FZFaseeh Zaidi

Faseeh Zaidi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Faseeh Zaidi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Craig M. Goplen

    Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand

    3 shared publications
  • Jacob T. Munro

    Department of Surgery, University of Auckland, Auckland, New Zealand

    3 shared publications
  • Andrew P. Monk

    Department of Surgery, University of Auckland, Auckland, New Zealand

    2 shared publications
  • Michael Hanlon

    Department of Orthopaedic Surgery, Auckland City Hospital, Auckland, New Zealand

    2 shared publications
  • Scott M. Bolam

    Department of Surgery, University of Auckland, Auckland, New Zealand

    2 shared publications
  • A. Paul Monk

    Department of Surgery, University of Auckland, Auckland, New Zealand

    1 shared publication

Latest Publications

  • The impact of changing Coronal Plane Alignment of the Knee classification on early functional outcomes after primary robotic-assisted total knee arthroplasty

    by Faseeh Zaidi, Craig M. Goplen, Massoud Akbarshahi, Samuel J. MacDessi, Josh Petterwood, Peter McEwen, Jacob T. Munro, A. Paul Monk

    Aims: We aimed to determine the impact of changing a patient’s Coronal Plane Alignment of the Knee (CPAK) phenotype on early functional outcomes after robotic-assisted total knee arthroplasty (RA-TKA). Methods: We conducted a retrospective multicentre cohort study of 297 patients undergoing primary RA-TKA. Standardized pre- and postoperative long-leg radiographs were obtained. Radiological measures included the lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA). Pre- and postoperative CPAK classification was derived by determining the arithmetic hip-knee-ankle (HKA) angle and joint line obliquity (JLO). Oxford Knee Scores (OKSs) were assessed at preoperative baseline and at three months, six months, and one year postoperatively. We also investigated the isolated impact of changes in LDFA and MPTA on OKS. Results: Preoperatively, the most common classification was CPAK type II (30.0%; n = 89), followed by type I (27.6%; n = 82). Postoperatively, the majority of patients were CPAK type V (30.0%; n = 89), followed by type IV and type II. Overall, 30.6% (n = 91) of patients remained in the same preoperative CPAK classification, while 62.3% (n = 185) shifted by one CPAK classification and 6.4% (n = 19) moved two phenotypes following RA-TKA. Patients who moved across two CPAK phenotypes after RA-TKA demonstrated significantly smaller improvements in OKS at three months (p = 0.008) and six months (p = 0.036) compared with those who remained in the same CPAK phenotype. Patients with LDFA changes in excess of 4° from the native value demonstrated the smallest improvement in mean three-month (7.14 (SD 9.9)) and six-month (10.95 (SD 7.0)) OKS compared with all other groups. Conclusion: In this exploratory analysis, altering coronal alignment across two CPAK classifications after RA-TKA was associated with lower early functional outcomes as measured by OKS at three months and six months, though this finding was based on a small subgroup (n = 19) and warrants further investigation in larger cohorts. Furthermore, femoral coronal deviation in excess of 4° from native alignment appears to have a greater negative impact on functional outcomes than equivalent tibial changes. Cite this article: Bone Joint J 2026;108-B(10):1238–1246.

  • Have we come to the end of the patient-reported outcome measure (PROM)?

    by Faseeh Zaidi, Scott M. Bolam, Craig Michael Goplen, Ted Yeung, Michael Hanlon, Jacob T. Munro, Thor F. Besier, Andrew P. Monk

    Aims: The purpose of this study was to evaluate early outcomes of patients who underwent robotic-assisted total knee arthroplasty (RA-TKA) and conventional TKA using wearable sensors and traditional patient-reported outcome measures (PROMs). Methods: This was a prospective, matched, parallel cohort study of 100 patients with symptomatic end-stage knee osteoarthritis undergoing primary TKA (44 RA-TKA, 56 conventional TKA). Functional outcomes were assessed using wearable inertial measurement units (IMUs). IMU-based outcomes included impact load, impact asymmetry, maximum knee flexion angle, and bone stimulus. PROMs, including Oxford Knee Score, EuroQol five-dimension five-level questionnaire, EuroQol visual analogue scale, and Forgotten Joint Score, were evaluated at preoperative baseline and weeks 2 to 6 postoperatively. Results: By postoperative week 6, RA-TKA patients showed improved function compared with the conventional TKA group, with increased maximum knee flexion angle (118° (SD 6.6°) vs 113° (SD 5.4°); p = 0.038), improved symmetry with regard to limb loading (82.3% (SD 16.1) vs 22.4% (SD 9.5); p < 0.001), increased cumulative impact load (146.6% (SD 16.7) vs 37% (SD 8.1); p < 0.001), and increased bone stimulus (25.1% vs 13.6%; p = 0.003). RA-TKA patients demonstrated an earlier return to symmetrical limb loading compared with conventional TKA by postoperative week 3. There were no significant differences in PROMs between the two groups at any timepoint. Conclusion: RA-TKAs using personalized alignment were associated with faster return of symmetrical gait and improved range of motion when assessed using IMUs compared with conventional TKA, which were not detected by traditional PROMs during the early postoperative period. Cite this article: Bone Joint J 2026;108-B(4):478–489.


