Yubin Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yubin Cho has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Joung Hwan Mun
Department of Bio-Mechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
3 shared publications - Oleksandr Yuhai
Department of Bio-Mechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
3 shared publications - Ahnryul Choi
Department of Biomedical Engineering, College of Medicine, Chungbuk National University, Cheongju 28644, Republic of Korea
2 shared publications - Hyunggun Kim
Department of Biomechatronic Engineering, Sungkyunkwan University, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 17 September 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 618
Machine Learning-Based Framework for Pre-Impact Same-Level Fall and Fall-from-Height Detection in Construction Sites Using a Single Wearable Inertial Measurement Unit
Same-level-falls (SLFs) and falls-from-height (FFHs) remain major causes of severe injuries and fatalities on construction sites. Researchers are actively developing fall-prevention systems requiring accurate SLF and FFH detection in construction settings prone to false positives. In this study, a machine learning-based approach was established for accurate identification of SLF, FFH, and non-fall events using a single waist-mounted inertial measurement unit (IMU). A total of 48 participants executed 39 non-fall activities, 10 types of SLFs, and 8 types of FFHs, with a dummy used for falls exceeding 0.5 m. A two-stage feature extraction yielded 168 descriptors per data window, and an ensemble SHAP-PFI method selected the 153 most informative variables. The weighted XGBoost classifier, optimized via Bayesian techniques, outperformed other current boosting algorithms. Using 5-fold cross-validation, it achieved an average macro F1-score of 0.901 and macro Matthews correlation coefficient of 0.869, with a latency of 1.51 × 10−3 ms per window. Notably, the average lead times were 402 ms for SLFs and 640 ms for FFHs, surpassing the 130 ms inflation time required for wearable airbags. This pre-impact SLF and FFH detection approach delivers both rapid and precise detection, positioning it as a viable central component for wearable fall-prevention devices in fast-paced construction scenarios.
- 17 September 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 618
Open AccessMachine Learning-Based Framework for Pre-Impact Same-Level Fall and Fall-from-Height Detection in Construction Sites Using a Single Wearable Inertial Measurement Unit
Same-level-falls (SLFs) and falls-from-height (FFHs) remain major causes of severe injuries and fatalities on construction sites. Researchers are actively developing fall-prevention systems requiring accurate SLF and FFH detection in construction settings prone to false positives. In this study, a machine learning-based approach was established for accurate identification of SLF, FFH, and non-fall events using a single waist-mounted inertial measurement unit (IMU). A total of 48 participants executed 39 non-fall activities, 10 types of SLFs, and 8 types of FFHs, with a dummy used for falls exceeding 0.5 m. A two-stage feature extraction yielded 168 descriptors per data window, and an ensemble SHAP-PFI method selected the 153 most informative variables. The weighted XGBoost classifier, optimized via Bayesian techniques, outperformed other current boosting algorithms. Using 5-fold cross-validation, it achieved an average macro F1-score of 0.901 and macro Matthews correlation coefficient of 0.869, with a latency of 1.51 × 10−3 ms per window. Notably, the average lead times were 402 ms for SLFs and 640 ms for FFHs, surpassing the 130 ms inflation time required for wearable airbags. This pre-impact SLF and FFH detection approach delivers both rapid and precise detection, positioning it as a viable central component for wearable fall-prevention devices in fast-paced construction scenarios.
- Open Access
Enhanced Three-Axis Frame and Wand-Based Multi-Camera Calibration Method Using Adaptive Iteratively Reweighted Least Squares and Comprehensive Error Integration
The accurate transformation of multi-camera 2D coordinates into 3D coordinates is critical for applications like animation, gaming, and medical rehabilitation. This study unveils an enhanced multi-camera calibration method that alleviates the shortcomings of existing approaches by incorporating a comprehensive cost function and Adaptive Iteratively Reweighted Least Squares (AIRLS) optimization. By integrating static error components (3D coordinate, distance, angle, and reprojection errors) with dynamic wand distance errors, the proposed comprehensive cost function facilitates precise multi-camera parameter calculations. The AIRLS optimization effectively balances the optimization of both static and dynamic error elements, enhancing the calibration’s robustness and efficiency. Comparative validation against advanced multi-camera calibration methods shows this method’s superior accuracy (average error 0.27 ± 0.22 mm) and robustness. Evaluation metrics including average distance error, standard deviation, and range (minimum and maximum) of errors, complemented by statistical analysis using ANOVA and post-hoc tests, underscore its efficacy. The method markedly enhances the accuracy of calculating intrinsic, extrinsic, and distortion parameters, proving highly effective for precise 3D reconstruction in diverse applications. This study represents substantial progression in multi-camera calibration, offering a dependable and efficient solution for intricate calibration challenges.
