Axel Joachim Krafft
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Axel Joachim Krafft has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Horst Urbach
Department of Neuroradiology, Medical Center - University of Freiburg, Freiburg, Germany
2 shared publications - Michael Bock
Division of Medical Physics, Department of Diagnostic and Interventional Radiology Medical Center – University of Freiburg, Faculty of Medicine – University of Freiburg Freiburg Germany
2 shared publications - Aaryani Tipirneni-Sajja
Department of Biomedical Engineering, The University of Memphis, Memphis, USA
1 shared publication Andreas Harloff
1 shared publication- Andreas Harloff
Department of Neurology and Neurophysiology, University Medical Center Freiburg, Faculty of Medicine University of Freiburg Germany
1 shared publication - Andreas Reichert
Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany
1 shared publication
Latest Publications
- 15 November 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (5) , 879-886
High Wall Shear Stress Is Related to Complicated American Heart Association Lesion Type VI Plaques in Mild-to-Moderate ICA Stenosis: A 3D Cardiovascular MRI Study
BACKGROUND AND PURPOSE: Complicated American Heart Association (AHA) lesion type VI plaques (cCAPs), characterized by the presence of intraplaque hemorrhage, surface defect or thrombus, are strongly associated with ischemic stroke and stroke recurrence. Hemodynamics seem to play a relevant role for their development. Thus, we investigated the association of 4D flow-MRI derived local wall shear stress (WSS) and oscillatory shear stress (OSI) with the presence of cCAPs in patients with mild to moderate internal carotid artery (ICA) stenosis. MATERIALS AND METHODS: From a prospective and consecutive cross-sectional study with 121 patients with high cardiovascular risk, 39 patients (49 carotid arteries) demonstrated a 10-50% ICA-stenosis and were included in this analysis. Plaque composition was determined according to the modified AHA classification of lesions by high-resolution multi-contrast 3T-MRI. We determined WSS (minimum, mean and maximum) and OSI in vivo by 4D flow-MRI at different locations within the stenosis (upstream, stenosis center and downstream). We studied the association of each hemodynamic parameter with the presence cCAPs by logistic regression analysis adjusted for age, sex and plaque thickness. RESULTS: 11 (22.4%) of the 49 ICA-stenosis in our cohort showed cCAP. WSS and OSI at the beginning of the stenosis did not differ between complicated and stable plaques. By contrast, WSS was significantly higher in the stenosis center and poststenotic region in cCAPs. OSI was significantly higher in the stenosis center of stable plaques. Logistic regression analysis revealed a significant association for WSSmean (OR per SD increase 1.97, 95%-CI 1.14-3.39, p=0.015) and for WSSmax (OR per SD increase 1.84; 95%-CI 1.10-3.08; p=0.020), but not for WSSmin and OSI with the presence of cCAPs. CONCLUSIONS: Higher wall shear stress in ICA stenosis was significantly associated with the presence of cCAPs underlining the potential role of hemodynamics in their development. ABBREVIATIONS: cCAP, complicated carotid artery plaque; WSS, wall shear stress; OSI, oscillatory shear index.
- 15 November 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (5) , 879-886
High Wall Shear Stress Is Related to Complicated American Heart Association Lesion Type VI Plaques in Mild-to-Moderate ICA Stenosis: A 3D Cardiovascular MRI Study
BACKGROUND AND PURPOSE: Complicated American Heart Association (AHA) lesion type VI plaques (cCAPs), characterized by the presence of intraplaque hemorrhage, surface defect or thrombus, are strongly associated with ischemic stroke and stroke recurrence. Hemodynamics seem to play a relevant role for their development. Thus, we investigated the association of 4D flow-MRI derived local wall shear stress (WSS) and oscillatory shear stress (OSI) with the presence of cCAPs in patients with mild to moderate internal carotid artery (ICA) stenosis. MATERIALS AND METHODS: From a prospective and consecutive cross-sectional study with 121 patients with high cardiovascular risk, 39 patients (49 carotid arteries) demonstrated a 10-50% ICA-stenosis and were included in this analysis. Plaque composition was determined according to the modified AHA classification of lesions by high-resolution multi-contrast 3T-MRI. We determined WSS (minimum, mean and maximum) and OSI in vivo by 4D flow-MRI at different locations within the stenosis (upstream, stenosis center and downstream). We studied the association of each hemodynamic parameter with the presence cCAPs by logistic regression analysis adjusted for age, sex and plaque thickness. RESULTS: 11 (22.4%) of the 49 ICA-stenosis in our cohort showed cCAP. WSS and OSI at the beginning of the stenosis did not differ between complicated and stable plaques. By contrast, WSS was significantly higher in the stenosis center and poststenotic region in cCAPs. OSI was significantly higher in the stenosis center of stable plaques. Logistic regression analysis revealed a significant association for WSSmean (OR per SD increase 1.97, 95%-CI 1.14-3.39, p=0.015) and for WSSmax (OR per SD increase 1.84; 95%-CI 1.10-3.08; p=0.020), but not for WSSmin and OSI with the presence of cCAPs. CONCLUSIONS: Higher wall shear stress in ICA stenosis was significantly associated with the presence of cCAPs underlining the potential role of hemodynamics in their development. ABBREVIATIONS: cCAP, complicated carotid artery plaque; WSS, wall shear stress; OSI, oscillatory shear index.
