AWAdrian Wajer

Adrian Wajer

*This is an algorithmically generated author record based on publicly available information.

Adrian Wajer has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing Image Quality in Dental-Maxillofacial CBCT: The Impact of Iterative Reconstruction and AI on Noise Reduction—A Systematic Review

    by Róża Wajer, Pawel Dabrowski-Tumanski, Adrian Wajer, Natalia Kazimierczak, Zbigniew Serafin, Wojciech Kazimierczak

    Background: This systematic review evaluates articles investigating the use of iterative reconstruction (IR) algorithms and artificial intelligence (AI)-based noise reduction techniques to improve the quality of oral CBCT images. Materials and Methods: A detailed search was performed across PubMed, Scopus, Web of Science, ScienceDirect, and Embase databases. The inclusion criteria were prospective or retrospective studies with IR and AI for CBCT images, studies in which the image quality was statistically assessed, studies on humans, and studies published in peer-reviewed journals in English. Quality assessment was performed independently by two authors, and the conflicts were resolved by the third expert. For bias assessment, the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool was used for bias assessment. Material: A total of eleven studies were included, analyzing a range of IR and AI methods designed to reduce noise and artifacts in CBCT images. Results: A statistically significant improvement in CBCT image quality parameters was achieved by the algorithms used in each of the articles we reviewed. The most commonly used image quality measures were peak signal-to-noise ratio (PSNR) and contrast-to-noise ratio (CNR). The most significant increase in PSNR was demonstrated by Ylisiurua et al. and Vestergaard et al., who reported an increase in this parameter of more than 30% for both deep learning (DL) techniques used. Another subcategory used to improve the quality of CBCT images is the reconstruction of synthetic computed tomography (sCT) images using AI. The use of sCT allowed an increase in PSNR ranging from 17% to 30%. For the more traditional methods, FBP and iterative reconstructions, there was an improvement in the PSNR parameter but not as high, ranging from 3% to 13%. Among the research papers evaluating the CNR parameter, an improvement of 17% to 29% was achieved. Conclusions: The use of AI and IR can significantly improve the quality of oral CBCT images by reducing image noise.


  • Open Access

    Endodontic Treatment Outcomes in Cone Beam Computed Tomography Images—Assessment of the Diagnostic Accuracy of AI

    by Wojciech Kazimierczak, Natalia Kazimierczak, Julien Issa, Róża Wajer, Adrian Wajer, Sandra Kalka, Zbigniew Serafin

    Background/Objectives: The aim of this study was to assess the diagnostic accuracy of the AI-driven platform Diagnocat for evaluating endodontic treatment outcomes using cone beam computed tomography (CBCT) images. Methods: A total of 55 consecutive patients (15 males and 40 females, aged 12–70 years) referred for CBCT imaging were included. CBCT images were analyzed using Diagnocat’s AI platform, which assessed parameters such as the probability of filling, adequate obturation, adequate density, overfilling, voids in filling, short filling, and root canal number. The images were also evaluated by two experienced human readers. Diagnostic accuracy metrics (accuracy, precision, recall, and F1 score) were assessed and compared to the readers’ consensus, which served as the reference standard. Results: The AI platform demonstrated high diagnostic accuracy for most parameters, with perfect scores for the probability of filling (accuracy, precision, recall, F1 = 100%). Adequate obturation showed moderate performance (accuracy = 84.1%, precision = 66.7%, recall = 92.3%, and F1 = 77.4%). Adequate density (accuracy = 95.5%, precision, recall, and F1 = 97.2%), overfilling (accuracy = 95.5%, precision = 86.7%, recall = 100%, and F1 = 92.9%), and short fillings (accuracy = 95.5%, precision = 100%, recall = 86.7%, and F1 = 92.9%) also exhibited strong performance. The performance of AI for voids in filling detection (accuracy = 88.6%, precision = 88.9%, recall = 66.7%, and F1 = 76.2%) highlighted areas for improvement. Conclusions: The AI platform Diagnocat showed high diagnostic accuracy in evaluating endodontic treatment outcomes using CBCT images, indicating its potential as a valuable tool in dental radiology.


  • Open Access

    The Impact of AI on Metal Artifacts in CBCT Oral Cavity Imaging

    by Róża Wajer, Adrian Wajer, Natalia Kazimierczak, Justyna Wilamowska, Zbigniew Serafin

    Objective: This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. Materials and Methods: This retrospective study included 70 patients, 61 of whom were analyzed after excluding those with severe motion artifacts. CBCT scans, performed using a Hyperion X9 PRO 13 × 10 CBCT machine, included images with dental implants, amalgam fillings, orthodontic appliances, root canal fillings, and crowns. Images were processed with the ClariCT.AI deep learning model (DLM) for noise reduction. Objective image quality was assessed using metrics such as the differentiation between voxel values (ΔVVs), the artifact index (AIx), and the contrast-to-noise ratio (CNR). Subjective assessments were performed by two experienced readers, who rated overall image quality and artifact intensity on predefined scales. Results: Compared with native images, DLM reconstructions significantly reduced the AIx and increased the CNR (p < 0.001), indicating improved image clarity and artifact reduction. Subjective assessments also favored DLM images, with higher ratings for overall image quality and lower artifact intensity (p < 0.001). However, the ΔVV values were similar between the native and DLM images, indicating that while the DLM reduced noise, it maintained the overall density distribution. Orthodontic appliances produced the most pronounced artifacts, while implants generated the least. Conclusions: AI-based noise reduction using ClariCT.AI significantly enhances CBCT image quality by reducing noise and metal artifacts, thereby improving diagnostic accuracy and treatment planning. Further research with larger, multicenter cohorts is recommended to validate these findings.


  • Open Access

    The Impact of AI on Metal Artifacts in CBCT Oral Cavity Imaging

    by Róża Wajer, Adrian Wajer, Natalia Kazimierczak, Justyna Wilamowska, Zbigniew Serafin

    Objective: This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. Materials and Methods: This retrospective study included 70 patients, 61 of whom were analyzed after excluding those with severe motion artifacts. CBCT scans, performed using a Hyperion X9 PRO 13 × 10 CBCT machine, included images with dental implants, amalgam fillings, orthodontic appliances, root canal fillings, and crowns. Images were processed with ClariCT. AI deep learning model (DLM) for noise reduction. Objective image quality was assessed using metrics such as the differentiation between voxel values (ΔVVs), the artifact index (AIx), and the contrast-to-noise ratio (CNR). Subjective assessments were performed by two experienced readers, who rated overall image quality and artifact intensity on predefined scales. Results: Compared with native images, DLM reconstructions significantly reduced the AIx and increased the CNR (p<0.001), indicating improved image clarity and artifact reduction. Subjective assessments also favored DLM images, with higher ratings for overall image quality and lower artifact intensity (p<0.001). However, the ΔVV values were similar between the native and DLM images, indicating that while the DLM reduced noise, it maintained the overall density distribution. Orthodontic appliances produced the most pronounced artifacts, while implants generated the least. Conclusion: AI-based noise reduction using ClariCT. AI significantly enhances CBCT image quality by reducing noise and metal artifacts, thereby improving diagnostic accuracy and treatment planning. Further research with larger, multicenter cohorts is recommended to validate these findings.