Saliha Erdem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Saliha Erdem has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Chloe Kharsa
Division of Cardiology, Houston Methodist DeBakey Heart & Vascular Institute, Houston Methodist Hospital, Houston, Texas
2 shared publicationsAbou Zeid Karl
Division of Cardiology, Houston Methodist DeBakey Heart & Vascular Institute, Houston Methodist Hospital, Houston, Texas
1 shared publicationAnas Hashem
Division of Cardiology, Houston Methodist DeBakey Heart & Vascular Institute, Houston Methodist Hospital, Houston, Texas
1 shared publication- Ashish Kumar
Department of Internal Medicine, Cleveland Clinic Akron General, Akron, OH 44307, USA
1 shared publication - Dhruvil Ashishkumar Patel
Department of Internal Medicine, University of Chicago Medical Center, Chicago, Illinois, US
1 shared publication - Gerald Koenig
Henry Ford Heart and Vascular Institute, Detroit, MI 48202, USA
1 shared publication
Latest Publications
- Open Access
- 27 August 2026
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 5 (10) , 105618
Sex Differences in Referral Timing for Mitral Transcatheter Edge-to-Edge Repair: A Retrospective Cohort Study
- 27 August 2026
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 5 (10) , 105618
Open AccessSex Differences in Referral Timing for Mitral Transcatheter Edge-to-Edge Repair: A Retrospective Cohort Study
- Open Access
- 12 August 2026
- Published by Elsevier in JACC: Advances
- Vol. 5 (11)
Women in the Leadership of Interventional Structural Heart Disease Trials
- 12 August 2026
- Published by Elsevier in JACC: Advances
- Vol. 5 (11)
Open AccessWomen in the Leadership of Interventional Structural Heart Disease Trials
- 24 November 2025
- Vol. 19 (2) , 3-4
Five-year Outcomes of Transcatheter Aortic Valve Replacement Versus Surgery in Low-risk Aortic Stenosis: Insights from the Evolut Low Risk Trial
The Evolut Low Risk trial (Transcatheter Aortic Valve Replacement With the Medtronic Transcatheter Aortic Valve Replacement System In Patients at Low Risk for Surgical Aortic Valve Replacement; ClinicalTrials.gov identifier: NCT02701283) provides reassuring evidence that transcatheter aortic valve replacement remains non-inferior to surgery at 5-year follow-up with regard to mortality and disabling stroke in low-risk patients. Valve performance, durability and quality-of-life improvements were excellent in both groups.
- 24 November 2025
- Vol. 19 (2) , 3-4
Five-year Outcomes of Transcatheter Aortic Valve Replacement Versus Surgery in Low-risk Aortic Stenosis: Insights from the Evolut Low Risk Trial
The Evolut Low Risk trial (Transcatheter Aortic Valve Replacement With the Medtronic Transcatheter Aortic Valve Replacement System In Patients at Low Risk for Surgical Aortic Valve Replacement; ClinicalTrials.gov identifier: NCT02701283) provides reassuring evidence that transcatheter aortic valve replacement remains non-inferior to surgery at 5-year follow-up with regard to mortality and disabling stroke in low-risk patients. Valve performance, durability and quality-of-life improvements were excellent in both groups.
- Open Access
- 12 August 2025
- Published by Houston Methodist DeBakey Heart & Vascular Center in Methodist DeBakey Cardiovascular Journal
- Vol. 21 (4) , 14-25
Temporary Mechanical Circulatory Support for Acute Myocardial Infarction Cardiogenic Shock
Cardiogenic shock (CS) complicating acute myocardial infarction (AMI) remains a critical clinical challenge associated with high morbidity and mortality. Temporary mechanical circulatory support (tMCS) devices can stabilize hemodynamics, improve cardiac output, and enhance survival, thereby continuing to be more favorable with operators. This review summarizes the pathophysiology of AMI-CS and examines the evidence informing recommendations for tMCS device implementation—specifically the intra-aortic balloon pump, Impella (Abiomed/J&J MedTech), TandemHeart™ (LivaNova, Inc.), and venoarterial extracorporeal membrane oxygenation—with a particular focus on clinical trial data and recent guideline recommendations to assist operators in implementing decision-making.
- 12 August 2025
- Published by Houston Methodist DeBakey Heart & Vascular Center in Methodist DeBakey Cardiovascular Journal
- Vol. 21 (4) , 14-25
Open AccessTemporary Mechanical Circulatory Support for Acute Myocardial Infarction Cardiogenic Shock
Cardiogenic shock (CS) complicating acute myocardial infarction (AMI) remains a critical clinical challenge associated with high morbidity and mortality. Temporary mechanical circulatory support (tMCS) devices can stabilize hemodynamics, improve cardiac output, and enhance survival, thereby continuing to be more favorable with operators. This review summarizes the pathophysiology of AMI-CS and examines the evidence informing recommendations for tMCS device implementation—specifically the intra-aortic balloon pump, Impella (Abiomed/J&J MedTech), TandemHeart™ (LivaNova, Inc.), and venoarterial extracorporeal membrane oxygenation—with a particular focus on clinical trial data and recent guideline recommendations to assist operators in implementing decision-making.
