Dallas K. Tada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dallas K. Tada has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ashley Banola
The University of California, Los Angeles (UCLA), David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, California, United States
2 shared publications - Fereidoun Abtin
David Geffen School of Medicine at UCLA
2 shared publications - Grace Hyun J. Kim
University of California Los Angeles
2 shared publications - Jonathan Gerald Goldin
The University of California, Los Angeles (UCLA), David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, California, United States
2 shared publications - Kalyani Vyapari
The University of California, Los Angeles (UCLA), David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, California, United States
2 shared publications - Matthew S. Brown
The University of California, Los Angeles (UCLA), David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, California, United States
2 shared publications
Latest Publications
- 1 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (02) , 1-14
Using a fully automated, quantitative fissure integrity score extracted from chest CT scans of emphysema patients to predict endobronchial valve response
PurposeWe aim to develop and validate a prediction model using a previously developed fully automated quantitative fissure integrity score (FIS) extracted from pre-treatment CT images to identify suitable candidates for endobronchial valve (EBV) treatment.ApproachWe retrospectively collected 96 anonymized pre- and post-treatment chest computed tomography (CT) exams from patients with moderate to severe emphysema and who underwent EBV treatment. We used a previously developed fully automated, deep learning–based approach to quantitatively assess the completeness of each fissure by obtaining the FIS for each fissure from each patient’s pre-treatment CT exam. The response to EBV treatment was recorded as the amount of targeted lobe volume reduction (TLVR) compared with target lobe volume prior to treatment as assessed on the pre- and post-treatment CT scans. EBV placement was considered successful with a TLVR of ≥350 cc. The dataset was split into a training set (N=58) and a test set (N=38) to train and validate a logistic regression model using fivefold cross-validation; the extracted FIS of each patient’s targeted treatment lobe was the primary CT predictor. Using the training set, a receiver operating characteristic (ROC) curve analysis and predictive values were quantified over a range of FIS thresholds to determine an optimal cutoff value that would distinguish complete and incomplete fissures, which was used to evaluate predictive values of the test set cases.ResultsROC analysis of the training set provided an AUC of 0.83, and the determined FIS threshold was 89.5%. Using this threshold on the test set achieved an accuracy of 81.6%, specificity (Sp) of 90.9%, sensitivity (Sn) of 77.8%, positive predictive value (PPV) of 62.5%, and negative predictive value of 95.5%.ConclusionsA model using the quantified FIS shows potential as a predictive biomarker for whether a targeted lobe will achieve successful volume reduction from EBV treatment.
- 1 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (02) , 1-14
Using a fully automated, quantitative fissure integrity score extracted from chest CT scans of emphysema patients to predict endobronchial valve response
PurposeWe aim to develop and validate a prediction model using a previously developed fully automated quantitative fissure integrity score (FIS) extracted from pre-treatment CT images to identify suitable candidates for endobronchial valve (EBV) treatment.ApproachWe retrospectively collected 96 anonymized pre- and post-treatment chest computed tomography (CT) exams from patients with moderate to severe emphysema and who underwent EBV treatment. We used a previously developed fully automated, deep learning–based approach to quantitatively assess the completeness of each fissure by obtaining the FIS for each fissure from each patient’s pre-treatment CT exam. The response to EBV treatment was recorded as the amount of targeted lobe volume reduction (TLVR) compared with target lobe volume prior to treatment as assessed on the pre- and post-treatment CT scans. EBV placement was considered successful with a TLVR of ≥350 cc. The dataset was split into a training set (N=58) and a test set (N=38) to train and validate a logistic regression model using fivefold cross-validation; the extracted FIS of each patient’s targeted treatment lobe was the primary CT predictor. Using the training set, a receiver operating characteristic (ROC) curve analysis and predictive values were quantified over a range of FIS thresholds to determine an optimal cutoff value that would distinguish complete and incomplete fissures, which was used to evaluate predictive values of the test set cases.ResultsROC analysis of the training set provided an AUC of 0.83, and the determined FIS threshold was 89.5%. Using this threshold on the test set achieved an accuracy of 81.6%, specificity (Sp) of 90.9%, sensitivity (Sn) of 77.8%, positive predictive value (PPV) of 62.5%, and negative predictive value of 95.5%.ConclusionsA model using the quantified FIS shows potential as a predictive biomarker for whether a targeted lobe will achieve successful volume reduction from EBV treatment.
