CWChien-Wei Wang

Chien-Wei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chien-Wei Wang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fundamentals of Hand Anatomy

    by Chien-Wei Wang, Kevin C. Chung

  • Fundamentals of Rheumatoid Hand

    by Chien-Wei Wang, Kevin C. Chung

  • Fundamentals of Hand Examination

    by Chien-Wei Wang, Kevin C. Chung

  • Open Access

    Effects of Image Degradation on Deep Neural Network Classification of Scaphoid Fracture Radiographs: A Comparison of Different Noise Types (Preprint)

    by Chihung Lin, Alfred P. Yoon, Chien-Wei Wang, Tung Chao, Kevin C. Chung, Chang-Fu Kuo

    Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Deep learning models have shown strong potential for automated fracture detection on medical images. However, their robustness under varying image quality remains uncertain, particularly for small and subtle fractures such as scaphoid fractures. Understanding how different types of image perturbations affect model performance is crucial for ensuring reliable deployment in clinical practice. Objective: This study aimed to evaluate the robustness of a deep learning model trained to detect scaphoid fractures in radiographs when exposed to various image perturbations. We sought to identify which perturbations most strongly impact performance and to explore strategies to mitigate performance degradation. Methods: Radiographic datasets were systematically modified by applying Gaussian noise, blurring, JPEG compression, contrast-limited adaptive histogram equalization (CLAHE), resizing, and geometric offsets. Model accuracy was evaluated across different perturbation types and levels. Image quality was quantified using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) to assess correlations between degradation and model performance. Results: Model accuracy declined with increasing perturbation severity, but the extent varied across perturbation types. Gaussian blur caused the most substantial performance drop, whereas CLAHE increased the false-negative rate. The model demonstrated higher resilience to color perturbations than to grayscale degradations. A strong linear correlation was found between PSNR/SSIM and accuracy, suggesting that better image quality led to improved detection. Geometric offsets and pixel value rescaling had minimal influence, while resolution was the dominant factor affecting performance. Conclusions: The findings indicate that image quality, especially resolution and blurring, substantially influences the robustness of deep learning–based fracture detection models. Ensuring adequate image resolution and quality control can enhance diagnostic reliability. These results provide valuable insights for designing more accurate and resilient medical imaging models under real-world variability.


  • Are Observational Studies on Distal Radius Fracture Treatment Robust? An E-value Approach to Analysis

    by Chien-Wei Wang, William T. Bse Chung, Natalie B. Bse Baxter, Kevin C. Chung

    Background: Reported complication frequencies after distal radius fracture (DRF) treatment vary widely in the literature and are based mostly on observational evidence. Whether that evidence is sufficiently robust to use in practice is controversial. The E-value is an innovative sensitivity analysis that quantitates the robustness of observational evidence against unmeasured confounders, whereby a greater E-value usually implies more robust evidence and vice versa; with DRF complications, this approach can help guide readers to a more confident interpretation of the available evidence. Questions/purposes: In this study, we sought (1) to compare the complication frequencies among different DRF treatment modalities, and (2) to evaluate the robustness of these observational studies using the E-value as an index for unmeasured confounding. Methods: We searched PubMed, Embase, and SCOPUS for observational studies on the management of DRFs that were published from January 2001 to July 2021 with the last database search performed on July 31, 2021. All articles that compared different DRF treatment modalities with reported complication frequencies were included to accurately capture the quality of the observational studies in research about DRF. Risk ratios (RRs) of the overall complication and major complication risks were calculated for each subgroup comparison: volar plating versus dorsal plating, casting, external fixation, and percutaneous K-wire fixation. The RRs and their corresponding lower limits of the 95% confidence intervals (CIs) were used to derive the E-values. E-values can have a minimum possible value of 1, which signifies that the treatment-outcome association is not strong and can readily be overturned by unmeasured confounders. By contrast, a large E-value means that the observed treatment-outcome association is robust against unmeasured confounders. We averaged RRs and E-values for the effect estimates and lower limits of CIs across studies in each treatment comparison group. We identified 36 comparative observational studies that met the inclusion criteria. Seven studies compared volar with dorsal plating techniques. Volar plating was also compared with casting (eight studies), external fixation (15 studies), and percutaneous K-wire fixation (six studies). Results: Total and major complication risks did not differ among different DRF treatments. The mean RRs for total and major complications were 1.2 (95% CI 0.4 to 3.9; p = 0.74) and 1.8 (95% CI 0.4 to 11.4; p = 0.52) for the volar versus dorsal plating group; 1.2 (95% CI 0.3 to 11.2; p = 0.87) and 1.5 (95% CI 0.3 to 14.9; p = 0.74) for the volar plating versus casting group; 0.6 (95% CI 0.2 to 2.2; p = 0.33) and 0.8 (95% CI 0.2 to 6.7; p = 0.86) for the volar plating versus external fixation group; and 0.6 (95% CI 0.2 to 2.6; p = 0.47) and 0.7 (95% CI 0.2 to 4.0; p = 0.67) for the volar plating versus K-wire fixation group. The mean E-values for total and major complication frequencies for the between-group comparison ranged from 3.1 to 5.8; these were relatively large in the context of a known complication risk factor, such as high-energy impact (RR 3.2), suggesting a reasonable level of robustness against unmeasured confounding. However, the E-values for lower limits of CIs remained close to 1, which indicates the observed complication frequencies in these studies were likely to have been influenced by unmeasured confounders. Conclusion: Complication frequencies did not differ among different DRF treatment modalities, but the observed complication frequencies from most comparative observational studies were less robust against potential unmeasured confounders. The E-value method, or another type of sensitivity analysis, should be implemented in observational hand surgery research at the individual-study level to facilitate assessment of robustness against potential unmeasured confounders. Level of Evidence: Level III, therapeutic study.


  • Gate Voltages Impacting on Latch-up Measurements

    by Shao-Chang Huang, Jian-Hsing Lee, Chun-Chih Chen, Ching-Ho Li, Chih-Cherng Liao, Kai-Chieh Hsu, Gong-Kai Lin, Li-Fan Chen, Chien-Wei Wang, Chih-Hsuan Lin, et al.

    Integrated Circuits (ICs) are often turned off under latch-up measurements. One power IC is often applied with a large size for driving capabilities. The large size device is often difficult to be turned off under latch-up stresses. In this paper, device behaviors of different gate biased voltages applied on large size devices under latch-up measurements are discussed. From the silicon data analyses, latch-up current paths changed from MOSFET to the parasitic diodes are observed well so the false latch-up test is verified. Finally, over voltage test is proposed for turned-on large size devices' latch-up measurements.


  • EOS Endurance Power Circuits without Depletion Mode Devices

    by Shao-Chang Huang, Jian-Hsing Lee, Ching-Ho Li, Sue-Yi Chen, Chih-Hsuan Lin, Chun-Chih Chen, Li-Fan Chen, Gong-Kai Lin, Chien-Wei Wang, Kai-Chieh Hsu, et al.

    Electrical Overstress (EOS) avoiding power integrated circuits (ICs) are often designed with depletion mode NMOSFET. In some applications, there can be no depletion mode NMOSFETs. From device normal operations and EOS analyses, new circuits without depletion mode devices are successfully proposed for approaching device typical operations and EOS endurances.