- Open Access
- 26 January 2024
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 34 (2) , 391-401
Interrelation Between Cerebrospinal Fluid Pressure, Intracranial Morphology and Venous Hemodynamics Studied by 4D Flow MRI
Purpose: To quantify the effects of CSF pressure alterations on intracranial venous morphology and hemodynamics in idiopathic intracranial hypertension (IIH) and spontaneous intracranial hypotension (SIH) and assess reversibility when the underlying cause is resolved. Methods: We prospectively examined venous volume, intracranial venous blood flow and velocity, including optic nerve sheath diameter (ONSD) as a noninvasive surrogate of CSF pressure changes in 11 patients with IIH, 11 age-matched and sex-matched healthy controls and 9 SIH patients, before and after neurosurgical closure of spinal dural leaks. We applied multiparametric MRI including 4D flow MRI, time-of-flight (TOF) and T2-weighted half-Fourier acquisition single-shot turbo-spin echo (HASTE). Results: Sinus volume overlapped between groups at baseline but decreased after treatment of intracranial hypotension (p = 0.067) along with a significant increase of ONSD (p = 0.003). Blood flow in the middle and dorsal superior sagittal sinus was remarkably lower in patients with higher CSF pressure (i.e., IIH versus controls and SIH after CSF leak closure) but blood flow velocity was comparable cross-sectionally between groups and longitudinally in SIH. Conclusion: We were able to demonstrate the interaction of CSF pressure, venous volumetry, venous hemodynamics and ONSD using multiparametric brain MRI. Closure of CSF leaks in SIH patients resulted in symptoms suggestive of increased intracranial pressure and caused a subsequent decrease of intracranial venous volume and of blood flow within the superior sagittal sinus while ONSD increased. In contrast, blood flow parameters from 4D flow MRI did not discriminate IIH, SIH and controls as hemodynamics at baseline overlapped at most vessel cross-sections.
- 26 January 2024
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 34 (2) , 391-401
Open AccessInterrelation Between Cerebrospinal Fluid Pressure, Intracranial Morphology and Venous Hemodynamics Studied by 4D Flow MRI
Purpose: To quantify the effects of CSF pressure alterations on intracranial venous morphology and hemodynamics in idiopathic intracranial hypertension (IIH) and spontaneous intracranial hypotension (SIH) and assess reversibility when the underlying cause is resolved. Methods: We prospectively examined venous volume, intracranial venous blood flow and velocity, including optic nerve sheath diameter (ONSD) as a noninvasive surrogate of CSF pressure changes in 11 patients with IIH, 11 age-matched and sex-matched healthy controls and 9 SIH patients, before and after neurosurgical closure of spinal dural leaks. We applied multiparametric MRI including 4D flow MRI, time-of-flight (TOF) and T2-weighted half-Fourier acquisition single-shot turbo-spin echo (HASTE). Results: Sinus volume overlapped between groups at baseline but decreased after treatment of intracranial hypotension (p = 0.067) along with a significant increase of ONSD (p = 0.003). Blood flow in the middle and dorsal superior sagittal sinus was remarkably lower in patients with higher CSF pressure (i.e., IIH versus controls and SIH after CSF leak closure) but blood flow velocity was comparable cross-sectionally between groups and longitudinally in SIH. Conclusion: We were able to demonstrate the interaction of CSF pressure, venous volumetry, venous hemodynamics and ONSD using multiparametric brain MRI. Closure of CSF leaks in SIH patients resulted in symptoms suggestive of increased intracranial pressure and caused a subsequent decrease of intracranial venous volume and of blood flow within the superior sagittal sinus while ONSD increased. In contrast, blood flow parameters from 4D flow MRI did not discriminate IIH, SIH and controls as hemodynamics at baseline overlapped at most vessel cross-sections.