- 1 May 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (03) , 1-19
Quantifying lung fissure integrity using a three-dimensional patch-based convolutional neural network on CT images for emphysema treatment planning
PurposeEvaluation of lung fissure integrity is required to determine whether emphysema patients have complete fissures and are candidates for endobronchial valve (EBV) therapy. We propose a deep learning (DL) approach to segment fissures using a three-dimensional patch-based convolutional neural network (CNN) and quantitatively assess fissure integrity on CT to evaluate it in subjects with severe emphysema.ApproachFrom an anonymized image database of patients with severe emphysema, 129 CT scans were used. Lung lobe segmentations were performed to identify lobar regions, and the boundaries among these regions were used to construct approximate interlobar regions of interest (ROIs). The interlobar ROIs were annotated by expert image analysts to identify voxels where the fissure was present and create a reference ROI that excluded non-fissure voxels (where the fissure is incomplete). A CNN configured by nnU-Net was trained using 86 CT scans and their corresponding reference ROIs to segment the ROIs of left oblique fissure (LOF), right oblique fissure (ROF), and right horizontal fissure (RHF). For an independent test set of 43 cases, fissure integrity was quantified by mapping the segmented fissure ROI along the interlobar ROI. A fissure integrity score (FIS) was then calculated as the percentage of labeled fissure voxels divided by total voxels in the interlobar ROI. Predicted FIS (p-FIS) was quantified from the CNN output, and statistical analyses were performed comparing p-FIS and reference FIS (r-FIS).ResultsThe absolute percent error mean (±SD) between r-FIS and p-FIS for the test set was 4.0% (±4.1%), 6.0% (±9.3%), and 12.2% (±12.5%) for the LOF, ROF, and RHF, respectively.ConclusionsA DL approach was developed to segment lung fissures on CT images and accurately quantify FIS. It has potential to assist in the identification of emphysema patients who would benefit from EBV treatment.
- 1 May 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (03) , 1-19
Quantifying lung fissure integrity using a three-dimensional patch-based convolutional neural network on CT images for emphysema treatment planning
PurposeEvaluation of lung fissure integrity is required to determine whether emphysema patients have complete fissures and are candidates for endobronchial valve (EBV) therapy. We propose a deep learning (DL) approach to segment fissures using a three-dimensional patch-based convolutional neural network (CNN) and quantitatively assess fissure integrity on CT to evaluate it in subjects with severe emphysema.ApproachFrom an anonymized image database of patients with severe emphysema, 129 CT scans were used. Lung lobe segmentations were performed to identify lobar regions, and the boundaries among these regions were used to construct approximate interlobar regions of interest (ROIs). The interlobar ROIs were annotated by expert image analysts to identify voxels where the fissure was present and create a reference ROI that excluded non-fissure voxels (where the fissure is incomplete). A CNN configured by nnU-Net was trained using 86 CT scans and their corresponding reference ROIs to segment the ROIs of left oblique fissure (LOF), right oblique fissure (ROF), and right horizontal fissure (RHF). For an independent test set of 43 cases, fissure integrity was quantified by mapping the segmented fissure ROI along the interlobar ROI. A fissure integrity score (FIS) was then calculated as the percentage of labeled fissure voxels divided by total voxels in the interlobar ROI. Predicted FIS (p-FIS) was quantified from the CNN output, and statistical analyses were performed comparing p-FIS and reference FIS (r-FIS).ResultsThe absolute percent error mean (±SD) between r-FIS and p-FIS for the test set was 4.0% (±4.1%), 6.0% (±9.3%), and 12.2% (±12.5%) for the LOF, ROF, and RHF, respectively.ConclusionsA DL approach was developed to segment lung fissures on CT images and accurately quantify FIS. It has potential to assist in the identification of emphysema patients who would benefit from EBV treatment.