Pengju Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pengju Li has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
- Bozhi Tian
The James Franck Institute, University of Chicago, Chicago, USA
19 shared publications - Jing Zhang
The James Franck Institute, University of Chicago, Chicago, USA
8 shared publications - Chuanwang Yang
The James Franck Institute, The University of Chicago, Chicago, USA
7 shared publications Saehyun Kim
Department of Chemistry, The University of Chicago, Chicago, USA
6 shared publications- Wen Li
Department of Chemistry, University of Chicago, Chicago, USA
4 shared publications Ananth Kamath
The James Franck Institute, The University of Chicago, Chicago, IL 60637, USA
3 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by Springer Nature in Nature Biomedical Engineering
- p. 1
Author Correction: Biomimetic graphitic carbon nitride nanoparticles for multiscale photomodulation and therapeutic intervention
- 12 October 2026
- Published by Springer Nature in Nature Biomedical Engineering
- p. 1
Open AccessAuthor Correction: Biomimetic graphitic carbon nitride nanoparticles for multiscale photomodulation and therapeutic intervention
- Open Access
- 22 September 2026
- Published by Springer Nature in Nature Biomedical Engineering
- p. 1-21
Biomimetic graphitic carbon nitride nanoparticles for multiscale photomodulation and therapeutic intervention
Most organic matter on Earth originates from the conversion of solar energy through photosynthesis in chloroplasts. Here, drawing inspiration from photosynthesis, we develop hollow-sphere graphitic carbon nitride nanoparticles (hg-C3N4 NPs) that can modulate biological activity from subcellular processes to whole‑tissue function. The homogeneous hg-C3N4 NPs show responsiveness to light via both photoelectrochemical and photothermal mechanisms and can be spontaneously internalized with excellent cytocompatibility. Using a focusing laser, the hg-C3N4 NPs enable intracellular optical stimulation with subcellular resolution, inducing calcium-transient release in multiple cells and propagation in primary cardiomyocytes and cardiac fibroblasts. At the multicellular scale, optical pacing and synchronization of cardiomyocyte beating is readily achieved by light-emitting diodes. Further, we demonstrate that hg-C3N4 nanoparticles can be safely delivered and elicit measurable cortical and behavioural light responses in a model of advanced retinal degeneration. The application of hg-C3N4 NPs to porcine retinal tissue ex vivo confirms their modulation capability to directly activate retinal ganglion cell activity under light-emitting diode photostimulation. Taken together, hg-C3N4 NPs represent a versatile tool to address complex biomedical challenges through subcellular, intercellular and tissue-level photo-modulation.
- 22 September 2026
- Published by Springer Nature in Nature Biomedical Engineering
- p. 1-21
Open AccessBiomimetic graphitic carbon nitride nanoparticles for multiscale photomodulation and therapeutic intervention
Most organic matter on Earth originates from the conversion of solar energy through photosynthesis in chloroplasts. Here, drawing inspiration from photosynthesis, we develop hollow-sphere graphitic carbon nitride nanoparticles (hg-C3N4 NPs) that can modulate biological activity from subcellular processes to whole‑tissue function. The homogeneous hg-C3N4 NPs show responsiveness to light via both photoelectrochemical and photothermal mechanisms and can be spontaneously internalized with excellent cytocompatibility. Using a focusing laser, the hg-C3N4 NPs enable intracellular optical stimulation with subcellular resolution, inducing calcium-transient release in multiple cells and propagation in primary cardiomyocytes and cardiac fibroblasts. At the multicellular scale, optical pacing and synchronization of cardiomyocyte beating is readily achieved by light-emitting diodes. Further, we demonstrate that hg-C3N4 nanoparticles can be safely delivered and elicit measurable cortical and behavioural light responses in a model of advanced retinal degeneration. The application of hg-C3N4 NPs to porcine retinal tissue ex vivo confirms their modulation capability to directly activate retinal ganglion cell activity under light-emitting diode photostimulation. Taken together, hg-C3N4 NPs represent a versatile tool to address complex biomedical challenges through subcellular, intercellular and tissue-level photo-modulation.
