Gennaro Pipino
Gennaro Pipino has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alessio Giai Via
Orthopaedic and Traumatology Unit, Department of Emergency and Acceptance, Azienda Ospedaliera San Camillo – Forlanin, Rome, Italy
2 shared publications - Anzano Francesco
Department of Orthopaedic and Trauma Surgery, A.O. San Camillo-Forlanini, Rome, Italy
1 shared publication - Carmelo D’ARrigo
ASL Roma 4, 00053 Civitavecchia, Italy
1 shared publication - Filippo Migliorini
Department of Trauma and Reconstructive Surgery, University Hospital of Halle, Martin-Luther University Halle-Wittenberg, Halle (Saale), Germany
1 shared publication - Francesco Oliva
Department of Sports Traumatology, Università Telematica San Raffaele, Rome, Italy
1 shared publication - Giovanna Fidone
Department of Orthopaedic and Trauma Surgery, A.O. San Camillo-Forlanini, Rome, Italy
1 shared publication
Latest Publications
- Open Access
- 14 March 2026
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 21 (1)
Third-generation cryotherapy reduces time to surgery and local complications in patients with ankle fractures: a prospective randomised controlled trial
Background: Ankle fractures are common, and cryotherapy is routinely used to reduce pain, swelling and local skin complications, both before and after surgery. The aim of this study is to report the results with the use of pre-operative third-generation cryotherapy (Z-One ® , Zamar, Italy) in the management of patients with ankle fractures. We investigated the time to surgery, pain, opioid intake, and local skin complications. Methods: 169 patients with ankle fracture were randomised into two groups, the cryotherapy group (89 patients) and the control group (C: 80 patients). The time-to-surgery, Visual Analogue Scale (VAS) and the analgesic drug demands (Morphine Sulfate 10 mg/ml solution for injection) were recorded. The development of skin complications was assessed on a daily basis. BMI and the number of cigarettes smoked were also recorded. Results: The mean time-to-surgery was shorter in patients treated with cryotherapy compared to the control group (34.78 h vs. 91.44 h, p < 0.001). Significant differences between treatments and controls were found for VAS, morphine intake (number of vials), and skin complications. The mean preoperatory VAS and morphine consumption were lower in the cryotherapy group compared to controls (mean VAS 2.04 vs. 5.9, mean morphine consumption 0.1 mg vs. 0.83 mg). In the cryotherapy group, 4.5% of patients developed a skin complication compared to 28.7% of the control group; 85% of skin-related problems occurred in the non-cryotherapy group ( p < 0.001). Conclusion: Preoperative third-generation cryotherapy is effective in reducing time to surgery, preoperative pain, and opioid intake in patients hospitalised for ankle fractures. It is also effective in reducing the occurrence of skin complications. No major complications related to the use of the device were reported. Third-generation cryotherapy is useful in the perioperative management of patients necessitating surgery for ankle fractures. Clinical Trial Registration NCT06396364. Level of evidence I (RCT).
- 14 March 2026
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 21 (1)
Open AccessThird-generation cryotherapy reduces time to surgery and local complications in patients with ankle fractures: a prospective randomised controlled trial
Background: Ankle fractures are common, and cryotherapy is routinely used to reduce pain, swelling and local skin complications, both before and after surgery. The aim of this study is to report the results with the use of pre-operative third-generation cryotherapy (Z-One ® , Zamar, Italy) in the management of patients with ankle fractures. We investigated the time to surgery, pain, opioid intake, and local skin complications. Methods: 169 patients with ankle fracture were randomised into two groups, the cryotherapy group (89 patients) and the control group (C: 80 patients). The time-to-surgery, Visual Analogue Scale (VAS) and the analgesic drug demands (Morphine Sulfate 10 mg/ml solution for injection) were recorded. The development of skin complications was assessed on a daily basis. BMI and the number of cigarettes smoked were also recorded. Results: The mean time-to-surgery was shorter in patients treated with cryotherapy compared to the control group (34.78 h vs. 91.44 h, p < 0.001). Significant differences between treatments and controls were found for VAS, morphine intake (number of vials), and skin complications. The mean preoperatory VAS and morphine consumption were lower in the cryotherapy group compared to controls (mean VAS 2.04 vs. 5.9, mean morphine consumption 0.1 mg vs. 0.83 mg). In the cryotherapy group, 4.5% of patients developed a skin complication compared to 28.7% of the control group; 85% of skin-related problems occurred in the non-cryotherapy group ( p < 0.001). Conclusion: Preoperative third-generation cryotherapy is effective in reducing time to surgery, preoperative pain, and opioid intake in patients hospitalised for ankle fractures. It is also effective in reducing the occurrence of skin complications. No major complications related to the use of the device were reported. Third-generation cryotherapy is useful in the perioperative management of patients necessitating surgery for ankle fractures. Clinical Trial Registration NCT06396364. Level of evidence I (RCT).
- Open Access
- 30 May 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (6) , 589
Robotic Total Knee Arthroplasty: An Update
Total knee arthroplasty (TKA) is a gold standard surgical procedure to improve pain and restore function in patients affected by moderate-to-severe severe gonarthrosis refractory to conservative treatments. Indeed, millions of these procedures are conducted yearly worldwide, with their number expected to increase in an ageing and more demanding population. Despite the progress that has been made in optimizing surgical techniques, prosthetic designs, and durability, up to 20% of patients are dissatisfied by the procedure or still report knee pain. From this perspective, the introduction of robotic TKA (R-TKA) in the late 1990s represented a valuable instrument in performing more accurate bone cuts and improving clinical outcomes. On the other hand, prolonged operative time, increased complications, and high costs of the devices slow down the diffusion of R-TKA. The advent of newer technological devices, including those using navigation systems, has made robotic surgery in the operatory room more common since the last decade. At present, many different robots are available, representing promising solutions to avoid persistent knee pain after TKA. We hereby describe their functionality, analyze potential benefits, and hint at future perspectives in this promising field.
- 30 May 2024
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 14 (6) , 589
Open AccessRobotic Total Knee Arthroplasty: An Update
Total knee arthroplasty (TKA) is a gold standard surgical procedure to improve pain and restore function in patients affected by moderate-to-severe severe gonarthrosis refractory to conservative treatments. Indeed, millions of these procedures are conducted yearly worldwide, with their number expected to increase in an ageing and more demanding population. Despite the progress that has been made in optimizing surgical techniques, prosthetic designs, and durability, up to 20% of patients are dissatisfied by the procedure or still report knee pain. From this perspective, the introduction of robotic TKA (R-TKA) in the late 1990s represented a valuable instrument in performing more accurate bone cuts and improving clinical outcomes. On the other hand, prolonged operative time, increased complications, and high costs of the devices slow down the diffusion of R-TKA. The advent of newer technological devices, including those using navigation systems, has made robotic surgery in the operatory room more common since the last decade. At present, many different robots are available, representing promising solutions to avoid persistent knee pain after TKA. We hereby describe their functionality, analyze potential benefits, and hint at future perspectives in this promising field.