod model that estimates the behavior of the TAMS robot and needle assembly under actuation from tendons, external magnetic fields, and finally combined magnet+tendon forces. We validate our model in free space and demonstrate the capability of the TAMS robot and dual-actuation modalities to steer brachytherapy needles to high curvatures inside phantom tissue.
- 24 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (7) , 6464-6471
Towards a Tendon-Assisted Magnetically Steered (TAMS) Robotic Stylet for Brachytherapy
Interstitial brachytherapy requires up to 20 straight needles to surround and irradiate deep-seated tumors, but may offer sub-optimal radiation dosage in cases of advanced cancers. A steerable stylet can be used to guide the needle within the tissue, improving procedure accuracy and reducing the number of needles required for each operation. This work introduces the design of a novel tendon-assisted magnetically steered (TAMS) robotic stylet to steer commercially available brachytherapy needles. The dual-actuation modality (magnetic and tendon-driven) allows for increased bending compliance while retaining axial rigidity at extremely small diameters (OD: 1.4 mm), key properties for steering hollow needles from within their lumen. We also develop a two-tube Cosserat rod model that estimates the behavior of the TAMS robot and needle assembly under actuation from tendons, external magnetic fields, and finally combined magnet+tendon forces. We validate our model in free space and demonstrate the capability of the TAMS robot and dual-actuation modalities to steer brachytherapy needles to high curvatures inside phantom tissue.