Cory Czarnik
Research Subjects
Cory Czarnik has a total of 220 co-authors. Here are the top co-authors by number of shared publications:
Anahita Pakzad
Gatan Inc
2 shared publications- Cyntia Taveneau
Monash University
2 shared publications - David M. Thal
Drug Discovery Biology, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Australia
2 shared publications - Gavin John Knott
Monash University
2 shared publications - Georg Ramm
Ramaciotti Centre for Cryo-Electron Microscopy, Monash University, 15 Innovation Walk, Melbourne, 3800, VIC, Australia
2 shared publications - Hariprasad Venugopal
Ramaciotti Centre for Cryo-Electron Microscopy, Monash University, Clayton, Australia
2 shared publications
Latest Publications
- Open Access
- 3 January 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (1) , eadr0438
High-resolution cryo-EM using a common LaB 6 120-keV electron microscope equipped with a sub–200-keV direct electron detector
High-resolution cryo–electron microscopy (cryo-EM) requires costly 200- to 300-keV cryo–transmission electron microscopes (cryo-TEMs) with field emission gun (FEG) sources, stable columns, constant-powered lenses, autoloader, and direct electron detectors (DED). Recent advances in 100-keV imaging with the emergence of sub–200-keV optimized DED technology promises the development of more affordable cryo-TEMs. So far, 100-keV imaging has required microscopes with FEG sources. We here explored whether a standard 120-keV TEMs with thermionic lanthanum hexaboride (LaB 6 ) source can be upgraded with a sub–200-keV DED for high-resolution cryo-EM. Using this imaging configuration, we successfully obtained a 2.65 Å reconstruction for apoferritin, 4.33 Å for 64-kDa hemoglobin, and 4.4 Å for an asymmetric 153kDa membrane protein GPCR. All results were achieved using standard automated data collection with SerialEM, demonstrating the feasibility to collect large cryo-EM datasets with a side-entry cryo-holder. These results showcase a widely accessible solution to obtaining interpretable cryo-EM structures at low cost and contribute to the “democratization” of cryo-EM.
- 3 January 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (1) , eadr0438
Open AccessHigh-resolution cryo-EM using a common LaB 6 120-keV electron microscope equipped with a sub–200-keV direct electron detector
High-resolution cryo–electron microscopy (cryo-EM) requires costly 200- to 300-keV cryo–transmission electron microscopes (cryo-TEMs) with field emission gun (FEG) sources, stable columns, constant-powered lenses, autoloader, and direct electron detectors (DED). Recent advances in 100-keV imaging with the emergence of sub–200-keV optimized DED technology promises the development of more affordable cryo-TEMs. So far, 100-keV imaging has required microscopes with FEG sources. We here explored whether a standard 120-keV TEMs with thermionic lanthanum hexaboride (LaB 6 ) source can be upgraded with a sub–200-keV DED for high-resolution cryo-EM. Using this imaging configuration, we successfully obtained a 2.65 Å reconstruction for apoferritin, 4.33 Å for 64-kDa hemoglobin, and 4.4 Å for an asymmetric 153kDa membrane protein GPCR. All results were achieved using standard automated data collection with SerialEM, demonstrating the feasibility to collect large cryo-EM datasets with a side-entry cryo-holder. These results showcase a widely accessible solution to obtaining interpretable cryo-EM structures at low cost and contribute to the “democratization” of cryo-EM.
