KSKonstantin Sergeevich Sergeev

Konstantin Sergeevich Sergeev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Konstantin Sergeevich Sergeev has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Endovascular–microsurgical treatment of hypervascular spinal tumors: influence of cervical, thoracic, and lumbar vascular anatomy on embolization decisions and primary clinical outcomes (25-case series)

    by Dmitry E. Zakondyrin, Eduard E. Rostorguev, Amirhossein Hosseini, Saidi S. Gaibov, Konstantin S. Sergeev, Dmiriy Khrupa, Myasnik A. Arabhanyan, Vladimir Malchevskiy

    Objective To assess whether preoperative spinal angiography with endovascular embolization followed by microsurgical resection is technically feasible and safe for hypervascular spinal tumors, and to examine how cervical, thoracic, and lumbar vascular anatomy influences feasibility. Methods We retrospectively reviewed 25 patients treated from 2017 to 2025 at two centers (14 men, 11 women; mean age 53 years) with hypervascular tumors involving the cervical (n = 3), thoracic (n = 15), lumbar and sacral (n = 7) spine. All underwent preoperative angiography (DSA)-embolization (within the same procedure if technically possible). We recorded whether embolization could be safely performed and any embolization-related complications; we also graded angiographic devascularization (devascularization grade, DG) and operative estimated blood loss (EBL). Selective or super-selective embolization was performed when arterial anatomy allowed safe catheterization, and surgery followed within 24–48 h. Results Embolization was feasible in 23/25 patients (92%): thoracic 15/15 (100%), lumbar 6/6 (100%), sacral 1/1 (100%), and cervical 1/3 (33%). Two cervical RCC (renal cell carcinoma) metastases were not embolized because multiple short feeders shared trunks with radiculomedullary (spinal cord–supplying) arteries, precluding safe super-selective access. Among embolized cases, super-selective feeder occlusion was performed in 5/23 (21.7%) and segmental-vessel embolization in 18/23 (78.3%) using precipitating hydrophobic injectable liquid (PHIL), coils, and n-butyl cyanoacrylate (NBCA). High-grade devascularization (DG2–3) was achieved in all embolized cases, and completion angiography showed no or minimal residual tumor blush. There were no permanent embolization-related neurological deficits (0/23); one transient ischemic event occurred (1/23, 4.3%; vertebrobasilar ischemia in a C2 aneurysmal bone cyst) with full recovery. Mean estimated blood loss was 650 mL (median 600; range 400–800 mL. Differences in mean EBL between subsets of RCC and non-RCC tumors were statistically unsignificant, Correlations between DG and EBL was not identified. Conclusion A coordinated endovascular–surgical pathway achieved high embolization feasibility with no permanent embolization-related neurological complications, and no postoperative neurological deterioration in this cohort. Feasibility limitations were concentrated in the cervical spine, where short, shared feeders involving spinal cord–supplying arteries can preclude safe embolization. Limitations include retrospective design, small cohort with few cervical cases, and heterogeneous tumors/embolic agents; prospective studies with standardized devascularization and functional outcome metrics are warranted.

  • Open Access

    Analysis of epidemiological indicators, hospital treatment, the nature and type of spinal injuries in adult patients treated at a level I trauma center

    by Aleksei Olegovich Farion, Roman Vladimirovich Paskov, Konstantin Sergeevich Sergeev, Alexander Yur’Evich Bazarov, Aleksey Nicolaevich Nicolaevich Prokopev, Semur Ilkham Ogly Dadashev