- 5 September 2026
- Published by Springer Nature
- p. 1-12
Fabrication of Heterogeneous Silicon-Based Mesostructures
- 5 September 2026
- Published by Springer Nature
- p. 1-12
Fabrication of Heterogeneous Silicon-Based Mesostructures
- 24 June 2026
- Published by Springer Nature in Nature Photonics
- Vol. 20 (8) , 950-960
Self-organized nanoplasmonic artificial leaf for hot-carrier bioelectronic interfaces
Without discrete pixels or wired leads, natural plant leaves respond to light and relay electrochemical signals to surrounding tissues through nanoscale chlorophyll-containing protein complexes - an elegant capability sought in next-generation leadless optoelectronic systems. Although semiconductors and their heterojunctions are commonly employed to mimic photosynthesis, nanoplasmonic structures offer a largely untapped alternative. Harnessing plasmonic hot carriers for macroscopic systems remains challenging, limiting applications in tissue-level neuromodulation and human-machine interfaces. We introduce a hot-carrier artificial leaf optoelectronic device, formed by thermally self-organized 3D gold–titanium dioxide units on ultrathin membranes. These nanoplasmonic interfaces enhance visible-light optoelectronic responsiveness at sub-100-nm thickness, support highly localized hot-carrier injection, and exhibit stable, linear performance over a wide range of light intensities, overcoming the material, bandgap, and carrier diffusion limits of conventional semiconductors. The resulting nanoplasmonic devices enable leadless, multimodal optoelectronic modulation and pixel-less optical pattern recognition, presenting a potentially scalable platform for hot carrier-enabled biomedical, nanophotonic, and human-machine interface technologies.
- 24 June 2026
- Published by Springer Nature in Nature Photonics
- Vol. 20 (8) , 950-960
Self-organized nanoplasmonic artificial leaf for hot-carrier bioelectronic interfaces
Without discrete pixels or wired leads, natural plant leaves respond to light and relay electrochemical signals to surrounding tissues through nanoscale chlorophyll-containing protein complexes - an elegant capability sought in next-generation leadless optoelectronic systems. Although semiconductors and their heterojunctions are commonly employed to mimic photosynthesis, nanoplasmonic structures offer a largely untapped alternative. Harnessing plasmonic hot carriers for macroscopic systems remains challenging, limiting applications in tissue-level neuromodulation and human-machine interfaces. We introduce a hot-carrier artificial leaf optoelectronic device, formed by thermally self-organized 3D gold–titanium dioxide units on ultrathin membranes. These nanoplasmonic interfaces enhance visible-light optoelectronic responsiveness at sub-100-nm thickness, support highly localized hot-carrier injection, and exhibit stable, linear performance over a wide range of light intensities, overcoming the material, bandgap, and carrier diffusion limits of conventional semiconductors. The resulting nanoplasmonic devices enable leadless, multimodal optoelectronic modulation and pixel-less optical pattern recognition, presenting a potentially scalable platform for hot carrier-enabled biomedical, nanophotonic, and human-machine interface technologies.
- Open Access
- 1 June 2026
- Published by IOP Publishing in Nano Futures
- Vol. 10 (2) , 022001
Nano-enabled living materials and living electronics: a roadmap for innovation and impact
Nano-enabled living materials and living electronics represent the next frontier in integrating biology with advanced nanotechnology, offering unprecedented opportunities to design systems with programmable, adaptive, and multifunctional capabilities. By combining living cells or tissues with engineered nanostructures, living materials and electronics create platforms for bi-directional communication, sensing, and actuation. These advancements hold immense potential for applications in healthcare, energy systems, and environmental sustainability. This roadmap provides a comprehensive vision for advancing this transformative field, addressing scientific challenges, technological pathways, and long-term goals for deploying these hybrid systems at scale.
- 1 June 2026
- Published by IOP Publishing in Nano Futures
- Vol. 10 (2) , 022001
Open AccessNano-enabled living materials and living electronics: a roadmap for innovation and impact
Nano-enabled living materials and living electronics represent the next frontier in integrating biology with advanced nanotechnology, offering unprecedented opportunities to design systems with programmable, adaptive, and multifunctional capabilities. By combining living cells or tissues with engineered nanostructures, living materials and electronics create platforms for bi-directional communication, sensing, and actuation. These advancements hold immense potential for applications in healthcare, energy systems, and environmental sustainability. This roadmap provides a comprehensive vision for advancing this transformative field, addressing scientific challenges, technological pathways, and long-term goals for deploying these hybrid systems at scale.
- 15 April 2026
- Published by Springer Nature in Nature Materials
- Vol. 25 (10) , 1701-1717
Minimally invasive bioelectronic implants
Bioelectronic implants enable therapeutic and diagnostic intervention of physiological systems by interfacing electronic devices with living tissues. However, conventional implant strategies often require highly invasive surgical procedures, such as thoracotomies and craniotomies, motivating the development of minimally invasive bioelectronic systems that can be precisely deployed and operated while reducing tissue trauma, recovery time and long-term complications. This Review highlights recent advancements in minimally invasive bioelectronic systems within specified anatomical sites. Originating from techniques used in stent and catheter development, current bioelectronic platforms are now designed with a dual focus on optimizing macroscale ergonomics and achieving seamless integration with the dynamic internal biological environment. Recent innovations include miniaturized neural probes, optoelectronic cardiac pacemakers and bioadhesive cardiac pacing leads. These devices use advanced materials, including shape-memory alloys, programmable polymers and dynamic actuators, to combine structural versatility with multifunctional performance. Looking ahead, emerging designs are expected to leverage retrievable implants, expandable occluders and responsive structures that enable facile deployment and superior adaptation to tissue motion, thereby reducing mechanical mismatch and enhancing long-term biocompatibility. By advancing minimally invasive delivery and patient-specific design, bioelectronics is positioned to enable more effective and personalized clinical interventions.
