Ivan Cherh Chiet Low
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ivan Cherh Chiet Low has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Aziz BIN Abdul Karim
Department of Emergency Medicine, Singapore General Hospital, Singapore
1 shared publication Charis Yi Ning Chiang
Department of Biomedical Engineering, National University of Singapore, Singapore, Singapore
1 shared publication- Jason Kai Wei Lee
National University of Singapore
1 shared publication Jieming Pan
Department of Electrical and Computer Engineering, National University of Singapore, Singapore, Singapore
1 shared publication- Louisa Si Xian Lim
Department of Physiology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
1 shared publication - R. Ponampalam
Department of Emergency Medicine, Singapore General Hospital, Singapore
1 shared publication
Latest Publications
- Open Access
- 30 May 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
External auricle temperature enhances ear-based wearable accuracy during physiological strain monitoring in the heat
Body core temperature (Tc) monitoring is crucial for minimizing heat injury risk. However, validated strategies are invasive and expensive. Although promising, aural canal temperature (Tac) is susceptible to environmental influences. This study investigated whether incorporation of external auricle temperature (Tea) into an ear-based Tc algorithm enhances its accuracy during multiple heat stress conditions. Twenty males (mean ± SD; age = 25 ± 3 years, BMI = 21.7 ± 1.8, body fat = 12 ± 3%, maximal aerobic capacity (VO2max) = 64 ± 7 ml/kg/min) donned an ear-based wearable and performed a passive heating (PAH), running (RUN) and brisk walking trial (WALK). PAH comprised of immersion in hot water (42.0 ± 0.3 °C). RUN (70 ± 3%VO2max) and WALK (50 ± 10%VO2max) were conducted in an environmental chamber (Tdb = 30.0 ± 0.2 °C, RH = 71 ± 2%). Several Tc models, developed using Tac, Tea and heart rate, were validated against gastrointestinal temperature. Inclusion of Tea as a model input improved the accuracy of the ear-based Tc algorithm. Our best performing model (Trf3) displayed good group prediction errors (mean bias error = − 0.02 ± 0.26 °C) but exhibited individual prediction errors (percentage target attainment ± 0.40 °C = 88%) that marginally exceeded our validity criterion. Therefore, Trf3 demonstrates potential utility for group-based Tc monitoring, with additional refinement needed to extend its applicability to personalized heat strain monitoring.
- 30 May 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Open AccessExternal auricle temperature enhances ear-based wearable accuracy during physiological strain monitoring in the heat
Body core temperature (Tc) monitoring is crucial for minimizing heat injury risk. However, validated strategies are invasive and expensive. Although promising, aural canal temperature (Tac) is susceptible to environmental influences. This study investigated whether incorporation of external auricle temperature (Tea) into an ear-based Tc algorithm enhances its accuracy during multiple heat stress conditions. Twenty males (mean ± SD; age = 25 ± 3 years, BMI = 21.7 ± 1.8, body fat = 12 ± 3%, maximal aerobic capacity (VO2max) = 64 ± 7 ml/kg/min) donned an ear-based wearable and performed a passive heating (PAH), running (RUN) and brisk walking trial (WALK). PAH comprised of immersion in hot water (42.0 ± 0.3 °C). RUN (70 ± 3%VO2max) and WALK (50 ± 10%VO2max) were conducted in an environmental chamber (Tdb = 30.0 ± 0.2 °C, RH = 71 ± 2%). Several Tc models, developed using Tac, Tea and heart rate, were validated against gastrointestinal temperature. Inclusion of Tea as a model input improved the accuracy of the ear-based Tc algorithm. Our best performing model (Trf3) displayed good group prediction errors (mean bias error = − 0.02 ± 0.26 °C) but exhibited individual prediction errors (percentage target attainment ± 0.40 °C = 88%) that marginally exceeded our validity criterion. Therefore, Trf3 demonstrates potential utility for group-based Tc monitoring, with additional refinement needed to extend its applicability to personalized heat strain monitoring.