- Open Access
- 28 June 2024
- Published by Elsevier in Journal of Structural Biology
- Vol. 216 (3) , 108108
High-resolution single-particle imaging at 100–200 keV with the Gatan Alpine direct electron detector
- 28 June 2024
- Published by Elsevier in Journal of Structural Biology
- Vol. 216 (3) , 108108
Open AccessHigh-resolution single-particle imaging at 100–200 keV with the Gatan Alpine direct electron detector
- Open Access
Obtaining high-resolution cryo-EM structures using a common LaB6, 120-keV electron microscope equipped with a sub 200-keV optimised direct electron detector
Cryo-electron microscopy (Cryo-EM) single particle analysis (SPA) has become a major structural biology technique in recent years. High-resolution cryo-EM typically requires higher voltage cryo-TEMs with coherent FEG sources, stable columns, autoloader systems and direct electron detectors. These setups are specialised for Cryo-EM work and are expensive to establish and maintain. More recently the concept of using 100-keV cryo-TEMs has been introduced as a way to make cryo-EM more affordable and hence accessible to a larger group of researchers. So far, the implementation of these 100-keV cryo-TEMs have relied on specialised microscopes with FEG sources as well as more stable optics than usually present on the common 120-keV TEMs. We here explored whether a standard 120-keV TEM, commonly available at many laboratories worldwide, can be upgraded with a direct electron detector and its suitability for high-resolution cryo-EM using a standard side entry cryo-holder. Using this imaging configuration, we were successful in achieving a 2.65Å reconstruction for standard apoferritin. We were also able to resolve a more challenging small 64kDa protein haemoglobin to 4.33Å. Furthermore, we were able to solve an asymmetric 153 kDa membrane protein GPCR (M4 muscarinic acid receptor) to a resolution of 4.4Å. Importantly, all these results were achieved using a standard automated data collection routine implemented through SerialEM, making it feasible to collect large cryo-EM data sets with a side entry cryo-holder. These results showcase a potentially widely accessible solution to obtaining interpretable cryo-EM structures. Furthermore, we envisage that this imaging configuration gives an option for many EM facilities and laboratories to set up a high-quality cryo-EM SPA sample screening capability without the need to procure costly specialised Cryo-TEMs. This could help to considerably lower the economic entry barrier for cryo-EM SPA and contribute to the “democratisation” of cryo-EM.
Open AccessObtaining high-resolution cryo-EM structures using a common LaB6, 120-keV electron microscope equipped with a sub 200-keV optimised direct electron detector
Cryo-electron microscopy (Cryo-EM) single particle analysis (SPA) has become a major structural biology technique in recent years. High-resolution cryo-EM typically requires higher voltage cryo-TEMs with coherent FEG sources, stable columns, autoloader systems and direct electron detectors. These setups are specialised for Cryo-EM work and are expensive to establish and maintain. More recently the concept of using 100-keV cryo-TEMs has been introduced as a way to make cryo-EM more affordable and hence accessible to a larger group of researchers. So far, the implementation of these 100-keV cryo-TEMs have relied on specialised microscopes with FEG sources as well as more stable optics than usually present on the common 120-keV TEMs. We here explored whether a standard 120-keV TEM, commonly available at many laboratories worldwide, can be upgraded with a direct electron detector and its suitability for high-resolution cryo-EM using a standard side entry cryo-holder. Using this imaging configuration, we were successful in achieving a 2.65Å reconstruction for standard apoferritin. We were also able to resolve a more challenging small 64kDa protein haemoglobin to 4.33Å. Furthermore, we were able to solve an asymmetric 153 kDa membrane protein GPCR (M4 muscarinic acid receptor) to a resolution of 4.4Å. Importantly, all these results were achieved using a standard automated data collection routine implemented through SerialEM, making it feasible to collect large cryo-EM data sets with a side entry cryo-holder. These results showcase a potentially widely accessible solution to obtaining interpretable cryo-EM structures. Furthermore, we envisage that this imaging configuration gives an option for many EM facilities and laboratories to set up a high-quality cryo-EM SPA sample screening capability without the need to procure costly specialised Cryo-TEMs. This could help to considerably lower the economic entry barrier for cryo-EM SPA and contribute to the “democratisation” of cryo-EM.
- Open Access
- 30 July 2021
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 27 (S1) , 1352-1354
Using py4DSTEM in GMS: Hybrid Open-Source, Commercial-Freeware Methods for Analyzing 4D STEM Datasets
- 30 July 2021
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 27 (S1) , 1352-1354
Open AccessUsing py4DSTEM in GMS: Hybrid Open-Source, Commercial-Freeware Methods for Analyzing 4D STEM Datasets
- Open Access
- 1 February 2016
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 22 (S3) , f1-f90
MAM volume 22 issue s3 Cover and Front matter
- 1 February 2016
- Published by Cambridge University Press (CUP) in Microscopy and Microanalysis
- Vol. 22 (S3) , f1-f90
Open AccessMAM volume 22 issue s3 Cover and Front matter