- 15 April 2026
- Published by Springer Nature in Nature Materials
- Vol. 25 (10) , 1701-1717
Minimally invasive bioelectronic implants
Bioelectronic implants enable therapeutic and diagnostic intervention of physiological systems by interfacing electronic devices with living tissues. However, conventional implant strategies often require highly invasive surgical procedures, such as thoracotomies and craniotomies, motivating the development of minimally invasive bioelectronic systems that can be precisely deployed and operated while reducing tissue trauma, recovery time and long-term complications. This Review highlights recent advancements in minimally invasive bioelectronic systems within specified anatomical sites. Originating from techniques used in stent and catheter development, current bioelectronic platforms are now designed with a dual focus on optimizing macroscale ergonomics and achieving seamless integration with the dynamic internal biological environment. Recent innovations include miniaturized neural probes, optoelectronic cardiac pacemakers and bioadhesive cardiac pacing leads. These devices use advanced materials, including shape-memory alloys, programmable polymers and dynamic actuators, to combine structural versatility with multifunctional performance. Looking ahead, emerging designs are expected to leverage retrievable implants, expandable occluders and responsive structures that enable facile deployment and superior adaptation to tissue motion, thereby reducing mechanical mismatch and enhancing long-term biocompatibility. By advancing minimally invasive delivery and patient-specific design, bioelectronics is positioned to enable more effective and personalized clinical interventions.
- 15 August 2025
- Published by Springer Nature in Nature Chemical Engineering
- Vol. 2 (8) , 484-497
Hydrogen evolution and dynamics in hydrogel electrochemical cells for ischemia–reperfusion therapy
Molecular hydrogen (H2) protects organs from reactive oxygen species damage associated with ischemia–reperfusion (I/R) injury. Existing H2 delivery methods, such as gas inhalation and H2-rich water consumption, target the entire body and experience leakage during administration. Here we engineer a portable hydrogel electrochemical cell that enables on-demand H2 production via the hydrogen evolution reaction. The system enables H2 controlled generation, localized storage and sustained diffusion to the tissue–device interface, with better controllability and sustainability. We conduct a thorough study of H2 evolution and dynamics in the hydrogel system, evaluating the influence of hydrogel polymer composition on the hydrogen evolution reaction kinetics, bubble morphologies and storage. We validate its protective effects (1) in vitro with cardiomyocytes and keratinocytes, (2) ex vivo in I/R hearts and (3) in vivo in skin I/R pressure ulcers. These findings demonstrate the potential of the hydrogel electrochemical cell design for efficient and sustainable H2 delivery in I/R therapy, which could be broadly applied in other gas-based therapies and drug delivery research.
- 15 August 2025
- Published by Springer Nature in Nature Chemical Engineering
- Vol. 2 (8) , 484-497
Hydrogen evolution and dynamics in hydrogel electrochemical cells for ischemia–reperfusion therapy
Molecular hydrogen (H2) protects organs from reactive oxygen species damage associated with ischemia–reperfusion (I/R) injury. Existing H2 delivery methods, such as gas inhalation and H2-rich water consumption, target the entire body and experience leakage during administration. Here we engineer a portable hydrogel electrochemical cell that enables on-demand H2 production via the hydrogen evolution reaction. The system enables H2 controlled generation, localized storage and sustained diffusion to the tissue–device interface, with better controllability and sustainability. We conduct a thorough study of H2 evolution and dynamics in the hydrogel system, evaluating the influence of hydrogel polymer composition on the hydrogen evolution reaction kinetics, bubble morphologies and storage. We validate its protective effects (1) in vitro with cardiomyocytes and keratinocytes, (2) ex vivo in I/R hearts and (3) in vivo in skin I/R pressure ulcers. These findings demonstrate the potential of the hydrogel electrochemical cell design for efficient and sustainable H2 delivery in I/R therapy, which could be broadly applied in other gas-based therapies and drug delivery research.