- Open Access
- 19 August 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (11) , e4394
Analysis of accelerated 4D flow MRI in the murine aorta by radial acquisition and compressed sensing reconstruction
Preclinical 4D flow MRI remains challenging and is restricted for parallel imaging acceleration due to the limited number of available receive channels. A radial acquisition with combined parallel imaging and temporal compressed sensing reconstruction was implemented to achieve accelerated preclinical 4D flow MRI. In order to increase the accuracy of the measured velocities, a quantitative evaluation of different temporal regularization weights for the compressed sensing reconstruction based on velocity instead of magnitude data is performed. A 3D radial retrospectively triggered phase contrast sequence with a combined parallel imaging and compressed sensing reconstruction with temporal regularization was developed. It was validated in a phantom and in vivo (C57BL/6 J mice), against an established fully sampled Cartesian sequence. Different undersampling factors (USFs [12, 15, 20, 30, 60]) were evaluated, and the effect of undersampling was analyzed in detail for magnitude and velocity data. Temporal regularization weights λ were evaluated for different USFs. Acceleration factors of up to 20 compared with full Nyquist sampling were achieved. The peak flow differences compared with the Cartesian measurement were the following: USF 12, 3.38%; USF 15, 4.68%; USF 20, 0.95%. The combination of 3D radial center‐out trajectories and compressed sensing reconstruction is robust against motion and flow artifacts and can significantly reduce measurement time to 30 min at a resolution of 180 μm3. Concisely, radial acquisition with combined compressed sensing and parallel imaging proved to be an excellent method for analyzing complex flow patterns in mice.
- 19 August 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (11) , e4394
Open AccessAnalysis of accelerated 4D flow MRI in the murine aorta by radial acquisition and compressed sensing reconstruction
Preclinical 4D flow MRI remains challenging and is restricted for parallel imaging acceleration due to the limited number of available receive channels. A radial acquisition with combined parallel imaging and temporal compressed sensing reconstruction was implemented to achieve accelerated preclinical 4D flow MRI. In order to increase the accuracy of the measured velocities, a quantitative evaluation of different temporal regularization weights for the compressed sensing reconstruction based on velocity instead of magnitude data is performed. A 3D radial retrospectively triggered phase contrast sequence with a combined parallel imaging and compressed sensing reconstruction with temporal regularization was developed. It was validated in a phantom and in vivo (C57BL/6 J mice), against an established fully sampled Cartesian sequence. Different undersampling factors (USFs [12, 15, 20, 30, 60]) were evaluated, and the effect of undersampling was analyzed in detail for magnitude and velocity data. Temporal regularization weights λ were evaluated for different USFs. Acceleration factors of up to 20 compared with full Nyquist sampling were achieved. The peak flow differences compared with the Cartesian measurement were the following: USF 12, 3.38%; USF 15, 4.68%; USF 20, 0.95%. The combination of 3D radial center‐out trajectories and compressed sensing reconstruction is robust against motion and flow artifacts and can significantly reduce measurement time to 30 min at a resolution of 180 μm3. Concisely, radial acquisition with combined compressed sensing and parallel imaging proved to be an excellent method for analyzing complex flow patterns in mice.
- 18 December 2019
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 31 (1) , 207-216
High-resolution Compressed-sensing T1 Black-blood MRI
In vasculopathies of the central nervous system, reliable and timely diagnosis is important against the background of significant morbidity and sequelae in cases of incorrect diagnosis or delayed treatment. Magnetic resonance imaging (MRI) plays a major role in the detection and monitoring of intracranial and extracranial vascular pathologies of different etiologies, in particular for evaluation of the vessel wall in addition to luminal information, thus allowing differentiation between various vasculopathies. Compressed-sensing black-blood MRI combines high image quality with relatively short acquisition time and offers promising potential in the context of neurovascular vessel wall imaging in clinical routine. This case review gives an overview of its application in the diagnosis of various intracranial and extracranial entities.