- Open Access
- 15 May 2024
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 56 (10) , 2016-2025
Effects of Heat Exposure and Ice Slurry Ingestion on Risk-Taking Behavior in Healthcare Workers
Purpose: Healthcare workers (HCWs) wearing personal protective equipment (PPE) experience physiological strain that can impair motor and psychological functions, potentially affecting patient care. We assessed the effects of heat exposure on maximal strength and risk-taking behavior among PPE-wearing HCWs and the efficacy of ice slurry to alleviate adverse effects. Methods: Seventeen HCWS completed two experimental trials in a crossover design, consuming 5 g·kg−1 of body mass of ambient drink (AMB) or ice slurry (ICE) before donning PPE and undergoing 2 h of simulated decontamination exercise (wet-bulb globe temperature (WBGT): 25.9°C ± 0.8°C, PPE microenvironment WBGT: 29.1°C ± 2.1°C). Body core temperature (T c), heart rate (HR), chest skin temperature (T sk), ratings of perceived exertion (RPE), thermal sensation (RTS), maximal voluntary contraction (MVC), risk-taking behavior (balloon analogue risk-taking task (BART)), and salivary cortisol were assessed. Results: Predrinking to postdrinking ∆T c was greater in ICE (−0.2°C ± 0.1°C) than AMB (−0.0°C ± 0.1°C, P = 0.003). Post-drinking RTS was lower in ICE (2.7 ± 1.2) than AMB (4.1 ± 0.4, P < 0.001). ICE and AMB had similar T c and HR (both P > 0.05), but T sk was lower in ICE than AMB (P = 0.049). A lower MVC (30.3 ± 6.7 vs 27.4 ± 4.9 kg, P = 0.001) and higher BART-adjusted total pump count (472 ± 170 vs 615 ± 174 pumps, P = 0.017) was observed pretrial to posttrial in AMB but absent in ICE (both P > 0.05). Salivary cortisol was similar between trials (P = 0.42). Conclusions: Heat-exposed PPE-wearing HCWs had impaired maximal strength and elevated risk-taking behavior. This may increase the risk of avoidable workplace accidents that can jeopardize HCWs and patient care. Ice slurry ingestion alleviated these heat-related impairments, suggesting its potential as an ergogenic aid.
- 15 May 2024
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 56 (10) , 2016-2025
Open AccessEffects of Heat Exposure and Ice Slurry Ingestion on Risk-Taking Behavior in Healthcare Workers
Purpose: Healthcare workers (HCWs) wearing personal protective equipment (PPE) experience physiological strain that can impair motor and psychological functions, potentially affecting patient care. We assessed the effects of heat exposure on maximal strength and risk-taking behavior among PPE-wearing HCWs and the efficacy of ice slurry to alleviate adverse effects. Methods: Seventeen HCWS completed two experimental trials in a crossover design, consuming 5 g·kg−1 of body mass of ambient drink (AMB) or ice slurry (ICE) before donning PPE and undergoing 2 h of simulated decontamination exercise (wet-bulb globe temperature (WBGT): 25.9°C ± 0.8°C, PPE microenvironment WBGT: 29.1°C ± 2.1°C). Body core temperature (T c), heart rate (HR), chest skin temperature (T sk), ratings of perceived exertion (RPE), thermal sensation (RTS), maximal voluntary contraction (MVC), risk-taking behavior (balloon analogue risk-taking task (BART)), and salivary cortisol were assessed. Results: Predrinking to postdrinking ∆T c was greater in ICE (−0.2°C ± 0.1°C) than AMB (−0.0°C ± 0.1°C, P = 0.003). Post-drinking RTS was lower in ICE (2.7 ± 1.2) than AMB (4.1 ± 0.4, P < 0.001). ICE and AMB had similar T c and HR (both P > 0.05), but T sk was lower in ICE than AMB (P = 0.049). A lower MVC (30.3 ± 6.7 vs 27.4 ± 4.9 kg, P = 0.001) and higher BART-adjusted total pump count (472 ± 170 vs 615 ± 174 pumps, P = 0.017) was observed pretrial to posttrial in AMB but absent in ICE (both P > 0.05). Salivary cortisol was similar between trials (P = 0.42). Conclusions: Heat-exposed PPE-wearing HCWs had impaired maximal strength and elevated risk-taking behavior. This may increase the risk of avoidable workplace accidents that can jeopardize HCWs and patient care. Ice slurry ingestion alleviated these heat-related impairments, suggesting its potential as an ergogenic aid.