Nuo Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nuo Zhang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Qin Wei
University of Jinan
5 shared publications Hongmin Ma
Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, University of Jinan, Jinan, 250022, China
3 shared publications- Yaoguang Wang
School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250353, China
3 shared publications Bin Du
Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
2 shared publicationsDawei Fan
Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
2 shared publicationsHuan Wang
Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, University of Jinan, Jinan, 250022, China
2 shared publications
Latest Publications
- Open Access
- 10 March 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 366
Ultrasensitive Photoelectrochemical Immunoassay Strategy Based on Bi2S3/Ag2S for the Detection of the Inflammation Marker Procalcitonin
As an inflammatory marker, procalcitonin (PCT) is more representative than other traditional inflammatory markers. In this work, a highly efficient photoelectrochemical (PEC) immunosensor was constructed based on the photoactive material Bi2S3/Ag2S to realize the sensitive detection of PCT. Bi2S3 was prepared by a hydrothermal method, and Ag2S quantum dots were deposited on the ITO/Bi2S3 surface via in situ reduction. Bi2S3 is a kind of admirable photoelectric semiconductor nanomaterial on account of its moderate bandgap width and low binding rate of photogenerated electron holes, which can effectively convert light energy into electrical energy. Therefore, based on the energy level matching principle of Bi2S3 and Ag2S, a labeled Bi2S3/Ag2S PEC immunosensor was constructed, and the sensitive detection of PCT was successfully established. The linear detection range of the PEC immunosensor was 0.50 pg∙mL−1 to 50 ng∙mL−1, and the minimum detection limit was 0.18 pg∙mL−1. Compared with the traditional PEC strategy, the proposed PEC immunosensor is simple, convenient, and has good anti-interference, sensitivity, and specificity, which could provide a meaningful theoretical basis and reference value for the clinical detection of PCT.
- 10 March 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 366
Open AccessUltrasensitive Photoelectrochemical Immunoassay Strategy Based on Bi2S3/Ag2S for the Detection of the Inflammation Marker Procalcitonin
As an inflammatory marker, procalcitonin (PCT) is more representative than other traditional inflammatory markers. In this work, a highly efficient photoelectrochemical (PEC) immunosensor was constructed based on the photoactive material Bi2S3/Ag2S to realize the sensitive detection of PCT. Bi2S3 was prepared by a hydrothermal method, and Ag2S quantum dots were deposited on the ITO/Bi2S3 surface via in situ reduction. Bi2S3 is a kind of admirable photoelectric semiconductor nanomaterial on account of its moderate bandgap width and low binding rate of photogenerated electron holes, which can effectively convert light energy into electrical energy. Therefore, based on the energy level matching principle of Bi2S3 and Ag2S, a labeled Bi2S3/Ag2S PEC immunosensor was constructed, and the sensitive detection of PCT was successfully established. The linear detection range of the PEC immunosensor was 0.50 pg∙mL−1 to 50 ng∙mL−1, and the minimum detection limit was 0.18 pg∙mL−1. Compared with the traditional PEC strategy, the proposed PEC immunosensor is simple, convenient, and has good anti-interference, sensitivity, and specificity, which could provide a meaningful theoretical basis and reference value for the clinical detection of PCT.
- 22 January 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 7 (7) , 1142-1148
An amplification label of core–shell CdSe@CdS QD sensitized GO for a signal-on photoelectrochemical immunosensor for amyloid β-protein
In this work, the heterostructures of Au nanoparticles loaded on 3D flower-like α-Fe2O3 (Au NPs/α-Fe2O3) as a platform and core–shell CdSe@CdS quantum dots sensitized graphene oxide (GO/CdSe@CdS QDs) as a signal amplification label were established in an ultrasensitive sandwich-type photoelectrochemical (PEC) immunosensor based on the “signal-on” type amplification method for detection of amyloid β-protein (Aβ). Specifically, the ultrahigh sensitivity of the proposed immunosensor came from two main properties. First, Au NPs/α-Fe2O3 could partially absorb visible-light, which dramatically promotes electron transfer because of the excellent conductivity of Au NPs, and effectively inhibits the electron–hole recombination, thanks to the effect of heterostructures. Second, the signal-on type is based on the signal amplification label of GO/CdSe@CdS QDs which on adequate absorption of visible-light can improve generation of photogenerated electron–hole pairs effectively. Under optimal conditions, the well-prepared PEC immunosensor exhibited a low detection limit of 0.02 pg mL−1 and a wide linear range from 0.06 pg mL−1 to 350 ng mL−1 for Aβ detection. Meanwhile, it also presented good reproducibility, specificity, and stability and might open a new promising pathway for detection of other important biomarkers.
- 22 January 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 7 (7) , 1142-1148
An amplification label of core–shell CdSe@CdS QD sensitized GO for a signal-on photoelectrochemical immunosensor for amyloid β-protein
In this work, the heterostructures of Au nanoparticles loaded on 3D flower-like α-Fe2O3 (Au NPs/α-Fe2O3) as a platform and core–shell CdSe@CdS quantum dots sensitized graphene oxide (GO/CdSe@CdS QDs) as a signal amplification label were established in an ultrasensitive sandwich-type photoelectrochemical (PEC) immunosensor based on the “signal-on” type amplification method for detection of amyloid β-protein (Aβ). Specifically, the ultrahigh sensitivity of the proposed immunosensor came from two main properties. First, Au NPs/α-Fe2O3 could partially absorb visible-light, which dramatically promotes electron transfer because of the excellent conductivity of Au NPs, and effectively inhibits the electron–hole recombination, thanks to the effect of heterostructures. Second, the signal-on type is based on the signal amplification label of GO/CdSe@CdS QDs which on adequate absorption of visible-light can improve generation of photogenerated electron–hole pairs effectively. Under optimal conditions, the well-prepared PEC immunosensor exhibited a low detection limit of 0.02 pg mL−1 and a wide linear range from 0.06 pg mL−1 to 350 ng mL−1 for Aβ detection. Meanwhile, it also presented good reproducibility, specificity, and stability and might open a new promising pathway for detection of other important biomarkers.
- 1 November 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 120, 1-7
Ultrasensitive photoelectrochemical immunosensor for the detection of amyloid β-protein based on SnO2/SnS2/Ag2S nanocomposites
- 1 November 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 120, 1-7
Ultrasensitive photoelectrochemical immunosensor for the detection of amyloid β-protein based on SnO2/SnS2/Ag2S nanocomposites