- 31 July 2025
- Published by MyJove Corporation
- No. 221,p. e68305
JoVE Video Dataset
Electrophysiological studies are pivotal in exploring interactions between materials and cardiac biointerfaces. Recent advancements have introduced various novel conductor and semiconductor materials for bidirectional interfaces with cardiac models, facilitating low-intensity pacing alongside high spatiotemporal and high signal-to-noise ratio (SNR) recordings. The ex vivo rodent heart model serves as an effective platform for validating the functionalities of new materials and devices, bridging in vitro findings to translational insights while minimizing ethical and administrative concerns. In this protocol, we detail the isolation and ex vivo perfusion of adult rat hearts using a Langendorff apparatus, establishing precise bidirectional stimulation and recording with high-performance semiconductors and conductors, including nanoporous silicon, nanoporous carbon, and flexible mesh-like microelectrode arrays. Additionally, we present a myocardial infarction model induced by ischemia-reperfusion (I/R) injury, assessed through multichannel recording and mapping as well as infarct staining, enabling cardiac disease-relevant studies and potential therapeutic explorations. This methodology offers valuable insights into materials-bio interface research and the development of next-generation cardiac bioelectronics.
- 31 July 2025
- Published by MyJove Corporation
- No. 221,p. e68305
JoVE Video Dataset
Electrophysiological studies are pivotal in exploring interactions between materials and cardiac biointerfaces. Recent advancements have introduced various novel conductor and semiconductor materials for bidirectional interfaces with cardiac models, facilitating low-intensity pacing alongside high spatiotemporal and high signal-to-noise ratio (SNR) recordings. The ex vivo rodent heart model serves as an effective platform for validating the functionalities of new materials and devices, bridging in vitro findings to translational insights while minimizing ethical and administrative concerns. In this protocol, we detail the isolation and ex vivo perfusion of adult rat hearts using a Langendorff apparatus, establishing precise bidirectional stimulation and recording with high-performance semiconductors and conductors, including nanoporous silicon, nanoporous carbon, and flexible mesh-like microelectrode arrays. Additionally, we present a myocardial infarction model induced by ischemia-reperfusion (I/R) injury, assessed through multichannel recording and mapping as well as infarct staining, enabling cardiac disease-relevant studies and potential therapeutic explorations. This methodology offers valuable insights into materials-bio interface research and the development of next-generation cardiac bioelectronics.
- 18 July 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 221,p. e68305
Bidirectional Electrical and Optoelectronic Interfaces in Healthy and Ischemic Ex Vivo Rat Hearts
Electrophysiological studies are pivotal in exploring interactions between materials and cardiac biointerfaces. Recent advancements have introduced various novel conductor and semiconductor materials for bidirectional interfaces with cardiac models, facilitating low-intensity pacing alongside high spatiotemporal and high signal-to-noise ratio (SNR) recordings. The ex vivo rodent heart model serves as an effective platform for validating the functionalities of new materials and devices, bridging in vitro findings to translational insights while minimizing ethical and administrative concerns. In this protocol, we detail the isolation and ex vivo perfusion of adult rat hearts using a Langendorff apparatus, establishing precise bidirectional stimulation and recording with high-performance semiconductors and conductors, including nanoporous silicon, nanoporous carbon, and flexible mesh-like microelectrode arrays. Additionally, we present a myocardial infarction model induced by ischemia-reperfusion (I/R) injury, assessed through multichannel recording and mapping as well as infarct staining, enabling cardiac disease-relevant studies and potential therapeutic explorations. This methodology offers valuable insights into materials-bio interface research and the development of next-generation cardiac bioelectronics.
- 18 July 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 221,p. e68305
Bidirectional Electrical and Optoelectronic Interfaces in Healthy and Ischemic Ex Vivo Rat Hearts
Electrophysiological studies are pivotal in exploring interactions between materials and cardiac biointerfaces. Recent advancements have introduced various novel conductor and semiconductor materials for bidirectional interfaces with cardiac models, facilitating low-intensity pacing alongside high spatiotemporal and high signal-to-noise ratio (SNR) recordings. The ex vivo rodent heart model serves as an effective platform for validating the functionalities of new materials and devices, bridging in vitro findings to translational insights while minimizing ethical and administrative concerns. In this protocol, we detail the isolation and ex vivo perfusion of adult rat hearts using a Langendorff apparatus, establishing precise bidirectional stimulation and recording with high-performance semiconductors and conductors, including nanoporous silicon, nanoporous carbon, and flexible mesh-like microelectrode arrays. Additionally, we present a myocardial infarction model induced by ischemia-reperfusion (I/R) injury, assessed through multichannel recording and mapping as well as infarct staining, enabling cardiac disease-relevant studies and potential therapeutic explorations. This methodology offers valuable insights into materials-bio interface research and the development of next-generation cardiac bioelectronics.
- Open Access
- 21 May 2025
- Published by Springer Nature in Nature Chemical Engineering
- Vol. 2 (5) , 321-333
Airborne biomarker localization engine for open-air point-of-care detection
- 21 May 2025
- Published by Springer Nature in Nature Chemical Engineering
- Vol. 2 (5) , 321-333
Open AccessAirborne biomarker localization engine for open-air point-of-care detection