    BACKGROUND: Spinal cord injury is a leading cause of disability in the adult population. Although spinal cord injuries represent a small proportion of trauma cases, they require special attention due to poor functional outcomes with serious negative socio-economic consequences. AIM: To analyse demographic data, mechanism, location and type of injury in patients with spinal fractures treated at a level I trauma centre in Tyumen over a five-year period. MATERIALS AND METHODS: We retrospectively analysed the medical records of all patients with spinal fractures who were treated at the State Budget Institution of Tuymen Regional Clinical Hospital No. 2 between 2018 and 2022. RESULTS: Spinal fractures were diagnosed in 1521 patients, i.e. 35.4 cases per 100,000 population per year; 5.5% had complicated fractures. The mean age of the injured was 53.5±12.5 years, and the majority of the patients were men (54.3%). The main cause of spinal fractures was falls — 68.0%; in the age group over 65 years, falls from own height (2 m) predominated — 49.6%. Road traffic accidents were the cause of injury in 18.2% of patients and were more common in the 25–34 age group. Injuries to the L1 vertebra (21.0%) were the most common in terms of location, with single fractures occurring in 75.1% of cases. CONCLUSION: During the five-year follow-up period, there was an increase in the number of spinal fractures. In addition, there was an annual increase in the number of spinal fractures in the over-65s, which was higher than in younger patients. Despite this increase, a significant number of spinal fractures continue to be diagnosed in the 35–64 age group. This study could help predict and improve the prevention and treatment of spinal fractures.


  • External Dynamic Apparatus Correction in Rigid Posttraumatic Spinal De-formations Engineering and Clinical Aspects

    by Konstantin S Sergeev, Roman V Pas’Kov, Valery V Piven

    Study design: The authors define most dangerous sections and calculate the stresses arising in the parts of the external fixation device. They configure external fixation devices taking into account the obtained results and use them in medical practice. Objective: the development of an apparatus correction technique for the treatment of spinal deformations. Summary of background data: standard methods of rigid deformation correction are technically complicated and high-costly; there are also possible formidable intraoperative complications. Authors consider a variant of apparatus external correction as an alternative to the known methods, which is devoid of the aforementioned disadvantages. Methods: The authors use theoretical and experimental research methods. The theoretical deductions are confirmed experimentally during clinical trials. Clinical studies were evaluated using ray-based diagnostic procedures, computed tomography, and patient interviewing using the Oswestry Disability Index and visual analogue scale. Results: The calculations showed that in case of one-sided point load, the stresses arising in the dangerous section of screws-rods from that load can reach 60 - 70% of the total stresses in the device nodes. During clinical testing it was established that external apparatus correction leads to normalization of anatomical relationships in the area of damaged segments, normalization of the spinal column axis, and reduction of pain; it does not preclude the use of dorsal internal puncture fixation. Conclusions: It is advisable to load the structural element of the external spinal fixation device in a skew-symmetric pattern, applying distraction and compression forces to the transverse plate on both sides along parallel straight lines in opposite directions. Apparatus external fixation makes it possible to perform a complete correction of rigid deformations without releasing the supporting structures, to control the level of neurological dis-orders, to simplify the technique of internal fixation operations, to use the minimally invasive procedure for the installation of the internal pedicle fixator.

  • Open Access

    The substantiation of the elastic–viscoplastic model of the human spine for modeling the correction process of kyphoscoliotic deformation

    by KonstantinS Sergeev, ValeryV Piven

    Y the spinal model as an elastic viscoplastic body for further mathematical modeling of the process of spine correction and search for its optimal conditions. Methodology: The leading approach to the study of this problem is the development of techniques for the surgical treatment of deformities of the vertebral column with the aid of an external fixation device for the spine, providing for a rigid connection of the elements of the apparatus with each other and with the spine. The rigid connection between the elements of the external fixation device increases the degree of static indeterminacy of the design, which leads to the occurrence of additional dangerous stresses in the details of the apparatus and in the vertebrae. The control actions in such devices do not provide an adequate result for the process of correction of the vertebral column. Results: The main result is the substantiation of the spine model as an elastic viscoplastic body. This will allow more detailed consideration of the medical and biological features of the spine and the physical and mechanical properties of human bone and soft tissues. The proposed model will allow developing an adaptive design of the device, taking into account specific features of the organism and more effectively managing the correction process. Value: The materials of the article can be useful for scientists, doctors and specialists in conducting scientific research on the problem of spine deformation correction and the development of appropriate technical means....