Open AccessEnhanced Three-Axis Frame and Wand-Based Multi-Camera Calibration Method Using Adaptive Iteratively Reweighted Least Squares and Comprehensive Error Integration
The accurate transformation of multi-camera 2D coordinates into 3D coordinates is critical for applications like animation, gaming, and medical rehabilitation. This study unveils an enhanced multi-camera calibration method that alleviates the shortcomings of existing approaches by incorporating a comprehensive cost function and Adaptive Iteratively Reweighted Least Squares (AIRLS) optimization. By integrating static error components (3D coordinate, distance, angle, and reprojection errors) with dynamic wand distance errors, the proposed comprehensive cost function facilitates precise multi-camera parameter calculations. The AIRLS optimization effectively balances the optimization of both static and dynamic error elements, enhancing the calibration’s robustness and efficiency. Comparative validation against advanced multi-camera calibration methods shows this method’s superior accuracy (average error 0.27 ± 0.22 mm) and robustness. Evaluation metrics including average distance error, standard deviation, and range (minimum and maximum) of errors, complemented by statistical analysis using ANOVA and post-hoc tests, underscore its efficacy. The method markedly enhances the accuracy of calculating intrinsic, extrinsic, and distortion parameters, proving highly effective for precise 3D reconstruction in diverse applications. This study represents substantial progression in multi-camera calibration, offering a dependable and efficient solution for intricate calibration challenges.
- Open Access
- 1 June 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (6) , 560
Deep-Learning-Based Recovery of Missing Optical Marker Trajectories in 3D Motion Capture Systems
Motion capture (MoCap) technology, essential for biomechanics and motion analysis, faces challenges from data loss due to occlusions and technical issues. Traditional recovery methods, based on inter-marker relationships or independent marker treatment, have limitations. This study introduces a novel U-net-inspired bi-directional long short-term memory (U-Bi-LSTM) autoencoder-based technique for recovering missing MoCap data across multi-camera setups. Leveraging multi-camera and triangulated 3D data, this method employs a sophisticated U-shaped deep learning structure with an adaptive Huber regression layer, enhancing outlier robustness and minimizing reconstruction errors, proving particularly beneficial for long-term data loss scenarios. Our approach surpasses traditional piecewise cubic spline and state-of-the-art sparse low rank methods, demonstrating statistically significant improvements in reconstruction error across various gap lengths and numbers. This research not only advances the technical capabilities of MoCap systems but also enriches the analytical tools available for biomechanical research, offering new possibilities for enhancing athletic performance, optimizing rehabilitation protocols, and developing personalized treatment plans based on precise biomechanical data.
- 1 June 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (6) , 560
Open AccessDeep-Learning-Based Recovery of Missing Optical Marker Trajectories in 3D Motion Capture Systems
Motion capture (MoCap) technology, essential for biomechanics and motion analysis, faces challenges from data loss due to occlusions and technical issues. Traditional recovery methods, based on inter-marker relationships or independent marker treatment, have limitations. This study introduces a novel U-net-inspired bi-directional long short-term memory (U-Bi-LSTM) autoencoder-based technique for recovering missing MoCap data across multi-camera setups. Leveraging multi-camera and triangulated 3D data, this method employs a sophisticated U-shaped deep learning structure with an adaptive Huber regression layer, enhancing outlier robustness and minimizing reconstruction errors, proving particularly beneficial for long-term data loss scenarios. Our approach surpasses traditional piecewise cubic spline and state-of-the-art sparse low rank methods, demonstrating statistically significant improvements in reconstruction error across various gap lengths and numbers. This research not only advances the technical capabilities of MoCap systems but also enriches the analytical tools available for biomechanical research, offering new possibilities for enhancing athletic performance, optimizing rehabilitation protocols, and developing personalized treatment plans based on precise biomechanical data.