- 18 December 2019
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 31 (1) , 207-216
High-resolution Compressed-sensing T1 Black-blood MRI
In vasculopathies of the central nervous system, reliable and timely diagnosis is important against the background of significant morbidity and sequelae in cases of incorrect diagnosis or delayed treatment. Magnetic resonance imaging (MRI) plays a major role in the detection and monitoring of intracranial and extracranial vascular pathologies of different etiologies, in particular for evaluation of the vessel wall in addition to luminal information, thus allowing differentiation between various vasculopathies. Compressed-sensing black-blood MRI combines high image quality with relatively short acquisition time and offers promising potential in the context of neurovascular vessel wall imaging in clinical routine. This case review gives an overview of its application in the diagnosis of various intracranial and extracranial entities.
- 6 September 2018
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 31 (6) , 781-788
Simultaneous slice excitation for accelerated passive marker tracking via phase-only cross correlation (POCC) in MR-guided needle interventions
Objective To accelerate a passive tracking sequence based on phase-only cross correlation (POCC) using simultaneous slice excitation. Methods For magnetic resonance (MR)-guided biopsy procedures, passive markers have been proposed that can be automatically localized online using a POCC-based tracking sequence. To accelerate the sequence, a phase-offset multiplanar (POMP) excitation technique was implemented to acquire tracking images. In a phantom experiment, the POMP–POCC sequence was tested and compared with the sequential non-accelerated version in terms of duration and accuracy. Further, technical feasibility of the POMP–POCC sequence was tested in a patient undergoing a prostate biopsy. Results The temporal resolution of the POMP–POCC tracking sequence is accelerated by 33% compared with the sequential approach. In phantom experiments, the POMP–POCC and sequential sequences yielded the same targeting accuracy of 1.6 ± 0.7 mm. Technical proof of concept of the new sequence could be demonstrated in a successful in vivo prostate biopsy. Conclusion POMP–POCC tracking can substantially reduce the duration of localization of passive markers in MR-guided needle interventions without compromising targeting accuracy.
- 6 September 2018
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 31 (6) , 781-788
Simultaneous slice excitation for accelerated passive marker tracking via phase-only cross correlation (POCC) in MR-guided needle interventions
Objective To accelerate a passive tracking sequence based on phase-only cross correlation (POCC) using simultaneous slice excitation. Methods For magnetic resonance (MR)-guided biopsy procedures, passive markers have been proposed that can be automatically localized online using a POCC-based tracking sequence. To accelerate the sequence, a phase-offset multiplanar (POMP) excitation technique was implemented to acquire tracking images. In a phantom experiment, the POMP–POCC sequence was tested and compared with the sequential non-accelerated version in terms of duration and accuracy. Further, technical feasibility of the POMP–POCC sequence was tested in a patient undergoing a prostate biopsy. Results The temporal resolution of the POMP–POCC tracking sequence is accelerated by 33% compared with the sequential approach. In phantom experiments, the POMP–POCC and sequential sequences yielded the same targeting accuracy of 1.6 ± 0.7 mm. Technical proof of concept of the new sequence could be demonstrated in a successful in vivo prostate biopsy. Conclusion POMP–POCC tracking can substantially reduce the duration of localization of passive markers in MR-guided needle interventions without compromising targeting accuracy.
- Open Access
- 1 July 2017
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 209 (1) , 187-194
Radial Ultrashort TE Imaging Removes the Need for Breath-Holding in Hepatic Iron Overload Quantification by R2* MRI
OBJECTIVE. The objective of this study is to evaluate radial free-breathing (FB) multiecho ultrashort TE (UTE) imaging as an alternative to Cartesian FB multiecho gradient-recalled echo (GRE) imagi...
- 1 July 2017
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 209 (1) , 187-194
Open AccessRadial Ultrashort TE Imaging Removes the Need for Breath-Holding in Hepatic Iron Overload Quantification by R2* MRI
OBJECTIVE. The objective of this study is to evaluate radial free-breathing (FB) multiecho ultrashort TE (UTE) imaging as an alternative to Cartesian FB multiecho gradient-recalled echo (GRE) imagi...
- Open Access
- 1 November 2013
- Published by Elsevier in Physica Medica
- Vol. 29 (6) , 607-614
Passive marker tracking via phase-only cross correlation (POCC) for MR-guided needle interventions: Initial in vivo experience
- 1 November 2013
- Published by Elsevier in Physica Medica
- Vol. 29 (6) , 607-614
Open AccessPassive marker tracking via phase-only cross correlation (POCC) for MR-guided needle interventions: Initial in vivo experience