- Open Access
- 15 May 2025
- Published by Houston Methodist DeBakey Heart & Vascular Center in Methodist DeBakey Cardiovascular Journal
- Vol. 21 (3) , 106-108
Uncovering a Windsock Aneurysm of the Interventricular Septum: An Incidental Structural Abnormality
We present a case of a 75-year-old female with a history of idiopathic small fiber neuropathy, essential hypertension, and heterozygous familial hypercholesterolemia who was evaluated for exertional dyspnea and fatigue. Coronary computed tomography angiography demonstrated a 16-mm wide-neck windsock aneurysm of the interventricular septum along with a patent foramen ovale and left-to-right shunting. This case underscores the role of advanced cardiac imaging in detecting rare structural abnormalities.
- 15 May 2025
- Published by Houston Methodist DeBakey Heart & Vascular Center in Methodist DeBakey Cardiovascular Journal
- Vol. 21 (3) , 106-108
Open AccessUncovering a Windsock Aneurysm of the Interventricular Septum: An Incidental Structural Abnormality
We present a case of a 75-year-old female with a history of idiopathic small fiber neuropathy, essential hypertension, and heterozygous familial hypercholesterolemia who was evaluated for exertional dyspnea and fatigue. Coronary computed tomography angiography demonstrated a 16-mm wide-neck windsock aneurysm of the interventricular septum along with a patent foramen ovale and left-to-right shunting. This case underscores the role of advanced cardiac imaging in detecting rare structural abnormalities.
- Open Access
- 28 May 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (11) , 3161
Mechanical Circulatory Support Devices in Patients with High-Risk Pulmonary Embolism
Pulmonary embolism (PE) is a common acute cardiovascular condition. Within this review, we discuss the incidence, pathophysiology, and treatment options for patients with high-risk and massive pulmonary embolisms. In particular, we focus on the role of mechanical circulatory support devices and their possible therapeutic benefits in patients who are unresponsive to standard therapeutic options. Moreover, attention is given to device selection criteria, weaning protocols, and complication mitigation strategies. Finally, we underscore the necessity for more comprehensive studies to corroborate the benefits and safety of MCS devices in PE management.
- 28 May 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (11) , 3161
Open AccessMechanical Circulatory Support Devices in Patients with High-Risk Pulmonary Embolism
Pulmonary embolism (PE) is a common acute cardiovascular condition. Within this review, we discuss the incidence, pathophysiology, and treatment options for patients with high-risk and massive pulmonary embolisms. In particular, we focus on the role of mechanical circulatory support devices and their possible therapeutic benefits in patients who are unresponsive to standard therapeutic options. Moreover, attention is given to device selection criteria, weaning protocols, and complication mitigation strategies. Finally, we underscore the necessity for more comprehensive studies to corroborate the benefits and safety of MCS devices in PE management.
- Open Access
- 1 January 2023
- Published by Texas Medical Center Library in Journal of Shock and Hemodynamics
- Vol. 2 (1) , 9
An Unusual Case of Refractory Hypoxia: The Many Ways of Providing Oxygen
This case report outlines the complex clinical course of a 26-year-old female patient who presented with altered mental status after an N-methyl-3,4-methylenedioxy-amphetamine overdose. The patient exhibited profound hemodynamic instability and respiratory failure. She subsequently developed shock, necessitating advanced life support measures, including veno-venous extracorporeal membrane oxygenation with a dual lumen right atrium to pulmonary artery cannula (ProtekDuo; LivaNova, London, UK) and Quadrox Oxygenator (Getinge, Wayne, NJ) system. This resulted in worsening hypoxemia, which was attributed to an increased left ventricular preload. In response, an intra-aortic balloon pump was used to decrease the left ventricle’s afterload. After balloon placement, the patient’s hemodynamic instability and refractory hypoxia improved. We discuss the clinical challenges encountered and the multidisciplinary approach used to manage this critically ill patient successfully.
- 1 January 2023
- Published by Texas Medical Center Library in Journal of Shock and Hemodynamics
- Vol. 2 (1) , 9
Open AccessAn Unusual Case of Refractory Hypoxia: The Many Ways of Providing Oxygen
This case report outlines the complex clinical course of a 26-year-old female patient who presented with altered mental status after an N-methyl-3,4-methylenedioxy-amphetamine overdose. The patient exhibited profound hemodynamic instability and respiratory failure. She subsequently developed shock, necessitating advanced life support measures, including veno-venous extracorporeal membrane oxygenation with a dual lumen right atrium to pulmonary artery cannula (ProtekDuo; LivaNova, London, UK) and Quadrox Oxygenator (Getinge, Wayne, NJ) system. This resulted in worsening hypoxemia, which was attributed to an increased left ventricular preload. In response, an intra-aortic balloon pump was used to decrease the left ventricle’s afterload. After balloon placement, the patient’s hemodynamic instability and refractory hypoxia improved. We discuss the clinical challenges encountered and the multidisciplinary approach used to manage this critically ill patient successfully.