  • Open Access

    High in‐vivo accuracy of a novel robotic‐arm‐assisted system for total knee arthroplasty

    by Faseeh Zaidi, Craig M. Goplen, Connor Fitz‐Gerald, Scott M. Bolam, Michael Hanlon, Jacob T. Munro, Andrew P. Monk

    Purpose: Robotic‐assisted total knee arthroplasty (TKA) has been shown to improve the accuracy and precision of bony resections and implant position. However, the in vivo accuracy of the full surgical workflow has not been widely reported. The primary objective of this study is to determine the accuracy and precision of a robotic‐arm‐assisted system throughout the intraoperative workflow.Methods: This was a retrospective cohort study of adult patients who underwent primary TKA with various workflows and alignment targets by three arthroplasty‐trained surgeons with previous experience using the ROSA® Knee System (Zimmer Biomet) over a 3‐month follow‐up period. Accuracy and precision were determined by measuring the difference between various workflow time points, including the final preoperative plan (PP), robot‐validated (RV) resection angle and postoperative radiographs (PR). The absolute mean difference between the measurements determined accuracy, and the standard deviation represented precision. The lateral distal femoral angle, medial proximal tibial angle, femoral flexion angle and tibial slope were measured on postoperative coronal long‐leg radiographs and true short‐leg lateral radiographs.Results: A total of 77 patients were included in the final analyses. The accuracy for the coronal femoral angle was 1.62 ± 1.11°, 0.75 ± 0.79° and 1.96 ± 1.29° for the differences between PP and PR, PP and RV and RV and PR. The tibial coronal accuracy was 1.44 ± 1.03°, 0.81 ± 0.67° and 1.57 ± 1.14° for PP/PR, PP/RV and RV/PR, respectively. Femoral flexion accuracy was 1.39 ± 1.05°, 0.83 ± 0.59° and 1.81 ± 1.21° for PP/PR, PP/RV and RV/PR, respectively. Tibial slope accuracy was 0.99 ± 0.72°, 1.19 ± 0.87° and 1.63 ± 1.11°, respectively. The proportion of patients within 3° was 93.2%, 95.3%, 97.3% and 94.6% for the distal femur, proximal tibia, femoral flexion and tibial slope angles when the final intraoperative plan was compared to PRs. No patients had a postoperative complication at the final follow‐up.Conclusions: The ROSA Knee System has acceptable accuracy and precision of coronal and sagittal plane resections with few outliers at various steps throughout the platform's entire workflow in vivo.Level of Evidence: Level III.


  • REMOTE EVALUATION OF POSTOPERATIVE OUTCOMES USING WEARABLE SENSORS COMPARING ROBOTIC-ASSISTED AND CONVENTIONAL KNEE ARTHROPLASTY

    by F. Zaidi, S.M. Bolam, T.C. Yeung, T.F. Besier, M. Hanlon, J.T. Munro, A.P. Monk

    Patient-reported outcome measures (PROMs) have failed to highlight differences in function or outcome when comparing knee replacement designs and implantation techniques. Ankle-worn inertial measurement units (IMUs) can be used to remotely measure and monitor the bi-lateral impact load of patients, augmenting traditional PROMs with objective data. The aim of this study was to compare IMU-based impact loads with PROMs in patients who had undergone conventional total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA), and robotic-assisted TKA (RA-TKA).77 patients undergoing primary knee arthroplasty (29 RA-TKA, 37 TKA, and 11 UKA) for osteoarthritis were prospectively enrolled. Remote patient monitoring was performed pre-operatively, then weekly from post-operative weeks two to six using ankle-worn IMUs and PROMs. IMU-based outcomes included: cumulative impact load, bone stimulus, and impact load asymmetry. PROMs scores included: Oxford Knee Score (OKS), EuroQol Five-dimension with EuroQol visual analogue scale, and the Forgotten Joint Score.On average, patients showed improved impact load asymmetry by 67% (p=0.001), bone stimulus by 41% (p<0.001), and cumulative impact load by 121% (p=0.035) between post-operative week two and six. Differences in IMU-based outcomes were observed in the initial six weeks post-operatively between surgical procedures. The mean change scores for OKS were 7.5 (RA-TKA), 11.4 (TKA), and 11.2 (UKA) over the early post-operative period (p=0.144). Improvements in OKS were consistent with IMU outcomes in the RA-TKA group, however, conventional TKA and UKA groups did not reflect the same trend in improvement as OKS, demonstrating a functional decline.Our data illustrate that PROMs do not necessarily align with patient function, with some patients reporting good PROMs, yet show a decline in cumulative impact load or load asymmetry. These data also provide evidence for a difference in the functional outcome of TKA and UKA patients that might be overlooked by using PROMs alone.